Loading...
HomeMy WebLinkAboutResolution - 2065 - Contract - CB Anderson Electric - Materials & Equipment, 2 Substations - 06/14/1985DGV:cl RESOLUTION Resolution #2065 June 14, 1985 Agenda Item #49 BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF LUBBOCK: THAT the Mayor of the City of Lubbock BE and is hereby authorized and directed to execute for and on behalf of the City of Lubbock a Contract with C.B. Anderson Electric Company for materials and equipment for McDonald Substation and Vicksburg Substation, attached herewith, which shall be spread upon the minutes of the Council and as spread upon the minutes of this Council shall constitute and be a part of this Resolution as if fully copied herein in detail. Passed by the City Council this 14th day of June , 1985. ALAN flENRYv MAYOR ATTEST: Renet`te Boyd, City 5ecretary APPROVED AS TO CONTENT: Carroll McDonald, Director of Electric Utilities APPROVED AS TO FORM: . Vandiver, First Assistant City Attorney PASSED AND APPROVED THIS 23rd DAY OF MAY, 1985. Ala enry, yor ATTEST: , city Secrietar APPROVED AS TO CONTENT: arry :Hof. a Director of Transportation APPROVED AS TO FORM: glk,4, G e.ln Ross Jr., City Attorney SPECIFICATION #SE -00104-3-032585 McDONAID SUBSTATION AND SPECIFICATION #SE -00105-3-032585 VICKSBURG SUBSTATION INDEX NOTICE TO BIDDERS PAYMENT BOND PERFORMANCE BOND ADVERTISEMENT INSTRUCTION TO BIDDERS GENERAL CONDITIONS • CONTACT AGREEMENT SPECIFICATIONS TAB 1. Air Break Switch - " TAB 2. Steel . TAB 3. Bus Pipe " TAB 4. Insulators 40<71 ! TAB 5. Control Cable " TAB 6. Grounding TAB 7. Lightning Arresters TAB 8. Potential Transformers TAB 9. Drawing NOTICE TO BIDDERS . BID # 8494 Sealed proposals addressed to Gene Eads, Purchasing Manager, City of Lubbock, Texas, will be received at the office of the Purchasing Manager, 1625 13th St., Room L-04, Lubbock, Texas, 79401, until 2:00" o'clock p.m. on the 7th day of May, 1985, to furnish all labor and materials and perform all work for the construction of the following described project: HATE RI ALS,".1ND-`EQ.UIPMENT FOR MCDONALD AND VICKSBURG SUBSTATIONS After the expriration of -the time and date above first written, said-..- sealed aid `"sealed proposals will:b.e__opened by the Purchasing Manager at his office and publicly read. aloud. It is the sole responsibility of the bidder to insure that his bid is actually in the:.,.office of Gerre Eads, Purchasing Manager for the City of Lubbock, prior to the expiration of the date above first written. The City Council will consider the bids on the 23rd day of May, 1985, at Municipal Bldg., Lubbock, Texas, or as soon thereafter as may be reasonably convenient, subject to the right to reject any or all bids and waive any formalities. The successful bidder will be required to furnish a performance bond and payment bond in accordance with Article 5160, Vernon's Ann. Civil St., in the amount of 100% of the total contract price in the event that said contract price exceeds $25,000.00. If the contract price does not exceed $25,000.00 the said statutory bonds will not be required. Bidders are required, whether or not a payment or performance bond is required, to submit a cashier's or certified check issued by a bank satisfactory to the City or -Lubbock, or a proposal bond from a reliable surety company, payable without recourse to the order of the City of Lubbock in an amount not less than 5% of the total -amount of the bid submitted as a guarantee that bidder will enter into -a contract and execute all necessary bonds (if required) within 10 days after notice of award of the contract to him. a.. PAYMENT BOND (Applicable on all contracts in excess of $25,000) (To be used in Texas under Y.A.T.S. 5160) THE STATE OF COUNTY OF KNOW ALL MEN BY THESE ?RESENT: That we (1) . (2) of hereinafter called Principal and (3) of , State of hereinafter called the Surety, are held and firmly bound unto (4) of , hereinafter called. Owner, and unto all -persons, firms, and corporations who may furnish materials for, or perform labor upon the building or improvements hereinafter referred to in the penal sum of ($ ) dollars in lawful money of the United States, to be paid in (5). , for the payment of which sum well and truly to be made, we bind ourselves, our heirs, executors, administrators and successors, jointly and severally, firmly by these presents. TETE CONDITION OF THIS OBLIGATION is such that Whereas, the Principal .• entered into a certain contract with-(6)- The ith-(6)The Owner, dated the day of , A.D. 19 , a. copy of which -is hereto attached and made a part hereof, for the construction of: NOW, THEREFORE, the condition of this obligation is such that, if the Principal shall promptly make payment to all claimants as defined in Article 5160 Revised Civil Statutes of Texas, 1925, as amended by House Bill 344, Acts 56th Legislature, Regular Session, 1959, effective April 27, 1959, and as • further amended by Acts 1969, 61st Legislature, p. 1390; ch'. 422 Sect. 1, effective June 2, 1969, supplying labor and materials in the prosecution of. • the work provided for in said contract, then this obligation shall be null and void, otherwise it shall -remain -in full' -force and effect. • This bond is made and entered into solely for the protection of all ;J: claimants supplying labov and materials in the prosecution of the work provided for in said contract, and'all such claimants shall have a direct right of action under the bond as provided in Artic1e:5160, Revised Civil Statutes 1925, as amended by House Bill 344, Acts 56th, Legislature, Regular Session, 1959, and as further amended by Acts 1969, 61st Legislature, p. 1390, ch. 422, Sect. 1, effective June 2, 1969. PROVIDED FURTHER, that if any legal action be filed upon this bond, venue shall lie County, State of Texas, and that 'the said sureyt, for value received hereby stipulates and agrees that no change, extension of. time, alteration or addition to the terms of the contract or to the work to be performed thereunder or the specifications accompanying the same shall in any wise affect its obligation on this bond, and it does hereby waive notice of any such change, extension of time, alteration or addition to the terms of the contract or to the work -or to the specifications. PROVIDED FURTHER, that no final settlement between the Owner and the Contractor shall abridge the right of any beneficiary hereunder, whose claim may be unsatisfied. IN WITNESS WHEREOF, this instrument is executed in six counterparts, each one of which shall be deemed an original, this the day of , A.D. 19 Principal ATTEST: (Principal) Secretary By (SEAL) Witness as to Principal (Address) (Address) ATTEST: . Surety (Surety) Secretary BY ` ` (SEAL) (Address) Witness as to Surety. NOTE: If Contractor i 'Partnership, all partner should