HomeMy WebLinkAboutResolution - 2896A - Contract - Nix Electric Co - Sale Of Used Transformers - 08_11_1988Resolution #2896-A
August 11, 1988
Item 28
HW:js
occni iirrnni
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF LUBBOCK:
THAT the Mayor of the City of Lubbock BE and is hereby authorized and
directed to execute for and on behalf of the City of Lubbock a Contract by
and between the City of Lubbock and Nix Electric Co. for sale of used trans-
formers, attached herewith, which shall be spread upon the minutes of the
Council and as spread upon the minutes of this Council shall constitute and
be a part of this Resolution as if fully copied herein in detail.
Passed by the City Council this 11th day of August , 1988.
S. (� - j'&_ c -
S. C. McMI N, MAYOR
ATTEST
to Boyd, City Secretary
APPROVED- S TO CONTEN .
Wine Eads, Purchasing Manager
APPROVED AS TO FORM:
Harold Willard, Assistant City
Attorney
STATE OF TEXAS )
SALES CONTRACT
COUNTY OF LUBBOCK )
ARTICLE I.
1.01. This is a contract for sale of surplus property
between the City of Lubbock, Texas, and. Nix Electric Co.
who will be referred to as
Seller -and Buyer respectively.
1.02. This contract was drafted and executed at Lubbock,
Texas, and the laws of the State of Texas shall control and
govern this agreement.
1.03. The terms of this contract are intended by the
parties as a final expression of their agreement and also as a
complete and exclusive statement of all terms.
ARTICLE II. 4--
2.01. The surplus property that is the subject matter of
this contract is more fully described as:
Transformers for-Sale.as specified in Bid 9848 and specifications
attached hereto and made a part hereof.
2.02. The parties hereto intend the above description to
be only for purposes of identification of the goods and not a
part ofthe basis of this agreement.
2.03. The Seller has made no affirmation of fact or
promise relating to the property being sold that has become the
basis of this bargain. Further, the seller has made no
affirmation of fact of promise relating to the goods being sold
that has created or amounted to a warranty of any nature or kind
whatsoever, including express warranty, implied warranty of
merchantability, implied warranty or fitness or warranty against
infringement.
ARTICLE III.
3.01. The price for the surplus property that is the
subject matter of this contract is as follows: .
Complete Complete Defective Incomplete
Transformers: $4.05 Transformers: $1.29 Transformers: $0.96
ARTICLE IV.
4.01. It is understood that the Buyer is to take the
property being purchased as is at the location from which it was
sold. If disassembly is required, it shall be the responsibility
of the -Buyer to accomplish such disassembly.
4.02. The Buyer hereby agrees that during disassembly
and shipping of the surplus goods purchased, proof of insurance
in the following amounts must be furnished to the purchasing
officer of the City of Lubbock prior to disassembly or taking of
possession of such property:
A) Comprehensive General Liability Insurance: $300.00
Three hundred dollars and no.cents.
B) Comprehensive Automobile Liability Insurance: $300.00
Three hundred dollars and no cents.
4.03. The Buyer hereby agrees to hold the Seller
harmless from any claim or injury of any nature whatsoever that
should be brought against the Seller as a result of Buyer's
activities in connection with the purchase and removal of the
property that is the subject of this contract.
EXECUTED this 11th day of August , 1988, at
Lubbock, Texas.
Title
SELLER:
ame
Witness
NOTICE TO BIDDERS
BID # 9848
Sealed proposals addressed to Gene Eads, Purchasing Manager, City of Lubbock, Texas, will be —
received at the office of the Purchasing Manager, 1625 13th St., Room L-04, Lubbock, Texas, 79401, until
2:00 o'clock p.m. on the 29th day of July, 1988, or as changed by the issuance of formal addenda to all
planholders, to furnish all labor and materials and perform all work for the construction of the following
described project:
SALE OF USED TRANSFORMERS
After the expiration of the time and date above first written, said sealed proposals will be opened
by the Purchasing Manager at his office and publicly read aloud.
It is the sole responsibility of the bidder to insure that his bid is actually in the office of Gene
Eads, Purchasing Manager for the City of Lubbock, prior to the expiration of the date above first written.
The City Council will consider the bids on the 11th day of August, 1988, at Municipal Bldg.,
Lubbock; Texas, or as soon thereafter as may be reasonably convenient, subject to the right to reject any or
all bids and waive any formalities.
Bidders are required, whether or not a payment or performance bond is required, to submit a
cashier's or certified check issued by a bank satisfactory to the City of Lubbock, or a proposal bond from a
reliable surety company, payable without recourse to the order of the City of Lubbock in an amount not less
than 5% of the total amount of the bid submitted as a guarantee that bidder will enter into a contract and
execute all necessary bonds (if required) within 10 days after notice of award of the contract to him.
It shall be each bidders sole responsibility to inspect the site of the work and to inform himself
regarding all local conditions under which the work is to be done. It shall be understood and agreed that
all such factors have been thoroughly investigated and considered in the preparation of the bid submitted.
The plans, specifications, proposal forms and contract documents may be examined at the office of
the Purchasing Manager for the City of Lubbock, Texas.
Attention of each bidder is particularly called to the schedule of general prevailing rate of per
diem wages included in the contract documents on file in the office of the Purchasing Manager of the City of
Lubbock, which document is specifically referred to in this notice to bidders.
The City of Lubbock hereby notifies all bidders that in regard to any contract entered into pursuant
to this advertisement, minority and women business enterprises will be afforded equal opportunities to
submit bids in response to this invitation and will not be discriminated against on the grounds of race,
color, sex, or national origin in consideration for an award.
