Loading...
HomeMy WebLinkAboutResolution - 2004-R0115 - Contract For Water Inventory Items - Western Industrial Of Lubbock - 03_04_2004Resolution No. 2004—RO115 Narch 4, 2004 Item No. 33 RESOLUTION BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF LUBBOCK: THAT the Mayor of the City of Lubbock BE and is hereby authorized and directed to execute for and on behalf of the City of Lubbock, a Contract for water inventory items — annual pricing, by and between the City of Lubbock and Western Industrial of Lubbock, Texas, and related documents. Said Contract is attached hereto and incorporated in this resolution as if fully set forth herein and shall be included in the minutes of the City Council. Passed by the City Council this 4th day of MARC ACDOWAL, MAYOR ATTEST: Rebecca Garza, City Secretary APPROVED AS TO CONTENT: v� Victor Kilmart Purchasing Manager APPROVED AS TO FORM: ^ M. Knight Assistant City Attorney gs/ccdocs/Contract-Westem Industrial.res Feb. 21, 2004 %, , Y r ` ITB #20M3/DC, Primary Vendor Contract for Water Inventory Items - Annual Pricing Resolution No. 2004—RO115 PRIMARY VENDOR CONTRACT March 4, 2004 Item No. 33 STATE OF TEXAS 9 COUNTY OF LUBBOCK 9 This contract, (the "Contract"), effective as of March 4, 2004, (the "Effective Date"), is by and between the City of Lubbock, (the "City"), a Texas Home Rule Municipal Corporation, and Western Industrial, a Texas corporation, whose principal place of business is located at Lubbock, Lubbock county, Texas (the "Contractor"). WITNESSETH WHEREAS, the City requires a contractor to procure, warehouse, and deliver, on request, repair parts for the City Water Department, and WHEREAS, the Contractor is qualified and willing to procure, warehouse, and deliver, on request, repair parts for the City Water Department, and WHEREAS, the City desires to contract with Contractor to provide the service, and NOW THEREFORE, for and in consideration of the terms, covenants and conditions set forth in this Contract, the City and Contractor hereby agree as follows: ARTICLE l ITEM The term of this Contract commences on the Effective Date and continues without interruption for a term of one (1) year from and after the Effective Date. The term may be extended for two (2) additional one (1) year terms with the written consent of both parties. ARTICLE II COMPENSATION Contractor shall be paid in accordance with their bid submitted on November 18, 2003 for 1TB #200-03/DC. ARTICLE III TERMINATION A. General. City may terminate contract, for any reason, upon ninety- (90) days written notice to Contractor. B. Termination and remedies. In the event the Contractor breaches any term and/or provision of this Contract the City shall be entitled to exercise any right or remedy available to it at law or equity, including without limitation, immediate termination of this Contract and assertion of action for damages and/or injunctive relief. The exercise of any right or remedy shall not preclude the concurrent or subsequent exercise of any other right or remedy and all other rights and remedies shall be cumulative. 200-03 / DCITBBestVal. doc 62 ITB #200-03/DC, Primary Vendor Contract for Water Inventory items - Annual Pricing ARTICLE IV REPRESENTATIONS AND WARRANTIES A. Existence. Contractor is a corporation duly organized, validly existing, and in good standing under the laws of the State of Texas and is qualified to carry on its business in the State of Texas. B. Corporate Power. Contractor has the corporate power to enter into and perform this Contract and all other activities contemplated hereby. C. Authorization. Execution, delivery, and performanceof this Contract and the activities contemplated hereby have been duly and validly authorized by all the requisite corporate action on the part of the Contractor. This Contract constitutes legal, valid, and binding obligations of the Contractor and is enforceable in accordance with the terms thereof. D. Contractor. Contractor maintains a professional staff and employs, as needed, other qualified specialists experienced in procuring, warehousing, and delivering repair parts, and are familiar with all laws, rules, and regulations, both state and federal, including, without limitation the applicable laws, regarding the activities contemplated hereby. E. Performance. Contractor will and shall conduct all activities contemplated by this Contract in a good and workmanlike manner, and comply with all laws, rules, and regulations, both state and federal, relating to procuring, warehousing, and delivering repair parts, as contemplated hereby. if any of the activities of the Contractor, or omissions of the activities required herein, shall cause, in whole or in part, liability or loss on the part of the City, it shall be deemed that the Contractor did not perform said activities (or omitted the performance of said activities) in a good and workmanlike manner. ARTICLE V SCOPE OF WORK A. General. Contractor shall procure, warehouse, and deliver to the City of Lubbock Central Warehouse all items listed in BID FORM attached hereto, on an as needed basis all repair parts for the City's Water