execute bond. (Address) These footnotes refer.to the numbers in body of contract above: Date of Bond must not be prior to date of contract (1) Correct name of Contractor (4) Correct Name of Owner (2) A Corporation, a Partnership or an (5) County and State = Individual, as case may be (6) Owner (3) Correct -Name -of Surety r . PERFORii4NCE BOND (Applicable on all contracts in excess of $25,000) (To be used in Texas under V.A.T.S. 5160) THE STATE OF COUNTY OF KNOW ALL MEN BY THESE PRESENT: that we (1) a (2) of _ hereinafter called Principal and (3) of , State of , hereinafter called the Surety, are held and firmly bound into (4) of hereinafter' callgd Owner, in the penal sum of ($ ) Dollars in lawful money of the United States, to be paid in (5) for the payment of which sum well and truly to be made, we bind ourselves, our heirs, executors, administrators and successors, jointly and severally, firmly _ by these presents. THE CONDITION OF THIS OBLIGATION is such that Whereas, the. Principal entered into a certain contract with (6) the Owner, dated the day of , A. D. 19 , a copy of which is hereto attached and made .a part hereof for the construction of: (herein called the.. "work") These footnotes refer to the numbers in body -of contract above: Date of Bond must not be prior to date of Contract (1) -Correct name of Contractor (2) A _Corporation, a Partnership or•an Individual, as case may be (3) - Correct name of -Surety (4) Correct -name of Owner (5) County and --State (6) Owner Texas rerioi-.:._�_uce tonal t NOW THEREFORE, if the Principal shall well, truly and faithfully perform the work in accordance with the plans, specifications and contract documents during the original term thereof, and any extensions thereof which may be granted by the Owner, with or without notice to the Surety, and if he shall satisfy all claims and demands' incurred under such contract, and shall fully idemnify and save harmless the Owner from all costs and damages which it may suffer by reason of failure to do so, and shall reimburse and repay the Owner all outlay and expense which the Owner may incur in making good any default, then this obligation shall be void; otherwise to remain in full force and effect. r PROVIDED FURTHER, that if any legal action be filed upon this bond, venue shall lie County, State of Texas, and that the said surety, for value received hereby stipulates and agrees that no change, extension of time, alteration or addition to the terms of the contract or to the work to be performed thereunder or the specifications accompanying the same shall in any wise affect its obligation on this bond, and it does hereby waive notice of any such change, extension of time, alteration or. addition to the terms of the contract or to the work or to the specifications." IN WITNESS WHEREOF, this instrument is executed in six counterparts, each one of which shall be deemed an original, this the day of A.D. - Principal ATTEST: - BY (Principal) Secretary (SEAL) (Address)` Witness as to Principal ADVERT I SEME14T _ FOR STEEL AND MISCELLANEOUS EQUIPMENT FOR McDONALD SUBSTATION AND VICKSBURG-SUBSTATION Sealed bids will be received in the office of Gene Eads, City Purchasing Director, Lubbock, Texas, prior to M. on , 19 and publicly opened immediately there- after on the same date for: STEEL AND MISCELLANEOUS EQUIPMENT FOR McDONALD SUBSTATION AND VICKSBURG SUBSTATION complete in accordance with Specification #SE 00104-3-032585 and Specification DISE-00105-3-032585, and. the- InstructionsAo Bidders. It is the sole responsibility of the Bidder -Lo insure that -his bid is actually in the office of Gene Eads prior to the above described closing time. -The advertisement -for bids --.is by the .City of -Lubbock, Texas, for its municipally owned electric utility, Lubbock Power and Light. Any reference to Lubbock Power and Light shall be construed to mean the City of Lubbock, Texas. INSTRUCTIONS TO BIDDERS A. All bids must be quoted on the white document entitled "City of Lubbock Request for Quotation". Such document must be signed by the Bidder. B- These specifications #SE -00104-3-032585 and #SE-0010 and be attached to all bids. Such specifications will forms a5parttof'thepany contract entered into between the City of Lubbock and the successful Bidder. C. Each bid shall be enclosed in a sealed envelope, addressed to Gene Eads, City Purchasing Director, Lubbock, Texas, and endorsed on the outside of the envelope in the following manner: (a) Bidder's name (b) Proposal for: steel and misceallaneous equipment for McDonald Substation and Vicksburg Substation D. Proposals may be withdrawn and resubmitted at any time prior to the time • set for the opening of the bids, but no proposal may be withdrawn or altered thereafter. E. The City -of Lubbock reserves the right to reject any and all.bids, or parts of bids, and to waive irregularities and informalities in any bid submitted. F. Each bidder shall thoroughly and fully inform himself of all factors*`: which would affect_the.:prosecution and completion of the work and cost thereof. It shall be understood and agreed that all such factors have been investigated and considered in the preparation of every proposal. submitted. There shall be no subsequent financial adjustment to any contract awarded which is based on the lack of such prior information or its effect on the Cost, - of - the work. G. All sheets of the -Instructions to Bidders, proposal forms, Contract Agreement, General Conditions, and Specifications shall be bound and contained together when submitted and filed with the City of Lubbock, Texas. Such sheets shall be part of the contract' awarded. H. Exceptions to the specifications shall be kept to a minimum, however, if exceptions are taken by the Bidder to the specifications, they shall be clearly and completely noted on a separate attachment. Exceptions taken elsewhere shall not be considered as a part of the bid or subsequent contracts. If any conflict arises between the specifications and the Bidder's proposal (other .than. exceptions duly noted), the specifications shall.govern. I. All bids must -be _quoted.