There will be a pre -bid conference on July 13, 1988 at 10:00 o'clock a.m. at Committee Room #103,
Municipal Building, 1625 13th Street.
.. .ors
rec Ad U%9-
NIX ELECTRIC CO., d.b.a.
Transf ormer Repair Service
July 27, 1988
Gene Eads, Purchasing Mgr
City of Lubbock
1625 13th Street
Lubbock, Tx 79401
Dear Sir,
We submit the following proposal on your Surplus Transformers,
per your Invitation #9848.
Intact, Non -leaking & in good working condition distri-
bution transformers. $ 4.05 per KVA
Intact distribution transformers that were removed from
service in a defective condition. $ 1.26 per KVA
'Alternate: Distribution transformers that are leaking
or have missing parts, that were removed from service
in a defective condition. $ .96 per KVA
Thank you.
Respectfully,
Mike Nix
Vice -President
MN/gd
720 S.E. Loop 289, Lubbock, Texas 79404 �EASA ° 110 Sentry Drive U., Mansfield, Texas 75063
806 - 745-4166 ���e...o�:� 817 - 477-3759 - Metro
BID PROPOSAL
BID FOR LUMP SUM CONTRACTS
PLACE Lubbock, Tx
DATE 7-29-88
PROJECT NO. 9848
Proposal of Nix Electric Company (hereinafter called Bidder)
To the Honorable Mayor and City Council City of Lubbock, Texas (hereinafter called owner)
Gentlemen:
purchase
The Bidder, in compliance with your invitation for bids for the il=tWJ i'.{K of a
various surplus distribution transformers.
Cashier's check as required by bid is attached.
having carefully examined the plans, specifications, instructions to bidders, notice to bidders and all
other related contract documents and the site of the proposed work, and being familiar with all of the
conditions surrounding the construction of the proposed project including the availability of materials and
labor, hereby proposes to furnish all labor, materials, and supplies; and to construct the project.in
accordance with the plans, specifications and contract documents, within the time set forth therein and at
the price stated below. The price to cover all expenses incurred in performing the work required under the
contract documents, of which this proposal is to be a part, is as follows:
BID: (see attached letter) (s
Amount shall be shown in both words and figures. In case of discrepancy,' the amount shown in words shall
govern.)
Bidder hereby agrees to commence the work on the above project on or before a date to be specified
In a written "Notice to Proceed" of the Owner and to fully complete the project within NINETY consecutive
calendar days thereafter as stipulated in the specifications and other contract documents. Bidder hereby
further agrees to pay to owner as liquidated damages the sum of $50.00 for each consecutive calendar day in
excess of the time set forth hereinabove for completion of this project, all as more fully set forth in the
general conditions of the contract documents.
Bidder understands and agrees that this bid proposal shall be completed and submitted in accordance
with instruction number 20 of the General Instructions to Bidders.
Bidder understands that the Owner reserves the right to reject any or all bids and to waive any
formality in the bidding.
The Bidder agrees that this bid shall be good and may not be withdrawn for a period of thirty (30)
calendar days after the scheduled closing time for receiving bids.
A1:111:11. CERTIFICATE OPINSURANCE
:;iSR.7�l'x�.'�su..3� -... .. <_'.•.._.. :; sA.. .. ....::....... <., .. ,..,...,;.,., ,, ,_..: x. 4.tw..�.idtlx ,.4.�:. ..v. ,..ew'.. ...h ... ,. A .... . \.,. .., _....._. ...,...�.._.-...._.._.
ISSUE DATE (MM/DDNY)
9 1 8$
PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS
NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND,
Dady Insurance Agency, Inc. EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW
P.O. Box 864
Georgetown, texas 78627 COMPANIES AFFORDING COVERAGE
i COMPANY A ,
LETTER
CODE SUB -CODE
COMPANY B
INSURED LETTER
Nix Electric Co. dba COMPANY
Transformer Repair Service
P.O. Box 10234 LETTER
Lubbock, Lubbock, Texas 79408
COMPANY E
LETTER
COVERAGES.« THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
i LTR
CO TYPE OF INSURANCE POLICY NUMBER i P_ _DATE (M D/YY) PDATE (MM/DD/YY)N: ALL LIMITS IN THOUSANDS
GENERAL LIABILITY t GENERAL AGGREGATE i t2 , 000.._�
A X _COMMERCIAL GENERAL LIABILITY PRODUCTS-COMPIOPS AGGREGATE 52 t 000 " -
^. CLAIMS MADE X�' OCCUR.r i PERSONAL R ADVERTISING INJURY $1 000
X. OWNER'S & CONTRACTOR'S PROT' TPP-30-113-5014 i 3-31-88 3-31-89 EACH OCCURRENCE is
' FIRE DAMAGE (Any one fire) ` S
MEDICAL EXPENSE (Any one person); ! 5
AUTOMOBILE LIABILITY SINGLE
COMBINED
i 1,000
ANY AUTO LIMIT_
A X ALL OWNED AUTOSBODILY
INJURY
Z6
X ' SCHEDULED AUTOS ' BUA 50-113-50-13 4-30-88 4-30-89 (Per -Peen)
X HIRED AUTOS j BODILY
INJURY � t
X ; MON OWNED AUTOS (Per accident) 5 1
' GARAGE LIABILITY PROPERTY
i
i0.1t
i DAMAGE
i EXCESS LIABILITY A EACH AGGREGATE
-- OCCURRENCE
j ?= $
a
_ ,OTHER THAN UMBRELUI
_ 1 i STATUTORY
A i wORKER'S COMPENSATION ?
Binder j 7-1-88 7-1-89 _ ACH ACCIDENT)
AND90....._ _ - -- —
!ISEASE—POLICY LIMIT)
EMPLOYERS' LIABILITY
S 1� (DISEASE —EACH EMPLOYE
OTHER _...__.._...._._._.