Department on request. B. Out of stock items. In the event the Contractor cannot supply the City regularly stocked products within twenty-four (24) hours, Contractor shall give immediate notice to the City of Lubbock Purchasing Manager and City may obtain the product from another source. The Contractor will be charged the difference in price between the price paid by the City and the Contract price, plus freight, if any. The City will not charge the Contractor for items purchased from other sources when the outage is caused by nationwide outages or manufacturer recalls. C. Quantities. The Contractor shall maintain all items listed in BID FORM at a minimum fill rate of 99%. Acceptance of alternate items or products by City will not constitute compliance with the minimum fill rate requirement, with the exception of the product manufacturer's inability to fill an order. D. Minimum quantities requested by City. The Contractor agrees that the City has made no representation, guaranty, or commitment that the City will purchase any minimum quantity of products under this Contract. The Contractor further agrees that any inventories, residual or otherwise, which the Contractor may establish or which may otherwise arise from the Contractor's performance under this Contract, shall be at the sole risk and responsibility of the Contractor. 200-03/DCITBBestVal.doc 63 ITB #200-03/DC, Primary Vendor Contract for Water Inventory Items - Annual Pricing E. The City Contract Manager as needed shall schedule periodic performance meetings. The intent of the meetings will be to review day-to-day performance of the Contractor's services. The meeting shall include City personnel and Contractor's account representative. F. Time. It is agreed and understood that time is of the essence for the performance of this Contract, and failure by Contractor to meet the time specifications of this Contract will cause Contractor to be in default of this Contract. G. Delivery. Deliveries will be made directly to the City of Lubbock Central Warehouse, 302 Municipal Drive, Lubbock, Texas, and to other locations as required from time to time. Contractor shall fill routine requests within six (6) hours of City's request. Emergency orders, defined as disruption related to an essential service when supplies/services are needed for immediate use in work which may vitally affect the public health, welfare, or safety, placed during standard business hours within two (2) hours after receipt of order. Delivery of emergency items outside of standard business hours shall be accomplished as mutually agreed upon by the Contractor and the City's Representative. H. Account representative. Contractor shall assign an Account Representative whose function shall be to facilitate all day-to-day business transactions. The Account Representative shall conduct a service visit to the City each Monday, Wednesday, and Friday at 8:00 a.m. or as required by the City. An alternative Account Representative shall provide the same service when the primary is unavailable for any reason. At no time shall the visitation schedule be disrupted. I. Reports. Contractor shall provide a monthly report of the inventory listing all items: on - hand, ordered by City, delivered by Contractor, and ordered. J. Material Safety Data Sheets. Contractor shall provide Material Safety Data Sheets (MSDS) for all chemicals to comply with provisions of the Texas Hazard Communication Act, Title 6, Subchapter D, Chapter 502, Texas Health and Safety Code Ann. (This Act is corollary to OSHA Standard 29 CRF 1910.1200, which is generally known as the Right to Know Law.). K. Product Guarantee. Contractor guarantees equipment or product offered will meet or exceed specifications identified in this bid invitation. The Contractor shall, upon request, replace any equipment or product proved to be defective and make any and all adjustments necessary without any expense to the City. If at any time, the equipment or product cannot satisfactorily meet the requirements of the specifications, the Contractor shall upon written request from the City, promptly remove such equipment or product without any further expense to the City. L. Right of Inspection. City shall have the right to inspect the goods at delivery before accepting them. M. Invoices. Contractor shall submit separate invoices, in duplicate, on each purchase order or purchase release after each delivery. Invoices shall indicate the purchase order or purchase release number and the supply agreement number if applicable. Invoices shall be itemized and transportation charges, if any, shall be listed separately. A copy of the bill of lading, and the freight waybill when applicable, shall be attached to the invoice. Mail to Accounts Payable, City of Lubbock, P.O. Box 2000, Lubbock, Texas 79457. Payment shall not be due unless and until the Seller shall not be in default under the terms of this Contract, and until the above instruments are submitted after delivery. 