-F.O..B.. - Lubbock, Texas. GENERAL CONDITIONS A. The contract awarded to the successful Bidder shall be construed by -and governed by the laws of the State of Texas. B. No payments made or certificates -given shall be considered as conclusive' evidence of the performance of the Contract, either wholly or in part, nor shall any certificate or payment be construed as acceptance of defective materials, parts, systems, or work. Neither the final payment nor certificate nor any provision in the Contract shall relieve the Bidder of responsibility for faulty materials or workmanship, and -he shall remedy any defects -due thereto and pay for any damage to other materials or work resulting therefrom, which shall appear within a period of one year from the date the system is 'placed in commercial operation. C. All bidders shall attach 'to the bid a copy of their current pricing policy. This pricing policy will remain in effect for the:term.of this bid. Alter— .nate .pricing is acceptable; succi as bidding at a firm price in addition to a bid based on an escalation clause.If the prices are subject to an escalation clause, the base indices to be used are as, follows: Labor , Steel , Copper Products , and Oil -(Monthly Labor. "Review publication February; 1983).. We will accept .a statement of maximum escalation._ Bids will be evaluated. on the basis of compliance with speci— fications, price, delivery, and operational experience with bidders products. 3.= ` Ick _ � - CO:;TRACT AGR£EME1%T (EQUIPATENT) THIS AGREEIMENT, made and entered into this 24 -- day of 199-7 by and between The City of Lubbock, Texas acting through its TTayor and City.Counci] thereunto duly authorized so to do, Party of the First Part, and hereinafter called the Purchaser, and C R_ Andprcnn Flertrir Company a Corporation_ of Oklahoma Party of the Second Part, and hereinafter called the Contractor. WITNESSETH: THAT WHEREAS, the Purchaser has caused to be prepared, in accordance with law, specifications, plans, and other contract documents for the work herein described, and has approved and adopted said documents, and has caused to be published, in the manner and for the time required by law, an advertisement for and in connection with acquiring in accordance with the terms of this Contract; and WHEREAS, the said Contractor, in response to such advettisement, has submitted to the Purchaser, in the manner and at the time specified, a sealed proposal in accordance with the terms of said advertisement; and WHEREAS, the -Purchaser, in the manner prescribed by law, has publicly opened, examined, and canvassed .the proposals submitted in response to the published invitation therefor, and as -a result of such canvass has determined and declared the aforesaid 'Contractor to be the best'bidder for the said work and has duly awarded to the said Contractor a contract therefor, for the sum or sums named in the Contractor's proposal, a copy thereof*.being attached to and made a part of this Contract. NOW THEREFORE, inconsideration of :the compensation to be paid to the Contractor and of the mutual agreements herein contained, the -Parties -to these presents have agreed and .hereby agree, the Purchaser 'for itself and its successors and the Contractor for itself, himself,.or themselves, or -its, his,.or_their successors __and_assigns, or its, his, or"their executors and administrators, as follows:. ARTICLE 1. That the Contractor shall (a) "Furnish all materials,. supplies, and equipment specified 'and required to be incorporated in and form a permanent part of the completed work; (b) Provide and perform all necessary work; and, in a good, substantial, and workmanlike manner and in accordance with -the provisions of the General Conditions, and the Instructions to Bidders, (which .are attached hereto and made- a -part - hereof) --and °in conformity with -the Specifications Number I. (c)_Execute and complete all work included in and covered by the Purchaser'_s official award .of this Cbntract to the said_Contractor; such -awaiU being,based-on the acceptance by the Purchaser of the Contractor's proposal, or .part thereof, as follows: inat tC,E t°urrhager shall pati perforWaof to the Contractor for the accept assJull the Lurk erbraced in this Contract and the Contractor will compensation therfor, the sum (subject to adustment as pro- vided by the Contract) of j a for all work covered by and included in -the (ConEract award and desi n ) the foregoing Article 1. g ated in ARTICLE 111. The Contractor shall proceed with the work to be performed under the provisions of this Contract on, or within ten (10) days following, er. the date of public acceptance of the Contractor's proposal by the Purchas Contractor shall not delay the start of the work to be performed under the Provisions of this Contract:except by written order from the Purchaser. Contractor shall complete said work by - February IN WITNESS WREREOF, the Parties hereto have executed this Contract as of day and year first written. CITY OF LUBBOCK ATTEST: BY: HEN Y , Ranette-Boyd, City Secretary b APPROVED AS TO CONTENT: .APPROVED AS TO FORM: DO D G, VANDIVER, ':Assistant ­Ctty-.Attorney PARTY OF THE SECOND PART (CONTRACTOR) ATTEST; _ BY. Signature of Officer �. ` Seer Title _ NOTE: This Contract must - be - signed - by _ the:President- � or- • Vice --President of -the Contractor's firm and attested by the Secretary of the*firm. If .the Contract is -to be signed by any person other than .the.Presid ent-or.Vice'-President, then a Board -Resolution authorizing said person to sign and bind the firm must be included -with each copy of the Contract. 230 KV AIR BREAK SWITCHES I. TYPE AND DESCRIPTION The switches to be furnished'under these specifications shall be of the outdoor type, 3 PST, manually group operated, rotating insulator, air , break switches, vertical break, and shall gave additional characteristics t as follows: .Voltage Rating (Volts) 230,000 - - Current Rating (Amps) 1,200 BIL (KV) 900 Switch Type. Disconnect Break Type Vertical Mounting Position Horizontal Insulator, cap and pin TR304 Insulator, color Sky Gray Operating Mechanism ..Manual 11. DESIGN All switches specified herein shall be -in accordance with the standards for power switching equipment of the National Electrical Manufacturers Associa- tion and shall be complete with NEMA Standard insulators: They shall be for operation at 230 KV and at an elevation 3,300 feet above sea level. -All ti current carrying parts of the switch blades shall be independent of any i` springs, hinges, or movable pin connections. All switches shall be equipped .3 with.seif-aligning contacts; high pressure contacts. Contacts shall have { suitable wiping action for self-cleaning. Each switch will be equipped with . standard NEMA pads.. Ill. OPERATING MECHANISM Each switch shall -be-furnished witb,a .group..operated remote manual operating -mechanism-for quick, simple and effective operation, and .shall be a worm drive crank or a lever. type. Each mechanism shall have a smooth, thoroughly controlled movement throughout the entire cycle, and shall be so arranged that the switch can be padlocked in either the open or closed position. Flexible* copper braid with suitable connector, for grounding each switch handle to' -12/0 copper ground shall be `included with each mechanism. The center of the operating handle or crank shall. be a distance of -3 ft. 6 inches above the.operating platform. IV. ACCESSORIES Each switch handle shall be furnished complete_ with the following accessories: (a). Air Switch Handle Interlock, -to be similar to A11is Chalmers Type ASMB - "solenoid" interlock -but modif ied- for the swi-tch...to._be-furnished, and 230 KV AIR BREAK SWITCHES (coni) IV. ACCESSORIES -Cont- for the appropriate switch rod size and travel arc, or.approved equal. The solenoid shall be designed for 125 VDC operation and the connection box shall be designed to, accommodate 1j" conduit; for control wiring. (b) Air Switch Handle Auxiliary Switch Assembly, similar to Allis Chalmers Type ASSY-STD auxiliary switch, modified for the switch to be furnished. A minimum of two (2) each electrically separated "A" contacts and "B" contacts will be required, complete with a terminal box to accommodate 11" conduit 'for control wiring, and designed to -mount on appropriate switch rod size, suitable substitute may be considered. V. MOUNTING Galvanized steel mounting bolts; washers, *etc.