DESCRIPTION OF OPERATIONSILOCATiONS/MiCLES/RESTRICTIONS/SPECIAL ITEMS
r`CANCELLATION CERTIFICATE HOLDER.,; .�.�� .t�.- x�„ .,.�.� ,_:.�-�,._. _;.�.�.-��.r �.W�a� �-x,�h�._,1.:�,� •'� __.;:.,�.,,.ti�
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE
,City- of yLAbock EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO
MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE
#. LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR
LIABILITY O ANY KIND UPON THE CO NV, ITS AGENTS OR REPRESENTATIVES.
AUTHO REPREStENTArnE
. ., ..- I+.q>^»rv�
=s'L:^'s"'9" ,.: =fin-..n.a,e....:- ,,,.,.n„fi* an..•,...,.r.s»sMr_.-...-,.�•,»w-•._.-'�-:,t.-•s,+v--.,-..,.
ID (3/88i._ «" ' frk - �f,C+ACORD CORPORATION 1988
SPECIFICATION FOR SALE OF USED TRANSFORMERS
it 1. GENERAL
�= Lubbock Power and Light (LP&L) offers for sale used distribution
transformers as described on the attached list. This list may not
be accurate and may be incomplete. We believe the transformers in
question to be intact, non -leaking, and in good working condition.
LP&L also offers for sale numerous intact, distribution transformers
that have been removed from our system in a defective condition. A
list of defective transformers is not available. Determination of
available defective transformers must be made by site inspection.
2. REQUEST FOR QUOTATION
Each bidder (also termed "Buyer") shall submit a price for the good
transformers offered for sale and a separate price for the defective
transformers. Prices should be submitted on a per kVA basis.
The bidder quoting the highest price per kVA for the good
transformers will then be allowed to purchase any or all of the good
transformers at that price. Any good transformers remaining will
then be offered to the second highest bidder, then to the third
highest bidder and so on.
Selection of the defective transformers will be handled the same as
for the good units.
This bid will be considered active for one year from date of
closing. Any additional transformer's that become available for
i sale within that time period will be offered to the bidders based on
! the results of this bid.
I�
3. BIDDERS EXAMINATIONS AND INVESTIGATIONS
Inspections of the transformers may be made by contacting Don Cullon
at (806) 763-9381 Ext. 2561. The bidders should make a thorough
inspection of the transformers, as well as any adjacent areas, and
determine for their reference all conditions under which they will
be obligated to work.
The bidders should carefully and thoroughly examine all parts of
this specification and any data mentioned herein.
No plea of ignorance of conditions that may exist as a result of the
successful bidder's failure to make prudent examinations and
investigations will be accepted as an excuse for any failure or
omission on the part of the successful bidder to fulfill in every
detail all requirements of this specification, or will be accepted
as a basis for a claim for extra compensation, damages, or for an
extension of the time of completion.
LUBBOCK POWER AND LIGHT 1 06/16/88
SPECIFICATION FOR SALE OF USED TRANSFORMERS
4. EXCEPTIONS
It will be assumed .that all bidders will comply with this
specification. Any and all exceptions to this specification shall
be in writing and shall accompany the bid.
5. PCB CONTENT OF TRANSFORMERS
None of the transformers in question have been tested for PCB
content. All of the transformers were originally purchased as
mineral oil filled transformers. Any PCB contamination would be a
result of contamination obtained during the manufacturing process.
Our transformer oil vat used for servicing transformers has always
tested to be non -PCB.
6. DELIVERY
Buyer agrees to take delivery of the transformers to be purchased
from LP&L at 600 Municipal Hill Drive (LP&L Plant I I ) during
normal business hours within 30 days after being notified to begin
selection. The sales price shall be paid on or before the date of
such delivery.
7. TI TLE
At the time Buyer takes possession of the transformers at the above
location, title, risk of loss and all other incidents of ownership
shall be transferred from LP&L to the Buyer and vested in the Buyer.
8. LP&L WARRANTIES
LP&L warrants that title to the transformers is good and free from
any security interest or other lien or encumbrance and that, prior
to delivery to Buyer, LP&L.will exercise reasonable care in storage
of said transformers. However, the transformers are used and are
being sold AS IS and WITH ALL FAULTS, and, as to Buyer and third
parties, LP&L makes no warranties of merchantability or fitness for
a particular purpose. There are no LP&L warranties which extend
beyond the description on the face hereof.
9. BUYER WARRANTIES
Buyer warrants that it has inspected the transformers and it
understands that said transformers may contain polychlorinated
biphenyls (PCBs), a toxic substance as designated under the Toxic
Substances Control Act. Buyer further warrants that it is familiar
with the regulations of the U.S. Environmental Protection Agency
(EPA) restricting the manner in which PCB materials may be used,
handled, serviced, transported, distributed, and disposed of, as
well as all applicable State and local regulations. Buyer warrants
LUBBOCK POWER AND LIGHT 2 06/16/88
" SPECIFICATION FOR SALE OF USED TRANSFORMERS
:that it will comply with all applicable legal requirements during
its use and possession of the conveyed transformers. Buyer further
;'guarantees that such transformers, and its component parts and
`i ,;`fluids, if any, will be legally disposed of upon termination of use.
;.Buyer further warrants that it is under no legal or contractual
restrictions or prohibitions that would prevent Buyer from taking
'title to said transformers and agreed herein.