200-031DQTUestVal.doc 64 ITB #200-0310C, Primary Vendor Contract for Water Inventory Items - Annual Pricing ARTICLE VI INDEPENDENT CONTRACTOR STATUS Contractor and City agree that Contractor shall perform the duties under this Contract as an independent contractor. The Contractor has the sole discretion to determine the manner in which the services are to be performed. ARTICLE Vill EMPLOYMENT OF AGENTS Contractor may employ or retain agents, consultants, contractors, or third parties, to perform certain duties of Contractor under this Contract provided that Contractor is in no event relieved of any obligation under this Contract. Any such agents, contractors, or third parties retained and/or employed by Contractor shall be required to carry, for the protection and benefit of the City and Contractor and naming said third parties as additional insureds, insurance as described in Article VI of this Contract. ARTICLE IX CONFIDENTIALITY Contractor shall retain all information received from or concerning the City and the City's business in strictest confidence and shall not reveal such information to third parties without prior written consent of the City, unless otherwise required by law. ARTICLE X INDEMNITY City of Lubbock shall not be liable or responsible for, and shall be saved and held harmless by Contractor from and against any and all suits, actions, losses, damages, claims, or liability of any character, type, or description, including all expenses of litigation, court costs, and attorney's fees for injury or death to any person, or injury to any property, received or sustained by any person or persons or property, arising out of, or occasioned by, directly or indirectly, in whole or in part, the performance of Contractor under this agreement, including claims and damages arising in whole or in part from the negligence of City of Lubbock. It is the expressed intent of the parties to this Agreement that the indemnity provided for in this section is an indemnity extended by Contractor to indemnify and protect City of Lubbock from the consequences of City's own negligence, whether that negligence is the sole or contributory cause of the resultant injury, death, or damage. ARTICLE XI COMPLIANCE WITH APPLICABLE LAW Contractor shall comply with all applicable federal, state and local laws, statutes, ordinances, rules and regulations relating, in any way, manner or form, to the activities under this Contract, and any amendments thereto. 200.03/ DCITBBestVat.doc 65 lTB #200-03/DC, Primary Vendor Contract for Water Inventory Items - Annual Pricing ARTICLE XII NOTICE A. General. Whenever notice from contractor to City or City to Contractor is required or permitted by this Contract and no other method of notice is provided, such notice shall be given by (1) actual delivery of the written notice to the other party by hand, (2) facsimile, or other reasonable means (in which case such notice shall be effective upon delivery), or (3) by depositing the written notice in the United States mail, properly addressed to the other party at the address provided in this article, registered or certified mail, return receipt requested, in which case such notice shall be effective on the third business day after such notice is so deposited. B. Contractor's Address. Contractor's address and numbers for the purposes of notice are: Attn: Kim McGuire Western Industrial 2406 Erskine Lubbock, Texas 79415 Telephone: (806) 765-9511 Facsimile: (806) 765-7070 City's Address. The City's address and numbers for the purposes of notice are: City of Lubbock Attn: Diana Caudillo P. 0. Box 2000 1625 13th Street Lubbock, Texas 79457 Telephone: (806)775-2169 Facsimile: (806) 775-2164 D. Change of Address. Either party may change its address or numbers for purposes of notice by giving written notice to the other party, referring specifically to this Contract, and setting forth such new address or numbers. The address or numbers shall become effective on the 15th day after such notice is effective. ARTICLE XIII MISCELLANEOUS A. Captions. The captions for the articles and sections in this Contract are inserted in this Contract strictly for the parties' convenience in identifying the provisions to this Contract and shall not be given any effect in construing this Contract. B. Audit. Contractor shall provide access to its corporate books and records to the City. The City may audit, at its expense and during normal business hours, Contractor's books and records with respect to this Contract between the Contractor and City. C. Records. Contractor shall maintain records that are necessary to substantiate the services provided by the Contractor. D. Assignability. Contractor may not assign this Contract without the prior written approval of the City. 200-03 / DC1TBBestVal. doc M. ITB #200-0310C, Primary Vendor Contract for Water Inventory Items - Annual Pricing E. Successor and Assigns. This Contract binds and inures to the benefit of the City, Contractor, and their respective successors, legal representatives, and assigns. F. Construction and Venue. THIS CONTRACT SHALL BE GOVERNED BY AND CONSTRUED IN ACCORDANCE WITH THE LAWS OF THE STATE OF TEXAS. THE PARTIES HERETO HEREBY IRREVOCABLY CONSENT TO THE EXCLUSIVE JURISDICTION AND VENUE OF THE