-, shalt be included herein; as required for mounting all groups -of -switches on their respective switch stands, or support structure members. Additional supports shall be required for each additional 15 feet in.length. of' the rod froin the switch .handle to the outboard bearing. V1. SWITCH OPFRATnR PlaTcnouc A switch operator grounding platform shall be furnished for each 230 KV switch. The platform shall be-as.indicated on the drawings. They shall be galvanized steel. Holes shall be provided in the frame of the platforms for attaching �ground terminals for -14/0 stranded co peer. VII. QUANTITY - Quantity... 1 115 KV AIR BREAM. SWITCHES I. TYPE AND DESCRIPTION The switches to be furnished under these specifications shall be of the outdoor type, 3 PST, groua operated rotating insulator, ai.r break switches, vertical break, and shall have the additional characteris- tics as follows: GROUP "A" GROUP "B" -GROUP "C" Voltage Rating (Volts) 115,000 115,000 115,000 Current Rating (Amps) 1,200 1,200 1,200 - BIL (KV) 550 550 550 Mounting Position Horizontal Horizontal Horizontal Insulator Type 286 286 286 Insulator Color Sky Gray Sky Gray Sky Gray Operating Mechanism Manual Motor Manual w/provision for motor Only copper or bronze switch blades will be accepted. An alternate quotation is requested for a switch with aluminum alloy blades. I1.. DESIGN REQUIREMENTS All switches specified herein shall be in -accordance with the -standards for power switching equipment of the National Electrical Manufacturers Association, and shall be complete with NEMA Standard insulators. All current carrying parts of the switch blades shall_ be independent of. any springs, hinges, or movable pin connectors. All switches shall be equipped with self -aligning, high pressure contacts. There shall be sufficient wiping action of the contacts to make them self-cleaning. Each switch shall be furnished with a group operated remote manual op- erating'mechanism, either the lever or geared type, for quick, simple and effective operation. Each mechanism shall have a smooth, thoroughly controlled movement throughout the entire cycle, and shall be so arranged ' that.the switch can be padlocked -in either the open or closed. position. A flexible copper braid with suitable connectors, for .grounding each switch handle to #1/0 copper aboveground structure ground -bus, shall be included with -each operating mechanism. The center of .the operating han- die or crank shall be a distance of 3 feet 6 inches above the -operator _ platform. The operating mechanism shall be mounted on the side of the switch stand or structure support. These air break switches will be located in a substation area approximately 3,300 feet above sea level, with an ambient temperature that -may vary between -300 to +1100 Fahren- heft. 11I. SWITCH OPERATOR PLATFORM . The switch operator platforms shall be supplied for each switch. The platforms shall be as indicated on the drawings. They shall be gal- -vanized.steel and have holes for grounding terminal clamps for #4/0 stranded copper. . lam" _l- 115 KV AIR BREAK SWITCHES-Con't- IV. MOTOR OPERATORS The motor operators to be furnished herein shall be ITE MO -10, Item 3. The switch shall have eight (8) auxiliary switch circuits available for use by the customer. The motor voltage and control voltage shall be 125 VDC. The motor operator shall open or close the switch•in less than ten (10) seconds. A separate fuse 125 V.A.C. heater shall be provided to prevent condensation. Provision shall be made to manually operate the switch. A control switch or pushbuttons shall be provided to operate the motor operator at the cabi.net. - V. QUANTITY Quantity Group "A'' ............... 23 Quantity Group "B" ..........:.... 0 Quantity Group "C" ............... 0 1• is i . i -2- SUBSTATION STEEL SPECIFICATIONS GENERAL REQUIREMENTS The steel structures and stands shall be of structural steel type and shall be furnished unassembled. The structures shall have spacings, clearances, and - mechanical details in accordance with the latest NEMA standards, with and as shown on the enclosed drawings. They shall be of hot dip galvanized steel, complete, and including the necessary bolts, washers, locknuts, anchor bolts, step bolts, and base plates as required, with each piece indexed to facilitate assembly and erection. 1. FABRICATION Before being laid out or worked in any manner, structural material shall be straight. If straightening is required, it shall be done by methods that will not injure the metal. Shearing and cutting.shall-be performed care- fully and finished neatly. Re-entrant cuts and copes on beams.or channels shall be filleted before cutting. Cuts made with an.acetelyne torch will not be permitted. All welding shall be performed in `accordance with the -latest edition of the "Code for Arc and .Gas Welding in Building Construction", as formulated by the American Welding Society. A shielded arc -welding pro- cess shall be used. All welds shall be made in such a manner that residual shrinkage stresses will be reduced to a minimum. No stress relieving .treat- ment will be required. All individual pieces shall be marked clearly with the correct designation shown on the shop drawings. Marking shall be done by stamping the marks into the metal before galvanizing, and shall be clearly legible -after -galvanizing... Stepbolts,- ladder bars, U -bolts and eye-bol-ts shall .be provided, wherever practical, on the line .dead end structures. Steps shall be spaced approximately fifteen (15) inches apart, with a max- imum allowable spacing of seventeen (17) inches. Holes for step bolts and ladder bars shall be in the inner gage of the leg angle. Diagonal members shall not be used for steps, and steps shall be spaced to avoid climbing interference with the outstanding leg -of the tower web members. 