10.;INDEMNIFICATION
;'Buyer agrees to indemnify, save harmless and defend LP&L from and
against any and all liabilities, claims, penalities, forfeitures,
i suits, and costs and expenses incidental thereto (including costs of
defense, settlement and reasonable attorneys' fees) which LP&L may
incur, become responsible for or pay as a.result of death or bodily
injuries to any person, destruction or damage to any property,
contamination of or adverse effects on the environment, or violation
of any governmental laws, regulations, ordinances or orders, caused,
in whole or in part by (i) Buyer's breach of any term of the
Agreement, (ii) the act or omission of Buyer's agents or employees
while on LP&L premisses before, during or after delivery or (iii)
any act or omission of Buyer, its officers, agents, employees,
assignees, successors in interest, or any third party or parties,
arising out of or related to the transformers, or its component
parts or fluids, if any, conveyed by.the Agreement occuring after
Buyer takes delivery of said transformers.
11. QUESTIONS
Questions concerning the transformers or other aspect of the
techincal specification should be direct to:
Don Cullon, Associate Electrical Engineer
Lubbock Power and Light
P.O. Box 2000
Lubbock, Texas 79457
(806) 763-9381 Ext. 2561
Questions related to or concerning the bid process should be
directed to:
Gene Eads, Purchasing
City of Lubbock
1625 13th Street
Lubbock, Texas 79401
(806) 762-6411 Ext.
Manager
2165
;�-� LUBBOCK POWER AND LIGHT 3 06/16/88
LUBBOCK POWER AND LIGHT
5
;
MANUFACTURER
KVA
P. VOLTAGE
S. VOLTAGE
SERIAL #
CO. #
1
ALLIS
CHALMERS
5
120/240
1964402
1268
�� 3
ALLIS
CHALMERS
5
120/240
1964374
1264
;;.; 4
ALLIS
CHALMERS
5
2400/4160
120/240
1766532
966
! 5
ALLIS
CHALMERS
5
2400/4160
120/240
1964393
1267
ALLIS
CHALMERS
5
2400/4160
120/240
1964381
1265
!.'7
ALLIS
CHALMERS
5
2400/4160
120/240
1728578
932
8
ALLIS
CHALMERS -
5
2400/4160
120/240
2337445
2322
...h.9
ALLIS
CHALMERS
5
2400/4160
120/240
1728567
937
j•�10
ALLIS
CHALMERS
5
2400/4160
120/240
1728568
931
:;'11
ALLIS
CHALMERS
5
2400/4160
120/240
1766495
957
._ 12
ALLIS
CHALMERS
5
2400/4160
120/240
1964319
1261
,;.13
ALLIS
CHALMERS
5
2400/4160
120/240
1964383
126
1.14
GENERAL
ELECTRIC
5
2400/4160
120/240
B183619
2863
`15
GENERAL
ELECTRIC
5
2400/4160
120/240
5402359
583
°'16
GENERAL
ELECTRIC
5
2400/4160
120/240
B175832A
2861
;.�:17
GENERAL
ELECTRIC
5
2400/4160
120/240
9165935A
2905
18
GENERAL
ELECTRIC
5
2400/4160
120/240
9292741
1991
'19
LINE
MATERIAL
5
110/220
97486
743
.'20
LINE
MATERIAL
5
110/220
97506
794
21
LINE
MATERIAL
5
2400/4160
120/240
99579
740
LINE
MATERIAL
5
2400/4160
120/240
128028
763
;:'23
LINE
MATERIAL
5
2400/4160
120/240
128065
754
:•'--24
LINE
MATERIAL
5
2400/4160
120/240
67765
631
..1-'25
'j26
LINE
MATERIAL
5
2400/4160
120/240
659651
1236
LINE
MATERIAL
5
2400/4160
120/240
133868
768
.,427
LINE
MATERIAL
5
2400/4160
120/240
659552
1234
128
LINE
MATERIAL
5
2400/4160
120/240
134485
797
!1129
MCGRAW
EDISON
5
2400/4160
120/240
1213547
2713
'30
ALLIS
CHALMERS
7.5
2400/4160
120/240
1760301
946
31
ALLIS
CHALMERS
7.5
2400/4160
120/240
1686579
947
32
ALLIS
CHALMERS
7.5
4160Y/2400
120/240
2074968
1458
1!'33
GENERAL
ELECTRIC
7.5
2400/4160
120/240
4989526
505
J '34
LINE
MATERIAL
7.5
110/220
129968
773
,' 35
LINE
MATERIAL
7.5
2400/4160
120/240
627391
1196
'36
LINE
MATERIAL
7.5
2400/4160
120/240
625805
1177
1137
LINE
MATERIAL
7.5
2400/4160Y
120/240
539498
1117
?.1:38
ALLIS
CHALMERS
10
2400
240
1829913
1035
ALLIS
CHALMERS
10
2400/4160
120/240
1766425
956
1=40
ALLIS
CHALMERS
10
2400/4160
120/240
1984934
1213
41
ALLIS
CHALMERS
10
2400/4160
120/240
2076681
1424
42
ALLIS
CHALMERS
10
2400/4160
120/240
2027127
1413
�43
ALLIS
CHALMERS
10
2400/4160
120/240
2533597
3393
44
ALLIS
CHALMERS
10
2400/4160
120/240
2087815
1473
45
ALLIS
CHALMERS
10
2400/4160
120/240
2373343
2622
''46
ALLIS
CHALMERS
10
2400/4160
120/240
2506488
3236
; 47
ALLIS
CHALMERS
10
2400/4160
120/240
2506544
3248
48
ALLIS
CHALMERS
10
2400/4160
120/240
.2112060
1542
49
ALLIS
CHALMERS
10
2400/4160
120/240
1984936
1314
50
ALLIS
CHALMERS
10
2400/4160
120/240
2483447
3102
51
ALLIS
CHALMERS
10
2400/4160
120/240
2341469
2290
52
ALLIS
CHALMERS
10
2400/4160
120/240
2533596
3392
53
ALLIS
CHALMERS
10
2400/4160
120/240
2087758
1468
;54
CENTRAL
10
4160/7200
120/240
4343-12
4208
'55
GENERAL
ELECTRIC
10
2400/4160
240/480
7663023
1082
56
GENERAL