COURTS OF THE STATE OF TEXAS, COUNTY OF LUBBOCK, FOR THE PURPOSES OF ALL LEGAL PROCEEDINGS ARISING OUT OF OR RELATING TO THIS CONTRACT OR THE ACTIONS THAT ARE CONTEMPLATED HEREBY. G. Severability. If any provision of this Contract is ever held to be invalid or ineffective by any court of competent jurisdiction with respect to any person or circumstances, the remainder of this Contract and the application of such provision to persons and/or circumstances other than those with respect to which it is held invalid or ineffective shall not be affected thereby. H. Amendment. No amendment, modification, or alteration of the terms of this Contract shall be binding unless such amendment, modification, or alteration is in writing, dated subsequent to this Contract, and duly executed by the Contractor and City. I. Entire Agreement. This Contract, including Exhibit A hereto, contains the Entire Contract between the City and Contractor, and there are no other written or oral promises, conditions, warranties, or representations relating to or affecting the matters contemplated herein. 200-031DCITBBestVa1.doc 67 iTB #200-0a/DC, Primary Vendor Contract for Water Inventory hems - Annual Pricing EXECUTED as of the Effective Date hereof. CITY OF LUBBOCK By MAkC MCDOUGAL, MAYOR // Title: �s�� a rch f%% f . ATTEST: E�,eS--- Rebecca Garza City Secretary APPROVED AS TO CONTENT: Victor Urri n Purchasing Manager APPROVED AS TO FORM: 200-03 MCITBBestVat. doc ITS 0200-0310C. Primary Venda contract for water Inveni«y Items - annual Pridny SUBMIT TO: o CITY OF LUBBOCK CITY OF LUBBOCK TEXAS PURCHASING DEPARTMENT (( 1 1625 13TH STREET, RM L04 LUBBOCK, TX 7MI -3830 AN EQUAL OPPORTUNITY INVITATION TO B i D CONTACT PERSON: Diana Caudillo EMPLOYER #200-03/DC TEL: 806.775.2167 FAX: 806.775.2164 http://purchasing.cf.lubbock.tx.us TITLE: SUBMITTAL DEADLINE: PRIMARY VENDOR CONTRACT FOR WATER INVENTORY ITEMS- November 11, 2003, 2:00 PM CST ANNUAL PRICING PRE BID DATE, TIME AND LOCATION: Any bids received after the time and date (isted above, regardless of the mode of detfwry, shall be / 0• 0- 0 3 : O O , M- RM /07 1returned unopened. RESPONDENT NAME: S e r a IF RETURNING AS A "NO BiD", PLEASE COMPLETE AND RETURN THE "STATEMENT OF NO BID". MAILING ADDRESS: ''/ 0 6 - 07 - ST TE - ZIP: / THE CITY OF LUBBOCK RESERVES THE RIGHT TO ACCEPT OR REJECT ANY AND ALL BIDS fJ O G ' 9 IC 1N WHOLE OR IN PART AND WAIVE ANY INFORMALITY IN THE COMPETITIVE BID PROCESS. FURTHER, THE CITY RESERVES THE RIGHT TO ` TELEPHONE NO: ENTER INTO ANY CONTRACT DEEMED TO BE IN THE BEST INTEREST OF THE CITY. 0 6 6 s^ - 9 .r / IT IS THE INTENT AND PURPOSE OF THE CRY OF LUBBOCK THAT THIS FAX NO: 6 S REQUEST PERMITS COMPETITIVE BIDS. IT iS THE BIDDER'S RESPONSIBILITY 0 20 TO ADVISE THE CITY OF WBBOCK PURCHASING MANAGER IF ANY LANGUAGE, REQUIREMENTS, ETC., OR ANY COMBINATIONS THEREOF, E-MAIL: INADVERTENTLY RESTRICTS OR LIMITS THE REQUIREMENTS STATED IN THIS >`� C / G s'3ilvd, com ITB TO A SINGLE SOURCE SUCH NOTIFICATION MUST BE SUBMITTED IN WRMNG AND MUST BE RECEIVED BY THE PURCHASING MANAGER NO LATER FEDERAL AX ID N0. OCIAL SECURITY NO. 8 A 7 s� THAN FIVE (5) BUSINESS DAYS PRIOR TO THE ABOVE SUBMITTAL DEADLINE. THE BIDDER HEREBY ACKNOWLEDGES RECEIPT OF AND AGREES iTS BID IS BASED ON THE FOLLOWING ADDENDA: #1 ^ M#2)6r #3 X #4 #5 (Please initial) The City of Lubbock Charter states that no officer or employee of the City can benefit from any contract, job, work or service for the municipality or be interested in the sate to the City of any supplies, equipment, material or artides purdrased. Will any officer or employee of the City, or member of their immediate family, benefit from the award of this bid to the above firmt_ YES NO IN COMPLIANCE WITH THIS SOLICITATION, THE UNDERSIGNED BIDDER HAVING EXAMINED THE INVITATION TO BID AND SPECIFICATIONS, AND BEING FAMILIAR WITH THE CONDITIONS TO BE MET, HEREBY SUBMITS THE FOLLOWING BiD FOR FURNISHING THE MATERIAL, EQUIPMENT, LABOR AND EVERYTHING NECESSARY FOR PROVIDING THE ITEMS LISTED ON THE ATTACHED BID FORM AND AGREES TO DELIVER SAID ITEMS AT THE LOCATIONS AND FOR THE PRICES SET FORTH ON THE BID FORM. AN INDIVIDUAL AUTHORIZED TO BIND THE COMPANY MUST SiGN THE FOLLOWING SECTION. FAILURE TO EXECUTE THIS PORTION MAY RESULT IN BID REJECTION. By my signature i certify that this offer is made without prior understanding, agreement, or connection with any corporation, firm, business entity, or person submitting an offer for the same materials, supplies, equipment, or service(s), and is in all respects fair and without collusion or fraud. I further agree that if the offer is accepted, the offeror will convey, sell, assign, or transfer to the City of Lubbock all right, title, and interest Wand to all causes of action it may now or hereafter acquire under the Anti-trust laws of the United States and the State of Texas for price fixing relating to the particular commodity(s) or service (s) purchased or acquired by the City of Lubbock. At the ity's discretion, such assignment shad be made and become effective at the time the City tenders final payment to the vendo 7� ho6orized Signature Title A; Print/Type Name Date THiS FORM MUST BE COMPLETED AND RETURNEDiNITH YOUR RESPONSE. 