11. GALVANIZING After shop work has'been completed, all material shall be cleaned and be free from rust, loose scale, dirt, oil, grease, and other foreign substances.' After being cleaned, all materials shall be galvanized in accordance with ASTM Designation A-123 or the latest revision thereof. Where members are -of.such lengths that they -.cannot'.be dipped in one operation, great care shall be exercised to prevent warping. All plates and shapes which have been warped by the galvani.zi-ng process shah, be straightened by being re- ro�lled' or repressed: ..The material shall not be hammered or otherwise straightened in a manner that will injure the protective coating. All holes--in-the material--shal.l 'be -free. -from -excess •spelter-after-galvanizing. SUBSTATION STEEL SPECIFICATIONS -Con't- 111. BUS SUPPORT - L.A. - P.T. - CAP. POT. DEV. - STANDS Support stands shall be furnished for bus insulator supports as, shown in the drawings, or as necessary. Supports for the lightning arresters on each of the incoming lines, supports for the bus potential transformer, supports for the coupling capacitor devices on both of the lines. All supports shall have ground lugs for attaching 02/0 stranded copper ground lugs. The supports shall be designed to allow'easy access -to the mounting hardware below the top surface to facilitate the mounting of the equipment on the stand. IV. TOWERS AND STFUCTURES All switch towers "that are to support switches with future motor operators shall be designed to operate satisfactorily with either a manual or motor operator. The towers shall be designed to have adequate mechanical strength to meet -the requirements of each switch. Each switch will have lugs for grounding fl2/0 st. cu. 'The dead end strucutres shall be designed for' maximum unbalanced tension. Detailed requirements are as follows: - CONDUCTORS STATIC 115/69KV Pull Off Height Above Foundation in Feet 30 38 230 KV Pull Off Height Above Foundation in Feet :.:.. 50 60 115/69KV Maximum Puli-Off Tension in Lbs.......... •. - -.... 2500 1500 230KV Maximum Pull -Off Tension in Lbs. ....... 3000 1500 V. ANCHOR BOLTS All anchor bolts for all bus supports,•switch stands, L.A. .stands, P.T. stand; potential -capacitor devices; structures,' --poles and O.C.B.s will be supplied b, the successful bidder. VI: CLEARANCES In all cases the clearances shall meet or exceed the E--E.I. and N.E.M.A. standards or the I.E.E:E. recommendations. VII. STRUCTURE RIGIDITY All structures furnished for this substation shall be sufficiently rigid that no point on any strucutre will def lect.more than one inch W') from its norma] vertical position under the force of.a seventy -f ive.(75) mile per hour wind. VIII." DRAWINGS The supplier shall furnish complete substation structure -and arrangement drawings, foundation -and layout. drawings, and 'bills of .material. These drawings shall include,' but not. -.be- limited-to:the - following: complete foundation drawings,.showing "exact locations and dimensions of all foundations and .,anchor.bolts: The --spacing- and .'sizes -of "all -recommended =reinforcing -mater- ials -mater- ials-for-all -foundations. Plan view and elevation view of combined substation including, side -views, end views, and -sectional views -to• -show -dimensions and distances to be ,used for. -constructing the:,substion; overall dimensions of -2- SUBSTATION STEEL SPECIFICATIONS-Con't- principal columns and trusses; and for location of units of equipment to be installed in this substation. Grounding plan, including fence and gate ground- ing, equipment grounding, struc-tune grounding, including ground clamp'locations and ground rods. Electric circuit diagrams. Complete internal schematics and wiring diagrams for all material items furnished herein. Detailed steel erec- tion drawings shall show the AISI designation of each -member. Material de- scription list, and table of equipment and material, with proper item desig- nations to refer to the corresponding item shown in the .substation drawings. The supplier shall furnish other drawings as required for the orderly erection of the substation. - Two (2) complete sets of foundation drawings and anchor bolt drawings, sub- station structure drawings, arrangement drawings, layout drawings, and .biII of materials, as outlined above,' shall be furnished to L.P.& L. as soon as possible after award of contract for approval of the equipment covered by these specifications. Four (4) complete sets of steel erection drawings, installation drawings, wiring and installation details, etc., covering all items.of materials and equipment, shall be furnished as soon as possible after the approval, but not later than forty-five (45) days prior to the.time the structure is to be shipped. Any.special tools required for routine field servicing of equipment furnished herein shall be supplied at the time of shipment of such equipment, and shall be identified as to its usage. Following final delivery, the supplier shall furnish one.(1) set of repro �- ducibles of all substation drawings. -- The supplier.shall.furnish three (3) sets of instruction books --containing .detailed instructions for installation -operation; servicing,' maintenance, and connections of..all.equipment -furnished under -these specifications. These .shall include. a] 1. necessary diagrams, recommendations, and other data } to insure correct installation and operation of this equipment. i QUANTITIES Sufficient quantities of steel shal•1 be supplied to make acompleted instal - ]at -ion in -accordance with these specifications. Quantities -shall include, but not limited to the following: SUBSTATION STEEL SPECIFICATIONS -Con't- ►. McDONALD SUBSTATION ITEM KV QUANITY 1. Air Break Switch Stands 230 (1), One 2. Air Break Switch Stands 115 (17) Seventeen 3. Bus Support Stands 115 (79) Seventy Nine 4. Complete "A" Frames 230 (2) Two 5. Complete "A" Frames 115 (9) Nine 6. Potential Transformer Stands 230 (3) Three 7. Potential Transformer Stands 115 (3) Three 8. Wave Trap Stands (CCPD) 230 (1) One 9. Wave Trap Stands (CCPD) 115 (1) One VICKSBURG SUBSTATION . 1 :. Air .Break .Switch Stands - 115 ` -. (6) -Six . 2. Bus Support Stands 115. (1.5) Fifteen -3. Complete "A" Frames 115 (3) Three 4. Potential Transformer Stands_ 115' (3) Three 5.- -(CCPD) and Wave Trap Stands 115 (2) Two - - TOTAL;McDONALD"& VICKSBURG SUBSTATIONS 1. Air Break -Switch Stands 230 (1) One - 2. Air Break Switch Stands 11,5 (23) Twenty Three ! 3. .Bus Support Stands 115 (94) Ninety Four t 4. Complete "A" Frames 230 - .(2) Two #= . 5. Complete "A" Frames 115 (12). Twelve 6: Potential Transformer Stands 230- - (3) Three !: 7. Potential •Transformer Stands 115 (6) Six 8.' CCPD and Wave Trap Stands 230 (1) One 9. CCPD and Wave Trap Stands 115. (3). 