ELECTRIC
10
2400/4160
120/240
B307529A
2654
"GOOD TRANSFORMERS TO SELL PAGE 1 06/20/88
LUBBOCK POWER AND LIGHT
MANUFACTURER KVA P. VOLTAGE S. VOLTAGE SERIAL # CO. #
57
GENERAL ELECTRIC
10
2400/4160
120/240
B378256
2842
58
GENERAL ELECTRIC
10
2400/4160
240/480
7663016
1081
59
GENERAL ELECTRIC
10
2400/4160
120/240
B256053
2166
60
GENERAL ELECTRIC
10
2400/4160
120/240
B256050
2164
61
GENERAL ELECTRIC
10
2400/4160
120/240
B-380616
2843
62
GENERAL ELECTRIC
10
2400/4160
120/240
B-273710
2240
63
GENERAL ELECTRIC
10
2400/4160
120/240
B253508
220-1
64
GENERAL ELECTRIC-
10
2400/4160
120/240
8956098
1878
65
LINE MATERIAL
10
120/240
807430
1391
66
LINE MATERIAL
10
120/240
660190
1304
67
LINE MATERIAL
10
110/220
173850
830
.68
LINE MATERIAL
10
220
52761
621
69
LINE MATERIAL
10
2400/4160
120/240
843463
1421
70
LINE MATERIAL
10
2400/4160
120/240
1097172
2060
71
LINE MATERIAL
10
2400/4160
120/240
806882
1388
72
LINE MATERIAL
10
2400/4160
120/240
1182797
2677
73
LINE MATERIAL
10
2400/4160
120/240
1110234
2139
74
LINE MATERIAL
10
2400/4160
120/240
1092827
1937
75
LINE MATERIAL
10
2400/4160
120/240
1114706
2072
,76
LINE MATERIAL
10
2400/4160
120/240
1166438
2541
77
LINE MATERIAL
10
2400/4160
120/240
98225
739
78
LINE MATERIAL
10
2400/4160
120/240
1097173
2061
79
LINE MATERIAL
10
2400/4160
120/240
1116566
2075
80
LINE MATERIAL
10
2400/4160
120/240
1166476
2547
81
LINE MATERIAL
10
2400/4160
120/240
627450
1189
82
LINE MATERIAL
10
2400/4160
120/240
1092793
2126
83
LINE MATERIAL
10
2400/4160
120/240
1084832
1925
84
LINE MATERIAL
10
2400/4160
120/240
850820
1434
85
MALONEY
10
2400/4160
120/240
880187
1863
86
MCGRAW EDISON
10
2400/4160
120/240
880177
1857
87
MCGRAW EDISON
10
2400/4160
240/480
853571
1419
,88.MCGRAW
EDISON
10
2400/4160
120/240
880175
1855
89
MCGRAW EDISON
10
2400/4160
120/240
1161078
2191
90
MCGRAW EDISON
10
2400/4160
120/240
880188
1861
91
MOLONEY
10
2400/4160
120/240
118915
2512
92
MOLONEY
10
2400/4160
120/240
1189517
2513
93
WESTINGHOUSE
10
2400
120/240
5675546
2373
94
WESTINGHOUSE
10
2400/4160
120/240
5130615
1749
95
ALLIS CHALMERS
15
120/240
2076835
1415
96
ALLIS CHALMERS
15
120/240
1932409
1287
97
ALLIS CHALMERS
15
440
1765329
939
98
ALLIS CHALMERS
15
2400
120/240
2118750
1527
99
ALLIS CHALMERS
15
2400
120/240
2366676
2331
100
ALLIS CHALMERS
15
2400/4160
120/240
1765325
942
101
ALLIS CHALMERS
15
2400/4160
120/240
1947252
1281
102
ALLIS CHALMERS
15
2400/4160
120/240
2365987
2261
103
ALLIS CHALMERS
15
2400/4160
120/240
2437560
2988
104
ALLIS CHALMERS
15
2400/4160
120/240
1693279
862
105
ALLIS CHALMERS
15
2400/4160
120/240
2026283
1401
106
ALLIS CHALMERS
15
2400/4160
120/240
2437344
3030
107
ALLIS CHALMERS
15
2400/4160
120/240
2147089
1743
108
ALLIS CHALMERS
15
2400/4160
120/240
2118699
1522
109
ALLIS CHALMERS
15
2400/4160
120/240
2076867
1417
110
ALLIS CHALMERS
15
2400/4160
120/240
1755185
949
111
ALLIS CHALMERS
15
2400/4160
120/240
1869750
1063
112
ALLIS CHALMERS
15
2400/4160
240/480
2021594
1397
rnnf) TpenmCnpNcpC Tn cci i per n�I7f1IRR
R /
LUBBOCK POWER
AND LIGHT
t
MANUFACTURER
KVA
P. VOLTAGE
S. VOLTAGE
SERIAL #
CO. #
:113
ALLIS CHALMERS
15
2400/4160
120/240
1900939
1104
11.14
ALLIS CHALMERS
15
2400/4160
120/240
2437549
2987
,115
ALLIS CHALMERS
15
2400/4160Y
120/240
1873190
1074
416
CENTRAL
15
2400/4160
120/240
4325-14
4242
117
CENTRAL
15
2400/4160
120/240
4502-2
4423
118
CENTRAL
15
2400/4160
120/240
2660-16
3753
4,19
CENTRAL
15
2400/4160
120/240
3594-15
1455
:120
CENTRAL
15
2400/4160
120/240
3067-12
3959
j121
CENTRAL
15
2400/4160
120/240
2640-17
3674
,122
CENTRAL
15
2400/4160
120/240
2660-6
3695
123
CENTRAL
15
2400/4160
120/240
4326-12
4234
=";124
CENTRAL
15
2400/4160
120/240
4504-7
4426
1?125
CENTRAL
15
2400/4160
120/240
2660-7
3696
1126
CENTRAL
15
2400/4160
120/240
4194-9
4268
1127
CENTRAL
15
2400/4160
120/240
4326-3
4237
1128
CENTRAL
15
2400/4160
120/240
2640-18
3675
1129
CENTRAL
15
2400/4160
120/240
2660-14
3751
J 30
CENTRAL
15
2400/4160
120/240
2660-22
3758
131
CENTRAL
15
2400/4160Y
120/240
4432-10
4430
132
CENTRAL
15
2400/4160Y
120/240
4432-8
4433
'133
CTC
15
2400/4160
120/240
2640-4
3666
134
CTC
15
2400/4160
120/240
2660-10
3698
:135
CTC
15
2400/4160Y
120/240
3067-7
3957
136
CTC
15
4160/7200
120/240
4344-2
4204
137
GENERAL ELECTRIC
15
220
3581083
132
138
GENERAL ELECTRIC
15
2400
120/240
9246118
1726
139
GENERAL ELECTRIC
15
2400
120/240
9245969
1718
140
GENERAL ELECTRIC
15
2400/4160
120/240
E709201-61K
?