200-03/ DCITBBestVal.doc ITB #200-03/DC, Addendum #1 BID FORM Primary Vendor Contract for Water Inventory Items - Annual Pricing CITY OF LUBBOCK, TEXAS ITB #200-03/DC In compliance with the Invitation to Bid #200-03/DC, the undersigned Bidder having examined the Invitation to Bid and Specifications, and being familiar with the conditions to be met, hereby submits the following Bid for furnishing the material, equipment, tabor and everything necessary for providing the items listed below and agrees to deliver said Items at the locations and for the prices set forth on this form. The Invitation to Bid #200.03/DC is by reference incorporated in this contract. The Bid Form must be completed in blue or black Ink. Item # Description U/M Estimated Annual Usage Unit Price Extended Price 3 FIRE HYDRANTS SHALL BE STANDARD AWWA C-502 HYDRANTS, IRON BODY, BRONZE EA 3 '1 MOUNTED THROUGHOUT INCLUDING DRAIN SEAT RING, AND SHALL BE DESIGNED FOR A WORKING PRESSURE OF 150 POUNDS PER SQUARE INCH. THE FIRE HYDRANTS SHALL BE THE TRAFFIC MODEL TYPE AND SHALL HAVE A 5-1 /4" VALVE OPENING, TWO 2-1/2 INCH HOSE NOZZLES AND ONE 4-INCH STEAMER NOZZLE, WITH 4 THREADS PER INCH AND A CREST TO CREST DIMENSION OF 4.995 INCHES. THE HYDRANTS SHALL BE FOR 6-INCH MAINS AND SHALL HAVE A M.J. CONNECTION, AND SHALL BE FOR 3 FOOT BURY. THE HYDRANTS SHALL BE CLOW MEDALLION, AMERICAN DARLING MODEL B-84-B, M Ft H STYLE 129-09 OR MUELLER CENTURION. OPERATING NUTS SHALL BE 1-1 /2 INCH PENTAGONS MEASURED TO A POINT. THE HYDRANTS SHALL BE PAINTED ORANGE. COL Warehouse #421030000 200-03/DCAddend.doc ITB #200-031DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 4 FIRE HYDRANTS SHALL BE STANDARD AWWA C-502 HYDRANTS, IRON BODY, BRONZE EA 2 �.1�•' 1� 7 `f , r. n� �g `'T `� MOUNTED THROUGHOUT INCLUDING DRAIN SEAT RING, AND SHALL BE DESIGNED FOR A WORKING PRESSURE OF 150 POUNDS PER SQUARE INCH. THE FIRE HYDRANTS SHALL BE THE TRAFFIC MODEL TYPE AND SHALL HAVE A 5-1/4" VALVE OPENING, TWO 2-1/2 INCH HOSE NOZZLES AND ONE 4-INCH STEAMER NOZZLE, WITH 4 THREADS PER INCH AND A CREST TO CREST DIMENSION OF 4.995 INCHES. THE HYDRANTS SHALL BE FOR 6-INCH MAINS AND SHALL HAVE A M.J. CONNECTION, AND SHALL BE FOR 3-1/2 FOOT BURY. THE HYDRANTS SHALL BE CLOW MEDALLION, AMERICAN DARLING MODEL B-84-B, M ft H STYLE 129-09 OR MUELLER CENTURION. OPERATING NUTS SHALL BE 1-1/2 INCH PENTAGONS MEASURED TO A POINT. THE HYDRANTS SHALL BE PAINTED ORANGE. COL Warehouse #421030001 5 FIRE HYDRANTS SHALL BE STANDARD AWWA C-502 HYDRANTS, IRON BODY, BRONZE EA 12 q �1 /0"51 !0. 40 MOUNTED THROUGHOUT INCLUDING DRAIN SEAT RING, AND SHALL BE DESIGNED O10� o�O FOR A WORKING PRESSURE OF 150 POUNDS PER SQUARE INCH. THE FIRE HYDRANTS SHALL BE THE TRAFFIC MODEL TYPE AND SHALL HAVE A 5-1/4" VALVE OPENING, TWO 2-1/2 INCH HOSE NOZZLES AND ONE 4-INCH STEAMER NOZZLE, WITH 4 THREADS PER INCH AND A CREST TO CREST DIMENSION OF 4.995 INCHES THE HYDRANTS SHALL BE FOR 6-INCH MAINS AND SHALL HAVE A M.J. CONNECTION, AND SHALL BE FOR 4 FOOT BURY. THE HYDRANTS SHALL BE, AMERICAN DARLING MODEL B-84-B, M bt H STYLE 129-09 OR MUELLER CENTURION. OPERATING NUTS SHALL BE 1-1/2 INCH PENTAGONS MEASURED TO A POINT. THE HYDRANTS SHALL BE PAINTED ORANGE_ . COL Warehouse #421030002 6 FIRE HYDRANTS WIOBRONZE EA 50 THROUGHOUT INCLUDING RAN SEAT RING, AND SHALL BE DESIGNED MOUNTED T FOR A WORKING PRESSURE OF 150 POUNDS PER SQUARE INCH. THE HYDRANTS SHALL BE THE TRAFFIC MODEL TYPE AND SHALL HAVE A 5-1/4" VALVE OPENING, TWO 2-1/2 INCH HOSE NOZZLES AND ONE 4-INCH STEAMER NOZZLE, WITH 4 THREADS PER INCH AND A CREST TO CREST DIMENSION OF 4.995 INCHES. THE HYDRANTS SHALL BE FOR 6-INCH MAINS AND SHALL HAVE A M.J. CONNECTION, SHALL BE FOR 4-1/2 FOOT BURY. THE HYDRANTS SHALL BE CLOW MEDALLION, AMERICAN DARLING MODEL B-84-B, M fr H STYLE 129-09 OR MUELLER CENTURION. OPERATING NUTS SHALL BE 1-1/2 INCH PENTAGONS MEASURED TO A POINT. THE HYDRANTS SHALL BE PAINTED ORANGE. COL Warehouse #421030003 200-031DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 12 6 IN. VCT SEWER TILE, PEP (PLAIN END PIPE) WITH PLASTIC COUPLING INCLUDING EA 70 �, �(� AID-7-CO GASKET. VCT SEWER TILE SHOULD CONFORM TO ASTM C-700 AND C-425 SPECIFICATIONS. 61N VCT SEWER TILE COMES IN 5FT (NOMINAL) LENGTHS. COL Warehouse #463020011 15 6 IN CLAY X 6 IN Cl/PVC NONSHEAR SEWER ADAPTER COUPLING NON EA 60 SHEAR COUPLINGS FOR WASTEWATER LINES SHALL BE A MOLDED UNIT CONSISTING OF A FIBERGLASS INSERT SURROUNDED BY ELASTOMREIC �� •�� ,! �n'• "1 PVC. THE COUPLING SHALL BE SUPPLIED WITH 301 STAINLESS STEEL STRAPS AND 304 STAINLESS STEEL SCREWS. DFW PLASTICS MODEL DFW02-66NS OR APPROVED EQUAL COL Warehouse #463020017 16 8 IN CLAY X 8 IN CLAY NONSHEAR SEWER ADAPTER COUPLING. NONSHEAR COUPLING FOR WASTEWATER LINES SHALL A MOLDED UNIT CONSISTING OF A EA 1 3D.i7 30• 17 FIBERGLASS INSERT SURROUNDED BY ELASTOMERIC PVC. THE COUPLING SHALL BE SUPPLIED WITH 301 STAINLESS STEEL STRAPS AND 304 STAINLESS STEEL SCREWS. DFW PLASTICS MODEL DFW01-88NS OR APPROVED EQUAL COL Warehouse #463020022 17 8 IN CLAY X 8 IN Cl/PVC NONSHEAR SEWER ADAPTER COUPLING NONSHEAR COUPLING FOR WASTEWATER LINES SHALL BE A MOULDED UNIT CONSISTING OF A EA 12 ' '� •�� ��, (p1.