'Three SUBSTATION PIPE BUS 1. GENERAL The tubing shall be seamless and in accordance with applicable specifica- tions of the American Society for Testing Materials.: All shall be commer- cially sound, straight, and uniform in thickness throughout. The tubing. shall be furnished in required lengths according to the enclosed drawings and equipment size. A suitable oxide paste in accordance with conductor manufacturer's recommendation shall be furnished for use on all connections of the tubing. All connectors and terminals shall be of an alloy having a conductivity not less than thetubing-with which they are to be used, and shall be "bolted type". All bolts and nuts for terminals and bus connectors shall be a non-magnetic alloy and shall be corrosion resistant. An end cover will be supplied for each end of the tubing. 11. REQUIREMENTS All.;pipe.bus shall be extra heavy "4 inch aluminum tubing; Specification No. 6063-T6, schedule 80. The supplier shall furnish -the necessary.SPS•alumi-. num pipe bus including .all connectors, terminals, 'bus-suppor•ts,.bus support clamps, 'fittings, couplings, end covers and expansion 'type sleeve connectors shall be --furnished when necessary-to'aIIow for expansion and -contraction of --bus pipe. The jumpers from A.B.S. to the 115 KV O.C.B.'s•-will be two 795 MCM ACSR conductors. The pipe bus -from the O.C.B.'s to the transformers - shall be.21 inch aluminum tubing, Specification No. 6063-T6, schedule 80. = l _ 115 KV INSULATORS 1. GENERAL All insulators furnished herein shall conform to the latest EEI, NEMA, and IEEE standards for insulators. The insulators shall have rating for phy- sical and electrical dimensions and characteristics for use at an elevation of 3,300 feet above sea level. The insulators shall be made of the highest grade, dense, homogenous, wet process porcelain, completely and uniformly vitrified throughout .to yield mechanical and electrical' strength and long life in service. The porcelain shall be free from warping, roughness, cracks, blisters, laminations, projecting points, foreign matter, and other defects, except those within the limits of standard accepted practice. Each insulator shall be marked with the initials or trademark of the manu- facturer. 'The marking shall be legible and durable. The insulators shall be furnished with a gray glaze. I1. BUS INSULATORS All bus insulators, as shown in the drawings, shall be included as a part. of. these specifications and shall be as follows: System Voltage (KV L -L)....... 1.15 Technical Reference No......... 286 BIL.. ............ 550 Type........... ..... Station Post .. ". All -bus' insulators shall be furnished. with all mounting bolts, bus supports, :and other, hardware,necessary_ for -..the installation of :the insulators. . SUSPENSION INSULATORS - All suspension insulators for:present-conductor dead-end assemblies as shown in the drawings,-.shall..be included as a part of -these -specifications. .All insulators shall conform to the following specifications: Insulator Per String (115 KV) ;:11 Type.. •.. .................5 - 3/4"xl0" Ball S Socket Reference No. .......... .Locke #1840 or approved equal Color.:... .... ..... ......Gray Glaze No Text GENERAL GROUNDING SPECIFICATIONS These specifications describe the materials to be supplied by the successful bidder, for all underground and above ground grounding at this substation. .All materials will be as specified or approved equal. - 1. 4/0 Soft Drawn Copper . _ . . . 2, 500 Feet 2. 2/0 Soft Drawn Copper . . . .10,000 Feet 3. 5/8 Inch x 8 Foot. Copperweld Ground Rods = _ Sp 4. 4/0 to 4/0 Connector Burndy Type YGL . . . ... 50 5. 4/0 -to 2/0 Connector Burndy.Type..YGHP ,_-,-1-50. 6. 2/0 to 2/0 Connector Burndy Type YGL . . . . . .-400. . _ , , _ . 7. 4/0 to 5/8 Ground Rod Connector�Burnd Type YGL Y .YP 50 - ` 8. .St_ructure.Groundi�g Clamps UTM X910-027'02. ;100 . ,All.bidders•shall include*i6.their proposal, dies wifh the 'capabilities -to `.complete.the installation of the above grounding materials. All dies shall ,= i; be applicable to the Burndy Y35, Y 5, or the 'Kearney 1495 Compression Tools., t - 230 KV STATION CLASS LIGHTNING ARRESTERS 1.0.0 GENERAL This specification covers the requirements for station class arresters to be applied on Lubbock Power & Light substations. The arresters shall be in accordance with the latest EEI and NEMA Standards for arresters. These lightning arresters shall be operating at an elevation of 3,300 feet above sea level. 115 KV/69 KV STATION CLASS LIGHTNING ARRESTERS 1.0 GENERAL This specification covers the requirements for station class lightning arresters to be -applied on Lubbock Power and Light substations. The lightning arresters shall be manufactured and tested in accordance with ANSI Standard C62.1 -1971, -or the latest revision thereof. These light-*- ning arresters shall be operated at an elevation of 3,300 feet above sea level. 2.0 RATINGS Arrester Rating (KV) 96/60 B.I.L. (KV) 550 - System Voltage (KV, L -L) 115/69 Class"Station Color` Sky Gray - Line Terminal 4 Hole Pad Ground Terminal #1/0 to X4/.0 St.Cu. Discharge Voltage *at 1.5 Ka* 197 KV r �._ Discharge Voltage *at 40 Ka 288 KV *Minimum discharge for discharge.current of 8X20 microsecond wave 'shape. 3..0 OPERATION i:- The 96.-KV..arrester -shall .be. composed • of: two(2) ;sections.- The arresters Will be initi;ally,operated as a-60 KV'arrester, and `at a_later date, ! coverted to..a .96 KV arrester.` Suitable terminals and jumpers shall be furnished to short out one section of the arrester while being operated . at 60 KV, and .to be removed while being -operated. at 96 KV. 4.0 QUANTITY Quantity. . 18 i 230 KV POTENTIAL TRANSFORMERS 1.0.0 GENERAL The potential transformer shall be single phase, 60 cycle, out -door type, oil filled, for use on a 23D KV solidly -grounded neutral system. Both secondary and primary polarities shall be adequately and properly indicated. The potential transformer bushings shall conform to the standards for apparatus bushings of the American Standards Association. - The color of the case and bushing shall be sky gray. The potential transformer shall be enclosed in a suitable weatherproof case. The case shall be equipped with lifting lugs capable of supporting the' en- tire weight of the transformer. The transformer case shall have a globe -type valve at the top and bottom of the case (for filter press connections) complete with plug. In addition, the bottom valve shall contain a separate oil sampling device, complete with dust cover. The transformer- case shall be equipped with a suitable grounding terminal. The secondary terminals shall be enclosed in a weatherproof compartment mounted at the base of the case. The compartment shall be arranged for connection to 11 inch conduit. The potential t-ransformers will be equipped with the following accessories, where applicable. A liquid level gauge mounted near the top of the high-voltage bushing and near the top of the case for oil filled transformers. A diagrammatic name plate mounted on the side of the case of tank. The supplier shall - furnish three (3) copies of instruction manuals and drawings of the type of potential transformer. 