141
GENERAL ELECTRIC
15
2400/4160
120/240
B-387044
2859
142
GENERAL ELECTRIC
15
2400/4160
120/240
B377778A
2855
143
GENERAL ELECTRIC
15
2400/4160
120/240
E581413-60K
6468
144
GENERAL ELECTRIC
15
2400/4160
120/240
5313795
3497
145
GENERAL ELECTRIC
15
2400/4160
120/240
8254050
2087
1146
GENERAL ELECTRIC
15
2400/4160
120/240
B252173
2109
147
GENERAL ELECTRIC
15
2400/4160
120/240
E709199-61K
?
148
GENERAL ELECTRIC
15
2400/4160
120/240
E871108-62Y
6253
149
GENERAL ELECTRIC
15
2400/4160
120/240
8252065
2106
150
GENERAL ELECTRIC
15
2400/4160Y
120/240
E870081-62Y
6252
151
GENERAL ELECTRIC
15
7200
120/240
6714157
56X
r152
LINE MATERIAL
15
120/240
666465
1347
'153
LINE MATERIAL
15
2400/4160
120/240
1154025
2236
1154
LINE MATERIAL
15
2400/4160
120/240
1203488
2874
.155
LINE MATERIAL
15
2400/4160
120/240
1167217
2291
156
LINE MATERIAL
15
2400/4160
120/240
647688
325
157
LINE MATERIAL
15
2400/4160
120/240
62030
614
'158
LINE MATERIAL
15
2400/4160
120/240
666460
1346
159
LINE MATERIAL
15
2400/4160
120/240
1167225
2292
160
LINE MATERIAL
15
2400/4160
120/240
1211824
2899
161
LINE MATERIAL
15
2400/4160
120/240
676577
1353
.162
LINE MATERIAL
15
2400/4160
120/240
1167327
2295
163
MALONEY
15
2400/4160
120/240
1224715
2823
164
MALONEY
15
2400/4160
120/240
1210577
2660
165
MCGRAW EDISON
15
2400/4160
120/240
1345842
360
166
MCGRAW EDISON
15
2400/4160
120/240
1371901
421
167
MCGRAW EDISON
15
2400/4160
120/240
1224004
2816
�168
MCGRAW EDISON
15
2400/4160
120/240
1350591
367
f'nnn TD'AKlCCnDMCCC Tf) CCI I CACC O n4 /7n/Q0
LUBBOCK POWER AND LIGHT
MANUFACTURER KVA P. VOLTAGE S. VOLTAGE SERIAL # CO. #
169
MCGRAW EDISON
15
2400/4160
120/240
1371897
402
170
MCGRAW EDISON
15
2400/4160
120/240
1272601
3092
171
MCGRAW EDISON
15
2400/4160
120/240
1350593
373
172
MCGRAW EDISON
15
2400/4160
120/240
1224719
2827
173
MCGRAW EDISON
15
2400/4160
120/240
1210573
2656
174
MCGRAW EDISON
15
2400/4160
120/240
1311218
348
175
MCGRAW EDISON
15
2400/4160
120/240
1211372
2695
176
MCGRAW EDISON -
15
2400/4160
120/240
1371892
390
177
MCGRAW EDISON
15
2400/4160Y
120/240
1371899
410
178
WAGNER
15
2400/4160
120/240
L901228
2352
179
WESTINGHOUSE
15
2400/4160
120/240
6421444
3484
-=180
WESTINGHOUSE
15
2400/4160
120/240
4577611
3596
181
WESTINGHOUSE
15
2400/4160
120/240
5590329
2118
182
WESTINGHOUSE
15
2400/4160
120/240
6512088
251
183
WESTINGHOUSE
15
2400/4160Y
120/240
60AH695
5768
184
WESTINGHOUSE
15
2400/4160Y
120/240
60AK2142
6022
185
WESTINGHOUSE
15
7200/12470Y
240/480
70AJ5105
9787
186
ALLIS CHALMERS
25
120/240
1977611
1295
187
ALLIS CHALMERS
25
240/480
1957916
1232
188
ALLIS CHALMERS
25
2400
120/240
2173309
1714
189
ALLIS CHALMERS
25
2400
120/240
2149275
1588
190
ALLIS CHALMERS
25
2400
120/240
2118592
1670
191
ALLIS CHALMERS
25
2400/4160
120/240
1977763
1303
192
ALLIS CHALMERS
25
2400/4160
120/240
2248983
1994
193
ALLIS CHALMERS
25
2400/4160
240/480
1978280
1326
194
ALLIS CHALMERS
25
2400/4160
120/240
2149234
1585
195
ALLIS CHALMERS
25
2400/4160
120/240
2166856
3598
196
ALLIS CHALMERS
25
2400/4160
120/240
2149112
1577
197
ALLIS CHALMERS
25
2400/4160
240/480
1955135
1231
198
CENTRAL
25
2400/4160Y
120/240
4434-1
4307
199
CTC
25
2400/4160
120/240
2558-9
3654
200
CTC
25
2400/4160
240/480
7230-9
6014
201
CTC
25
2400/4160