� FIBERGLASS INSERT SURRONDED BY ELASTOMERIC PVC. THE COUPLING SHALL BE SUPPLIED WITH 301 STAINLESS STEEL STRAPS AND 304 STAINLESS STEEL SCREWS. DFW PLASTICS MODEL DFW02-88NS OR APPROVED EQUAL COL Warehouse #463020023 18 81N Cl/PVC X 81N Cl/PVC NONSHEAR SEWER ADAPTER COUPLING NONSHEAR COUPLING FOR WASTEWATER LINES SHALL BE A MOLDED UNIT CONSISTING OF A EA 20 (�CQ 677 531 FIBERGLASS INSERT SURROUNDED BY ELASTOMERIC PVC. THE COUPLING SHALL BE SUPPLIED WITH 301 STAINLESS STEEL STRAPS AND 304 STAINLESS STEEL SCREWS. DFW PLASTICS MODEL DFW 56-88NS OR APPROVED EQUAL. COL Warehouse #463020024 19 4 IN Cl/PVC X 4 IN Cl/PVC NONSHEAR SEWER ADAPTER COUPLING. NONSHEAR COUPLING FOR WASTEWATER LINES SHALL BE A MOLDED UNIT CONSISTING OF A EA 50 IQ .,� o 1 � o � 0 FIBERGLASS INSERT SURROUNDED BY ELASTOMERIC PVC. THE COUPLING SHALL BE SUPPLIED WITH 301 STAINLESS STEEL STRAPS AND 304 STAINLESS STEEL SCREWS. DFW PLASTICS MODEL DFW56-44NS OR APPROVED EQUAL. COL Warehouse #463020025 20 10"SEWER PIPE ADAPTER (OR FLEX COUPLING OR CT ADAPTER --ALL THE SAME) EA 8 D CLAY PIPE TO PVC OR CAST IRON PIPE COL Warehouse #463020027 ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 21 12"SEWER PIPE ADAPTER (OR FLEX COUPLING OR CT ADAPTER ALL THE SAME) CLAY EA 1 PIPE TO PVC OR CAST IRON PIPE COL Warehouse #463020028 23 ADAPTER TO TIE 4" AND 3" CAST IRON SEWER PIPE TOGETHER. EA 200 n COL Warehouse #463020034 24 "ADAPTER TO 3" AND 3" CAST IRON SEWER PIPE TOGETHER. EA 72 1, 77 COL Warehouse #463020035 4" PVC -PVC BLACK SEW ADAPTER DFW #56-44 25 EA 720 O69 , i �� liQc�• �,e0 COL Warehouse #463020036 26 4" PVC -CLAY BLACK SEW ADAPTER DFW #02-44 EA 1,100 �,.� �j d�, Jr' 3•6D COL Warehouse #46r3020037 27 6" PVC -PVC BLACK SEW ADAPTER DFW #56-66 EA 50 1.�, 7 � n , ; �� COL Warehouse #463020038 ,� 28 6" PVC -CLAY BLACK SEW ADAPTER DFW #02-66 EA 80 �i 73 , I 3�g T (� COL Warehouse #463020039 • • 35 41N PVC COUPLING SXS EA 180 COL Warehouse #473010058 39 11N. X 3/41N. AWWA BRASS BUSHING. CORPORATION STOP THREADS FORD# BBAA- EA 5 �J• LQ� %� •� 43, MUELLER# H-10036 COL Warehouse #473020024 45 6 IN. BELL JOINT CLAMP FOR 6 IN. CLASS 150 CAST IRON PIPE. DRESSER STYLE 60 EA 1 OR APPROVED EQUAL. COL Warehouse #473020049 46 31N. X 7-1 /21N. FULL CIRCLE REPAIR CLAMP. BOLTS TO BE ALLOY AND NOT LESS EA 50 3� g 3 ! to q l • 50 THAN 1 /21N. DIAMETER. TO BE USED ON 3 IN. CLASS 150 PIPE WITH OUTSIDE DIAMETER OF 3.96-4.25 SMITH-BLAIR 226 OR APPROVED EQUAL. NOTE: TAPER GASKET ONLY COL Warehouse #473020057 47 CLAMP. 0 D NOT LTS TO BE LOW l00DN UDIAMETER.LL CIRCLE RTO EA 45 L4 5t) LESS THAN 11 21NN. BE USED ON 4EPAIR N. CLASS 0 PIPE. RANGE 4.74-5.57. ROCKWELL NO. 227-047007-000, FORD F2-557-7.5 OR APPROVED EQUAL. NOTE: TAPER GASKET ONLY COL Warehouse #473020058 200-03/DCAddend.doc ITB #200-03/DC. Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage, 48 61N. X 121N. FULL CIRCLE REPAIR CLAMP. BOLTS TO BE LOW ALLOY AND NOT LESSEA 45 THAN 1 /21N. DIAMTER. TO BE USED ON 6 IN. CLASS 150 PIPE WITH OUTSIDE DIAMTER OF 6.84-7.64. SMITH-BLAIR SUPER RANGE NO. 227-069012-000, FORD FS2-764X12.5 OR APPROVED EQUAL. NOTEJAPER GASKET ONLY. COL Warehouse #473020059 49 BIN. X 121N. FULL CIRCLE DOUBLE BAND REPAIR CLAMP BOLTS TO BE PLATED OR EA 18 �� •�� `'—� �$ . f� LOW ALLOY NOT LESS THAN 5/81N DIAMETER. TO BE USED ON 8 IN. PIPE WITH OUTSIDE DIAMETER OF 8.99-9.79. ROCKWELL # 227-090512-000, JCM, # 102-0905- 12 FORD F2-979-12-5 OR APPROVED EQUAL. COL Warehouse #473020060 50 101N. X 151N. FULL CIRCLE REPAIR CLAMP FOR CLASS 150 PIPE. OUTSIDE DIAMETER EA 7 Q 1 p •(�� t I ] —�3• 11.04-12.241N..SMITH-GLAIR-N0.227-111015-050, FORD F2-1184-15 OR APPROVED EQUAL. COL Warehouse #473020061 51 121N. X 121N. FULL CIRCLE REPAIR CLAMP, SLEEVE TO BE MADE OF STAINLESS EA 1 2 STEEL. BOLTS TO BE LOW ALLOY AND NOT LESS THAN 1 /2 IN. DIAMETER. TO BE USED ON 12 IN. CLASS 100 ROUGH TRANSITE PIPE WITH OUTSIDE DIAMETER OF 13.45 IN. SMITH-BLAIR NO. 226-134012-000 , JCM 101-1340-12 OR APPROVED EQUAL. COL Warehouse #473020063 52 21N. FULL CIRCLE REPAIR CLAMP. 21N. X 7-1/21N. 0. D. 2.35-2.63. ROCKWELL NO. EA 170 ajLO�/�g• 5� 226-00023807-000, JCM 101-0238 x 7 FORD F1-263-7.5 OR APPROVED EQUAL. COL Warehouse #473020067 53 2-1 /41N. FULL CIRCLE REPAIR CLAMP. O.D. 2.70-3.00. (NOM. PIPE SIZE 2 1 /2 IN.) EA 50.o`�g ,1 JCM #101-275-7, ROCKWELL#226-09027507-000, FORD F1-300-7.5" OR APPROVED' EQUAL. COL Warehouse #473020068 54 1X3 REPAIR CLAMP REDI EA 10 3-13 37.3t� COL Warehouse #473020072 55 2 IN. REDI REPAIR CLAMP. O.D. 2.35-2.50. SMITH-BLAIR CAT. NO.245-0238-0300 EA 12 �.. JCM 110-0238-3 FORD FSL 238-3 OR APPROVED EQUAL TO BE APPROVED BY WATER DEPT ENGINEER. COL Warehouse #473020073 200-03/DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 56 21N. X 3/41N. SERVICE SADDLE, SINGLE STRAP, DUCTILE IRON BODY, TAPPED 3/4" 30 �2 (�. DJ 0104, 9D AWWA CORPORATION STOP THREADS. TO BE USED ON 2" STANDARD STEEL AND 2" CAST IRON PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAP TO BE PLATED. O.D. RANGE 2.35 TO 2.56 ROCKWELL NO. 311-025607-000, JCM #401-0238X07 OR APPROVED