'These potential transformers shall be. operating at 3,300 feet above -sea level. 2.0.0 DETAILED REQUIREMENTS The --transformers ,shal,V.have- primary -windings -suitable, for• 1 ine-to-ground- connections on -a 230,000 volt solidlz- grounded neutral system. The wind- ;; ing_rat io shat:l -be 2000/1200c1.,.w1.th -the'primary.being 138, 000voIts,,and the secondary being 115;volts, with the secondary .tapped at 69 volts.- The transformer-.B.IL -shall-be 900 KV. The accuracy requirements will be , ?; ? as per ASA Standards. 3.-0.-0- OUANT I TY 115 KV POTENTIAL TRANSFORMERS 1.0.0 GENERAL The potential transformer shall be single phase, 60 cycle, out -door type, oil filled, for use on a 115 KV solidly -grounded neutral system. Both secondary and primary: polarit-ies shall be adequately and properly indi- cated. The potential transformer bushings shall conform to the standards for apparatus bushings of the American Standards Association. The color of the case and bushing shall be sky gray.. The potential transformer shall be enclosed in a suitable weatherproof case. The case shall be equipped with lifting lugs capable of supporting the entire weight of the -transformer: The transformer case shall have a globe -type valve -at the top and bottom of the case (for filter press connections) complete with plug-. In addition, the bottom valve shall contain a separate oil sampling device, complete with dust cover. The transformer case shall be equipped with a suitable grounding terminal. The secondary. terminals shall be enclosed in a weatherproof compartment mounted at the base of the case. 'The compartment -shall be -arranged for connection to 1} inch conduit. The potential transformers will be equipped with the following accessories, where applicable: A liquid level gauge mounted near the top of the high voltage bushing and near the top of the case for oil filled transformers; • A diagrammatic nameplate mounted on the side oV the case or tank.. The supplier shall furnish three- (3).copies of in- -struction manuals and'drawings of- the type of potential transformer. 2.0.0 DETAILED REQUIREMENTS The transformers shall have primary windings suitable for line -to -ground connections on a 115;000 volt solidly grounded-neutralsystem.:- The wind ing ratio shall be 1000/600:1, with the primary bei ng.69,000 volts, and the seconda ry -be i ng.] 15 -Vol ts,'with the secondary tapped -at 67.08 _volts. The transformer BIL shall be I' 550 "KV .The accuracy requirements -will be 1j as per ASA Standards. -. is 3.0.0. QUANTITY T� Quantity 6 PRODUCER 7-10-85 1-7 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, Greiner -Madison Insurance Agency, Inc. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. P.O. Box 30639 Amarillo, TX 79120 COMPANIES AFFORDING COVERAGE CRY A Transamerica Lloyds INSURED COMNERY B Transamerica Insurance Company of Texas Hallmark Builders of Lubbock, Inc. COMPANY 4009 Clovis Road P.O. Box 16209 LETTER C Mission National Insurance Company Lubbock, TX 79490-6209 LETTERNY Q Lumbermens Mutual .Casualty Company COMPANY LETTER E Royal Indemnity CITY OF LUBBOCK SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE DC- P.O. BOX 2000 LEFT, BAiT�MNR PPIIRILTION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO LE -T 04WAL.iIiBFFNt�T�OE� 10 DAYS WRITTEN NOTICE TO THE HAL4�RTIFICATE 38SE-N0QBLlC;�1gM OR L^!ll I: tf HO LDER NAMED TO THE Lubbock, T2XdS 79457 GF.ANY NiECOYfiAJ>v! tGENYSABJtERRESE6=IVES AUTHORIZEDPR NT 1 IS TO THAT POLICIES NOTWITHSTANDING CERTIFY ANY REQ IREMENT, OFINSURANCE TERM OR CONDITION OF (DOCUMENT INDICATED. BE ISSUED OR MAY PERTAIN, THE INSURANCE TIONS OF SUCH POLICIES. NY CONTRACT OR AFFORDED BY THE POLICIES DESCRIBED OTHER HEREIN IS SUBJECT WITEH RESPECT TO ALL THE TOOWHItHTHIS CERT( FICATE MAY TERMS, DCCLUSCERT AND CONDI- CO L TS TYPE OF INSURANCE POLICY NUMBER POLICI' EFfECfIVE POLICY E%PIRATION LIABILITY LIMITS IN THOUSANDS �� �� OpCEA H AGGREGATE GENERAL LIABILITY INJURY $ 500 $ 500 COMPRENENSNE FORM PREMISEsroPERATwNs DAMAGE '" $ 250 $ 250 UNDERGROUND NA2A E)(PLosiON NI PSE RD COLLA PRODIICTSICOMPLETED OPERATIONS emsBI INDED $ $ A INDEPENDENT CONTRACTORS MP19038621 1-1-85 1-1-86 BROAD FORM PROPERTY DAMAGE PERSONAL INJURY PERSONAL INJURY $ Incl AUTOMOBILE LIABILITY BMILYRM $ ANY AUTO X ALL OWNED AUTOS (PRN. PASS.) FBI I B X ALL OWNED AMOS (PRjvERF .) GLA19379038 1-1-85 1-1-86RM BODILY o $ X HIRED AUTOS X NON -OWNED AUTOS ROPE Y GARAGE LIABILITY $ PD COMBINED $ 500 EXCESS LIABILITY 1-1-86 C X UMBRELLA FORM OTHER THAN UMBRELLA FORM MN045827 1-29-85 BCOMBINED $ 3,000 $ 3 , 000 STATUTORY D WORKERS' COMPENSATION a pa rate Certificate of AND EMPLOYERS' LIABILITY Insurance to follow 2-1-85 2-1-86 $ (EACH ACCIDENT) (DISEASEPOLK,wuMln $ (DISEASE EACH EMPLOYEE] OTHER E All Risk Builders RQS360344 Risk 1-1-85 1-1-85 2,000 any building DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/SPECIAL ITEMS Station Service Buildings, McDonald and Vicksburg Substations CITY OF LUBBOCK SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE DC- P.O. BOX 2000 LEFT, BAiT�MNR PPIIRILTION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO LE -T 04WAL.iIiBFFNt�T�OE� 10 DAYS WRITTEN NOTICE TO THE HAL4�RTIFICATE 38SE-N0QBLlC;�1gM OR L^!ll I: tf HO LDER NAMED TO THE Lubbock, T2XdS 79457 GF.ANY NiECOYfiAJ>v! tGENYSABJtERRESE6=IVES AUTHORIZEDPR NT 1 STATUTORY PERFORMANCE BOND PURSUANT TO ARTICLE 5160 OF THE.REVISED CIVIL STATUTES OF TEXAS AS AMENDED BY ACTS OF THE 56TH LEGISLATURE REGULAR SESSION 1959 KNOW ALL MEN BY THESE PRESENTS, THAT HALLMARK BUILDERS OF LUBBOCK, INC. P.B. BOX 16209. LUBBOCK. TX 79490 (HEREINAFTER CALLED THE PRINCIPAL(S), AS PRINC.IPAL(S), AND HARTFORD CASUALTY INSURANCE COMPANY (HEREINAFTER CALLED THE SURETY(S), AS:SURETY(S), ARE HELD AND FIRMLY BOUND UNTO THE CITY OF LUBBOCK, P.B. 86X 2000. LUBBOCK, TX 79457 (HEREINAFTER CALLED THE OBLIGEE), IN THE AMOUNT'OF FORTY-FOUR THOUSAND NINt HUNDRED AND N4/104 ............... DOLLARS ($ 44*900'04 ) FOR THE PAYMENT WHEREOF, THE SAID PRINCIPAL AND SURETY BIND THEMSELVES, AND THEIR HEIRS, ADMINISTRATORS, EXECUTORS, SUCCESSORS AND ASSIGNS, JOINTLY AND SEVERALLY, FIRMLY BY THESE PRESENTS. WHEREAS, THE THE PRINCIPAL HAS ENTERED I TO A CERTAIN WRITT CONTRA TH OBLIGEE, DATED THE 28TH DAY OF UNE 1 TO &lwu T STATION SERVICE BUILDINGS FOR McDONALD AND VICKSBURG SUBSTATIONS WHICH CONTRACT IS HEREBY REFERRED TO AND MADE A PART HEREOF AS FULLY AND TO THE SAME