120/240
2641-10
3656
202
CTC
25
2400/4160Y
120/240
9820-17
6767
203
CTC
25
4160/7200
120/240
4343-1
4203
204
GENERAL ELECTRIC
25
2400/4160
120/240
B-251299
2099
205
GENERAL ELECTRIC
25
2400/4160
120/240
F889098-64Y
7249
206
GENERAL ELECTRIC
25
2400/4160
240/480
7296361
1119
207
GENERAL ELECTRIC
25
2400/4160Y
120/240
F866293-64Y
714'1
208
GENERAL ELECTRIC
25
2400/4160Y
120/240
E903686-62Y
6659
209
GENERAL ELECTRIC
25
2400/4160Y
240/480
F881725-64Y
7246
210
GENERAL ELECTRIC
25
2400/4160Y
120/240
D963390-59Y
5406
211
LINE MATERIAL
25
120/240
647515
1230
212
LINE MATERIAL
25
2400/4160Y
240/480
602301
1169
213
MALONEY
25
2400/4160
120/240
1209160
2689
214
MALONEY
25
2400/4160
120/240
1214236
2792
215
WAGNER
25
2400
480
324164
900
216
WAGNER
25
7200/4160
120/240
J9E1538
3024
217
WAGNER
25
7200/4160
120/240
J9E1539
2922
218
WESTINGHOUSE
25
2400/4160
240/480
63AH2565
6972
219
WESTINGHOUSE
25
2400/4160Y
120/240
63AL4469
6995
220
WESTINGHOUSE
25
2400/4160Y
120/240
64AG4069
7222
221
WESTINGHOUSE
25
2400/4160Y
120/240
63AK7932
6904
222
WESTINGHOUSE
25
2400/4160Y
120/240
92AH1139
6848
223
WESTINGHOUSE
25
2400/4160Y
120/240
64AG6839
7167
224
WESTINGHOUSE
25
2400/4160Y
240/480
64AS268
6970
r_nnn TDAKlCC-nDMCDC Tr) CCI I
'
LUBBOCK POWER
AND LIGHT
MANUFACTURER
KVA
P. VOLTAGE
S. VOLTAGE
SERIAL #
CO. #
225
WESTINGHOUSE
25
2400/4160Y
120/240
63AL2688
7069
226
WESTINGHOUSE
25
2400/4160Y
120/240
57-G14-253
4596
227
WESTINGHOUSE
25
2400/4160Y
120/240
64AF6476
7224
`228
WESTINGHOUSE
25
4160/7200
240/480
4257020
1378
229
WESTINGHOUSE
25
4160/7200
240/480
4257019
1377
230
WESTINGHOUSE
25
4160/7200
240/480
4257017
1375
231
WESTINGHOUSE
25
4160/7200Y
120/240
3126557
4895
232
ALLIS CHALMERS
37.5
2400/4160
120/240
1727951
1828
233
ALLIS CHALMERS
37.5
2400/4160
120/240
1822088
1841
234
ALLIS CHALMERS
37.5
2400/4160
120/240
1727949
1827
235
LINE MATERIAL
37.5
220
133012
785
-236
LINE MATERIAL
37.5
2400/4160
120/240
71350
661
237
PENN
37.5
2400
120/240
16844-5
1982
238
WAGNER
37.5
2400/4160
120/240
J9E1589
2926
.239
WAGNER
37.5
2400/4160
120/240
J9E1585
2924
240
WAGNER
37.5
2400/4160
120/240
J9E1584
2923
241
ALLIS CHALMERS
50
2400
120/240
2113555
1607
242
ALLIS CHALMERS
50
2400/4160
120/240
1977176
1289
.243
ALLIS CHALMERS
50
2400/4160
120/240
2447947
3051
244
ALLIS CHALMERS
50
2400/4160
120/240
1977200
1291
245
CTC
50
2400/4160Y
120/240
9322-1-3
6356
.246
CTC
50
2400/4160Y
240/480
9705-6
6565
247
CTC
50
2400/4160Y
240/480
9705-5
6564
248
CTC
50
2400/4160Y
120/240
7642-13
5906
249
GENERAL ELECTRIC
50
220
5029787
3
250
GENERAL ELECTRIC
50
2400/4160
120/240
B-368305
2733
'251
GENERAL ELECTRIC
50
2400/4160Y
120/240
D625575-57Y
4729
'252
LINE MATERIAL
50
220
92166
778
253
LINE MATERIAL
50
2400/4160Y
311698
1043
254
MALONEY
50
2400/4160
120/240
1215551
2735
255
MOLONEY
50
2400/4160
120/240
891586
1909
256
RTE
50
2400/4160Y
120/240
4309042
7281
257
WESTINGHOUSE
50
2400/4160
120/240
3948257
3579
258
WESTINGHOUSE
50
2400/4160
120/240
6074145
_ 615
259
WESTINGHOUSE
50
2400/4160
120/240
5975314
2911
260
WESTINGHOUSE
50
2400/4160Y
120/240
60AL5898
5767
261
WESTINGHOUSE
50
2400/4160Y
120/240
61AG4087
6105
262
WESTINGHOUSE
50
2400/4160Y
120/240
59AJ1858
5420
263
WESTINGHOUSE
50
2400/4160Y
120/240
61AA5184
6104
264