EQUAL. COL Warehouse #473020080 57 21N. X 11N. SERVICE SADDLE, DUCTILE IRON BODY, SINGLE STRAP, TAPPED 1" AWWA EA 40 .g,; Q! CORPORATION STOP THREADS. TO BE USED ON 2" STANDARD STEEL AND 2" CAST IRON PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAP TO BE PLATED. O.D. RANGE 2.35 TO 2.56 ROCKWELL NO. 311-025609-000 OR APPROVED EQUAL. COL Warehouse #473020081 58 31N: X 3/41N. SERVICE SADDLE, DUCTILE IRON BODY, SINGLE STRAP, TAPPED 3/4" EA 30 ' AWWA CORP. STOP THREADS. TO BE USED ON 3" CLASS 150 ROUGH BARREL O ASBESTOS CEMENT PIPE. CLAMP TO HAVE NEOPRENE GASKET. O.D. RANGE 3.74 TO 4.55 ROCKWELL NO. 311-045507-000 OR APPROVED EQUAL. COL Warehouse #473020082 59 31N. X 1 IN. SERVICE SADDLE, DUCTILE IRON BODY, SINGLE STRAP, TAPPED 1" AWWA EA 100 CORPORATION STOP THREADS. TO BE USED ON 3" CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE. CLAMPS TO HAVE NEPRENE GASKET. STRAP TO BE PLATED. O.D. RANGE 3.74 TO 4.55 ROCKWELL NO. 311-045509-000 OR APPROVED EQUAL. COL Warehouse #473020083 60 41N. X 21N. SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 2" IRON EA 40 Ile 90 ` &-b . OD PIPE THREADS. TO BE USED ON 4" CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAPS TO BE PLATED. O.D. RANGE 4.74 TO 5.63 ROCKWELL NO. 313-056314-000 OR APPROVED EQUAL. COL Warehouse #473020088 61 SERVICERAP EA 40 p ' _1 (� �-l5' AND TAPPED 2 PIPE THREADS. CLAMP TO HAVE A NEOPRENE, OR OTHER •�$ APPROVED MATERIAL, GASKET. STRAP SHOULD BE CORROSION RESISTANT. SADDLES TO BE USED ON CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE, CLASS 150 DUCTILE IRON PIPE AND C900 PVC PIPE. O.D.RANGE SHALL BE AT LEAST 6.90 TO 7.37. COL Warehouse #473020091 200-03/DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 62 DUCTILE81N. X 21N. SERVICE SADDLE, I.P. EA 50 Q� �� �j. �� THREAD TO BE USED ON 8" CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE. a' `1 CLAMP TO HAVE NEOPRENE GASKET. STRAPS TO BE PLATED. O.D. RANGE 8.54 TO 10.10 ROCKWELL NO. 313-101014-000 OR APPROVED EQUAL. COL Warehouse #473020092 63 101N. X 21N. SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 2" I.P. EA 10 1 THREAD. TO BE USED ON 10" CLASS 150 CAST IRON PIPE. CLAMP TO HAVE NEOPRENE GASKETS. STRAPS TO BE PLATED. O.D. 10.64 TO 12.12 ROCKWELL NO. 313-121214-000 OR APPROVED EQUAL. COL Warehouse #473020093 64 10 IN. X 1 IN. SERVICE SADDLE SHALL HAVE A DUCTILE IRON BODY, SINGLE STRAP EA 100 �• "[ AND TAPPED 1" AWWA CORPORATION STOP THREADS. CLAMP TO HAVE A 1D NEOPRENE, OR OTHER APPROVED MATERIAL, GASKET. STRAP SHOULD BE CORROSION RESISTANT. SADDLES TO BE USED ON CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE, CLASS 150 DUCTILE IRON PIPE AND C900 PVC PIPE. O.D. RANGE SHALL BE AT LEAST 11.10 TO 12.12. COL Warehouse #473020095 65 121N X 21N SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 2" I.P. EA 18 THREAD. TO BE USED ON 12" CLASS 150 C.I. PIPE. CLAMP TO HAVE A NEOPRENE J`'f GASKET. STRAPS TO BE PLATED. O.D. RANGE 12.62 TO 14.32 ROCKWELL NO. 313- 143214-000 OR APPROVED EQUAL. COL Warehouse #473020097 66 12" X 1" REPAIR SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 1" EA 36 P� AWWA CORPORATION STOP THREADS. STRAPS TO BE PLATED. O.D. RANGE 13.14 TO 14.38 ROCKWELL NO. 331-143809-000-SMITH-BLAIR 331 OR APPROVED EQUAL. COL Warehouse #473020098 67 3" X 2" SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP TAPPED 2" IRON PIPE EA 6 13 - tel ^ qi4 ' U� THREADS, CLAMP TO HAVE NEOPRENE GASKET. STRAPS TO BE PLATED. O.D. RANGE 3.74 TO 4.55 SMITH-BLAIR NO. 313-045014-000 OR APPROVED EQUAL. COL Warehouse #473020100 68 8" X 1" SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 1" AWWA EA 360 Le 3 9S. SD CORPORATION STOP THREADS. TO BE USED ON CLASS 150 PIPE, CLAMP TO HAVE A J7 NEOPRENE GASKET. STRAP TO BE PLATED. O.D. RANGE 8.54 TO 10.10 ROCKWELL NO. 313-101009-000„POWERSEAL #3413 8'X1' CC. OR APPROVED EQUAL. COL Warehouse #473020102 200-03/DCAddend.doc a ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 69 DUCTILE TAPPED IRON EA 2 PPE THREADS, CLAMP TO HAVE NEO NEOPRENE GASKET. STRAPS TO BE PLATED. O.D. RANGE 17.40 TO 18.88 ROCKWELL NO. 313-188814-000 JCM-402-1888X4 OR APPROVED EQUAL COL Warehouse #473020104 70 16" X 1" SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 1" AWWA EA 1 �3'�d gu CORPORATION STOP THREAD, CLAMP TO HAVE NEOPRENE GASKET, STRAPS TO BE PLATED. O.D. RANGE 17.40 TO 18.88 ROCKWELL NO. 313-188809-000 OR APPROVED EQUAL. COL Warehouse #473020106 96 3/4 IN. STRAIGHT METER COUPLING. 