EXTENT AS IF COPIED AT LENGTH HEREIN. NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION IS SUCH, THAT IF THE SAID PRINCIPAL SHALL FAITHFULLY PERFORM THE WORK IN ACCORDANCE WITH THE PLANS, SPECIFICATIONS. AND CONTRACT DOCUMENTS, THEN THIS OBLIGATION SHALL BE VOID: OTHERWISE TO REMAIN IN FULL FORCE AND EFFECT. PROVIDED, HOWEVER, THAT THIS,BOND IS EXECUTED PURSUANT TO THE PROVISIONS OF ARTICLE 5160 OF THE REVISED CIVIL STATUTES OF TEXAS AS AMENDED BY ACTS OF THE 56TH LEGISLATURE, REGULAR SESSION, 1959, AND ALL LIABILITIES ON THIS BOND SHALL BE DETERMINED IN ACCORDANCE WITH THE PROVISIONS OF SAID ARTICLE TO THE SAME EXTENT AS IF IT WERE COPIED AT LENGTH HEREIN. IN WITNESS WHEREOF,THE PAID PRINCIPAL(S) AIS S_URETY(S) HAVE SIG THIS INSTRUMENT THIS SS 19 DAY OF JU�.Y � SEED . HALL14ARK ILDERS BF LUBBOCK, ,INC. (PRINCI ) BY: (, (PRINCIPAL) HARTFORD CASUALTY INSURANCE ANV (C SURETY AMES B4VENZ ATTORNEY- -FA T HARTFORD CASUALTY INSURANCE COMPANY Executlw Office: Hartford, Connecticut POWER OF ATTORNEY Know all erten by these Presents, That the HARTFORD CASUALTY INSURANCE COMPANY, a corporation duly organized under the laws of the State of Now Jersey, and having its Executive Office in the City of Hartford. County of Hartford, State of Connecticut, does hereby make, constitute and appoint G. C. SAUNDERS, GUYON H. SAUNDERS, LEE NAPIER, ED A. FANCHER, DAN B. rLDffgING, WILLIAM L. HAMILTON, JR., JOHN W. MURRAY and JAMES J. BOVENZI of AMARILLO, TEXAS its true and lawful Attorney(s)-in-Fact, with full power and authority to each of said Attorney(s)-in-Fact, in their separate capacity if more than one is named above, to sign, execute and acknowledge any and all bonds and undertakings and other writings obligatory M the nature thereof on behalf of the company in its business of guaranteeing the fidelity of Persons holding places of public or private trust; guaranteeing the performance of eonVacts other than insurance poli_ cies; guaranteeing the performance of insurance contracts where surety bonds are accepted by states and municipal- ities, and executing or guaranteeing bonds and undertakings required or permitted in all actions or proceedings or by law allowed, and to bind the HARTFORD CASUALTY INSURANCE COMPANY thereby as fully and to the same extent as if such bonds and undertakings and other writings, obligatory in the nature thereof were signed by an Executive Officer of the HARTFORD CASUALTY INSURANCE COMPANY and sealed and attested by one other of such Officers, and hereby ratifies and confirms all that its said Attomey(s)in-Fact may do in pursuance hereof. This power of alto is granted under and by authority of the following Resolutions adopted by the ,Board of Directors of the HARTFORb CASUALTY INSURANCE COMPANY at a meeting duly called and hake on the 15th day of September, 1976. RESOLVED. that- the President or any Vice -President, acting with any Secretary or Assistant Secretary. shad have power and aPPoint, for Purposes aNy Of axecubng and attesting bonds and undertakings and other writings obligatory in lite nature thereof, one or morauthority to eResidera Vice -Presidents. Resident Assistant Secretaries and Atlomeys-in-Fact and at any time to remove any such Resident Vice -President. Resident Assis- taM Secretary. or Anomey-in-Fact, and revoke the power and authority grien to him. Attomeys•in-Fact ahed have power and authority. subject to the leans and limitations of the deliver on behalf of the Company and to attach the seal of the thereto Power of attomey issued to them, to sxewle and the nature thereof. and any such instrument executed Y any and all bonds and undertakings, and.otier writings obditatory in Executive Oticer end sealed and attested suchh homey in Fact shad be as binding upon " Company as d si by one other of such Olticers. fined by an RESOLVED, that Robert N. H. Seder. Assistant vice -President and Thomas F. Delaney, Assistant Vks-President, shsd each have, as long as he holds such office, the fame Powers as any vNwPreaidem Pursuant to the preceding Resolution. RESOLVED. thof at, whereas tie President or any Vice-president. acting with any Secretary or Assistant Secretary, has the Power and wthorily, to appoint oin obneaor wen Resident y. for prwpo� onlyof executingand attesting bonds and undertakings and other writings obligatory in the nature P d tesiren . Assistant Secretaries and Altomeystin-Fact: Now, therefore, the signatures of such Officers and the seal of the Company may be affixed to a such relating thereto by facsimk, and arty such Power of attomey or certificate bearing such facsimile fig�naturespa faesimr of a'b sey� shag por jo ie vajidfiyn� boding upon the Company and any such Dower nd executed and certified by factum le signatures and facsimile seal shad be valid and binding upon the Company m the future with respect to any bond or undertaking to which t is attached. RESOLVED. that. Robert N. H. Senor. Assistant Vice -President and Thomas F. Delaney, Ass stent Yoe PrasideM. Whey iadf. as brtp as he holds atreh office, affix his signature by fecsimb pursuant to and with the acme etect as that granted o vce-Proreside under the preceding w bon in Witness Whereof, the HARTFORD CASUALTY INSURANCE COMPANY has caused these presents to be signed by its Assistant Vice -President, and its corporate seal to be hereto affixed, duly attested by Its Secretary, this 15th day of September, 1976. Attest: HARTFORD CASUALTY INSURANCE COMPANY Mary Scharf. Secretary $� hA� /��y'�'`�' -7F '{Y Thomas F. Delaney STATE OF CONNECTICUT, Assistant Vice -President COUNTY OF HARTFORD. On this 15th day of September, A. D. 1976, before me personally came Thomas F. Delaney, to me known, who being by me duly swum; did depose and say: that he resides in the County of Hartford. State of Connecticut: that he is the Assistant Vice -President of the HARTFORD CASUALTY INSURANCE COMPANY, the corporation which executed the above instrument: that he knows the seal of the said corporation; that thyed lbed i and instrument is such corporate seal; that it was so affixed by order of the Board of Directors of said corporation and that he signed his name thereto by like order. STATE OF CONNECTICUT, I '+�• )} fa Gloria Mazotas, Notary Public MY COmmWsiOi1"'s march 3e-' rge3 COUNTY OF HARTFORD, CERTIFICATEExp 1, the undersigned. Assistant Secretary -of the HARTFORD CASUALTY INSURANCE COMPANY, a New,Jersey- corporation. DO HEREBY CERTIFY that the foregoing and attached POWER OF ATTORNEY remains in fug folt a Ind has not been revoked; and furthermore, that the Resolutions of the Board of Directors, set forth in the Power of Attorney, are now in force. Signed and sealed at the City of Hartford. Dated the day of ,U,v 985 _ Form 84SU-2 til hMead in u.sJ1. - �" .'.... ` • John E. Lukens Assistant Severely