ALLIS CHALMERS
75
2400/4160
120/240
2445229
3015
265
ALLIS CHALMERS
75
2400/4160
120/240
2445149
3009
266
ALLIS CHALMERS
75
2400/4160
120/240
2445220
3012
.267
ALLIS CHALMERS
75
2400/4160
120/240
2445208
3011
268
GENERAL ELECTRIC
75
2400/4160
120/240
8634597
1673
269
GENERAL ELECTRIC
75
2400/4160
120/240
8631302
1674
270
GENERAL ELECTRIC
75
2400/4160Y
120/240
E712785-61K
6308
271
LINE MATERIAL
75
2400/4160
240/480
131709
914
272
LINE MATERIAL
75
2400/4160
240/480
1401315
310
273
LINE MATERIAL
75
2400/4160
240/480
131710
915
274
LINE MATERIAL
75
2400/4160
120/240
799081
1383
275
LINE MATERIAL
75
2400/4160
240/480
131708
913
276
LINE MATERIAL
75
2400/4160
120/240
1186379
2734
277
PENN
75
2400/4160Y
120/240
6-15595-1-2
6741
278
UPTEGRAPH
75
2400/4160
120/240
61362
3443
279
UPTEGRAPH
75
2400/4160
120/240
61363
3444
280
UPTEGRAPH
75
2400/4160
120/240
61528
3466
nnn TPGNgPnPMPPq Tn qri I Paf:F S nA /')n /AA
LUBBOCK POWER AND LIGHT
MANUFACTURER
KVA
P. VOLTAGE
S. VOLTAGE
SERIAL #
CO. #
281
WAGNER
75
2400/4160Y
120/240
5R48009
5801
282
ALLIS CHALMERS
100
2400/4160
120/240
2491190
3507
283
CTC
100
2400/4160Y
120/240
9761-3
6476
284
CTC:
100
2400/4160Y
120/240
9730-6 -
6475
285
GENERAL ELECTRIC
100
2400/4160
120/240
8671519
2079
286
GENERAL ELECTRIC
100
2400/4160
120/240
9647775
2080
287
GENERAL ELECTRIC-
100
2400/4160Y
120/240
E887543-62Y
6307
288
LINE MATERIAL100
2400/4160
240/480
1337046
294
289
MCGRAW EDISON
100
2400/4160
240/480
1755074
3372
290
MCGRAW EDISON
100
2400/4160
240/480
1755077
3374
291
MCGRAW EDISON
100
2400/4160
120/240
1750566
1897
292
MCGRAW EDISON
100
2400/4160
.120/240
1750783
1.904
293
MCGRAW EDISON
100
2400/4160
240/480
1755075
3373
294
MOLONEY
100
2400/4160
120/240
1750782
1903
295
WAGNER
100
2400/4160
120/240
M901261
2620
296
WAGNER
100
2400/4160Y
120/240
5N58445
5263
297
ALLIS CHALMERS
167
2400/4160
240/480
2492863
13627
298
ALLIS CHALMERS
167
2400/4160
240/480
2621641
13844
299
ALLIS CHALMERS
167
2400/4160
240/480
2621639
13843
300
ALLIS CHALMERS
167
2400/4160
240/480
2492855
13626
301
ALLIS CHALMERS
167
2400/4160
240/480
2492846
13625
302
ALLIS CHALMERS
167
2400/4160Y
120/240
3103008
4855
303
CENTRAL
167
2400/4160
120/240
4767-3
4460
304
CENTRAL
167
2400/4160
120/240
4767-2
4459
305
CENTRAL
167
2400/4160
120/240
4767-1
4458
306
CENTRAL
167
2400/4160
120/240
4100-3
4246
307
CENTRAL
167
2400/4160
120/240
7171-2
5414
308
CTC
167
2400/4160Y
120/240
8118-3
5895
309
CTC
167
2400/4160Y
120/240
9878-1
6567
310
CTC
167
2400/4160Y
120/240
10572-1
6805
311
MCGRAW EDISON
167
2400/4160
120/240
1751544
2264
312
PENN
167
2400/4160
120/240
17178-1
1946
313
PENN
167
2400/4160
120/240
17178-2
1947
314
PENN
167
2400/4160
120/240
17178-3
1948
315
WAGNER
167
2400/4160
120/240
5N1025
4905
316
GENERAL ELECTRIC
250
2400/4160
120/240
F489189-64P
7272
317
GENERAL ELECTRIC
250
2400/4160
120/240
F489187-64P
7271
318
GENERAL ELECTRIC
250
2400/4160
120/240
F489190-64P
7273
319
WESTINGHOUSE
333
2400/4160
120/240
6540925
5000
320
WESTINGHOUSE
333
2400/4160
120/240
6540924
4999
321
WESTINGHOUSE
333
2400/4160
120/240
6335219
3487
322
WESTINGHOUSE
333
2400/4160
120/240
6540926
5001
323
WESTINGHOUSE
333
2400/4160
120/240
6335220
3488
ir.nnn TPANigCMPMCDC, Tn gC71 I PArIc /I n� ,ten iQQ