2-1 /21N. IN LENGTH. SHALL BE MACHINED EA 400 �� . l 1, D Q Z)b INSIDE AND OUTSIDE. JAMES JONES J-130, MUELLER H-10890 , OR EQUAL TO BE • APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473020202 97 3/41N. 90 DEGREE METER COUPLING. JAMES JONES NO. J-132 OR EQUAL TO BE EA 60 3 •O� APPROVED BY PAUL NOLEN AT WATER UTILITIES. -� Off- COL Warehouse #473020203 98 EQUAL.EA MUST 1,400 r , / �, �J�`7 • Di� EQUAL BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473020204 99 1 IN. X 3-1/2 IN. LONG METER COUPLING STRAIGHT. JAMES JONES J-130 OR EA 2,500 �' . �' 2 o" APPROVED EQUAL.1 IN. WATER METER COUPLING (METER SPUD) 3 1 /2 LONG, STRAIGHT, IRON PIPE THREAD, SWIVEL METER COUPLING NUT WITH WASHER, OCTAGON BARREL. JAMES JONES J-130.FORD C-38-44-3.5 ALL OTHERS MUST BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473020205 102 23-1 /21N NO. 5 SEWER MANHOLE LID AS MANUFACTURED BY TAYLOR FOUNDRIES EA 80 PRODUCT NO. 9017 WITH LIFT BAR. NO SUBSTITUTIONS ALLOWEDI I I LIDS NEED TO QQ Qlo , l ` BE MARKED "SEWER" COL Warehouse #473020211 ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 104 METER AT THE TOP 14 X SHALL BE ROUND ITH A TAPEREDBEGINNING /2 EA 3'000 p tad vA' �� �� TO 10 1 6" OUTSIDE DIAMETER HEIGHT TO 18THE METR BOX (• SHALL BE A BROOKS PRODUCTS 2200 SERIES COMPLETE WITH A SNAP SOLID COVER OR ITS APPROVED EQUAL AND SHALL HAVE 3" X 4" PIPE SLOTS AND METER BOX SHALL BE BLACK IN COLOR. METER BOX LID SHALL BE 12 1 /2" IN DIAMETER AND DESIGNED TO FIT THE BROOKS PRODUCTS 2200 SERIES BOX OR ITS APPROVED EQUAL AND SHALL BE COMPLETE WITH COVER LIFT HOLE AND SNAP -LOCK TAB (LESS LOCKING MECHANISM) AND SHALL INCLUDE "CITY OF LUBBOCK WATER UTILITIES" MARKINGS. TO BE EVALUATED BY PAUL NOLIN COL Warehouse #473020218 112 11 /ZXCLOSE GALVANIZED NIPPLE EA 10 i) - f�7 5• 70 COL Warehouse #473020297 113 11 /2X21 /2 GALVANIZED NIPPLE EA 120 6). '�3 qv. COL Warehouse #473020299 114 1 1 /2 X 3 GAL NIPPLE EA 500 ©. 55 COL Warehouse #473020300 115 1 1 /2 X 3 1 /2 GAL NIPPLE EA 500 Q , �}�j 7�• (� COL Warehouse #473020301 116 11 /2X4 GALVANIZED NIPPLE EA 40 �' L f °Z COL Warehouse #473020302 117 11 /2X41 /2 GALVANIZED NIPPLE EA 20 / f rJ' p2 3.00 COL Warehouse #473020303 118 11 /2X5 GALVANIZED NIPPLE EA 15 COL Warehouse #473020304 119 11 /2X6 GALVANIZED NIPPLE EA 6 COL Warehouse #473020306 138 1 IN BRASS TEE EA 15 19, 5to 41A . 9 0 COL Warehouse #473020373 139 3/4 IRON PIPE TO COPPER 3/4 MALE IRON PIPE THREAD CONNECTOR. MUELLER EA 20 3, (a � 73.00 NO. H-15425, MACDONALD #4753, FORD C28-33 OR EQUAL TO BE APPROVED BY WATER DEPT ENGINEER. COL Warehouse #473020383 140 1 IN. COPPER PIPE TO 1 IN. OUTSIDE IRON PIPE THREAD CONNECTOR. JAMES EA 30 �P�� cc I p�D •� JONES J-1535, MUELLER, MACDONALD 4753 OR APPROVED EQUAL. COL Warehouse #473020385 ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 141 1 IN. FEMALE FLANGE UNION. COPPER TO INSIDE IRON PIPE THREAD, MUELLER EA 6 6.69- 33. /0., H15450 OR EQUAL. COL Warehouse #473020386 142 3/4 IN. TWO PART UNION COPPER TO COPPER. HAYS NO. 5610 OR EQUAL. EA 20 �• $� �� • J/D COL Warehouse #473020387 143 3/41N. 90 DEG. BRASS ADAPTERS, MALE IRON PIPE THREAD TO COPPER SERVICE EA 120 3.6,1 / y7D • 2 D PIPE COUPLING. JAMES JONES J-1550, MUELLER H-15530, MCDONALD 4779M, FORD L-28-33 OR APPROVED EQUAL. EQUAL TO BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473020389 146 3/41N MUELLER INSTA-TITE CONNECTION. NO. H15074 OR APPROVED EQUAL. EA 12 COL Warehouse #473020392 147 1-1 /2 IN. BRASS METER FLANGE, WITH GASKET GRINNELL OR APPROVED EQUAL EA 30 9 .O '7' �R�. COL Warehouse #473020393 aZC`� 148 2 IN. BRASS METER FLANGE, GRINELL, MIDLAND METALS OR APPROVED EQUAL. EA 50 �D,�� COL Warehouse #473020394 149 3/4 IN. BRASS 3 PART UNION. MUELLER NO. H15400 FORD C22-33 OR APPROVED EA 20 J1. (0 9L 9A • 41C) EQUAL. COL Warehouse #473020395 150 1" THREE PART UNION COUPLING. JAMES JONES J1528 OR APPROVED EQUAL. EA 30 �• ,/ 07�� •410 COL Warehouse #473020396 151CLAMP, STRAP, TAPPED IAR 20 tt ,, 11 `��• �� CORPORATION STOP THREADS TO BE USED ON2-1/2 IN. STANDARD STEEL AND 2- 1 /4 IN. CAST IRON PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAP TO BE PLATED. O.D. Range shall be 2.44-2.91. Smith Blair #311-029109. COL Warehouse #473020405 152 2-1 /21H X 3/41N SERVICE CLAMP, SINGLE STRAP, TAPPED 3/41N AWWA EA 8 T RR 6-7. CORPORATION STOP THREADS. TO BE USED ON 2-1/2 IN. CAST IRON PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAP TO BE PLATED. SMITH -GLAIR NO. 311-0291 OR APPROVED EQUAL. 0. D. RANGE 2.44 - 2.91 COL Warehouse #473020406 Item # Description U/M Estimated Unit Price Extended Price Annual Usage _ ' S3 ON NGS L BE DE FROM IPVC ETO EA 24 �' , 5(k ?7• VIRGIN COMPOUNDS CONFORMING MAT EI AIL REQU RLEMENTS OF ASTM 1784, CELL CLASSIFICATION 12454-B. FITTINGS SHALL MEET REQUIREMENTS OF ASTM D 3034. FITTINGS SHALL BE COMPATIBLE WITH SDR-35 GRAVITY SEWER PIPE AND SHALL NOT DEFLECT MORE THAN THE PIPE WHEN BEDDED AND LOADED IN THE SAME MANNER. GASKETS SHALL BE MOLDED OR EXTRUDED AND SPLICED FROM HIGH GRADE PROPERLY VULCANIZED ELASTOMERIC COMPOUND CONSISTING OF EITHER SYNTHETIC OR NATURAL RUBBER BASED POLYMER. GASKETS SHALL MEET THE REQUIREMENTS OF ASTM F 477. EACH BELL SHALL INCLUDE A GASKET INSTALLED IN PLACE. COL Warehouse #473020413 154 41N PVC PIPE PLUG - FITTINGS SHALL BE MADE FROM VIRGIN PVC COMPOUNDS EA 30 ' �� `7D •�� CONFORMING TO MATERIAL REQUIREMENTS OF ASTM 1784, CELL CLASSIFICATION 12454-B. FITTINGS SHALL MEET REQUIREMENTS OF ASTM D 3034. FITTINGS SHALL BE COMPATIBLE WITH SDR-35 GRAVITY SEWER PIPE AND SHALL NOT DEFLECT MORE THAN THE PIPE WHEN BEDDED AND LOADED IN THE SAME MANNER. GASKETS SHALL BE MOLDED OR EXTRUDED AND SPLICED FROM HIGH GRADE PROPERLY VULCANIZED ELASTOMERIC COMPOUND CONSISTING OF EITHER SYNTHETIC OR NATURAL RUBBER BASED POLYMER. GASKETS SHALL MEET THE REQUIREMENTS OF ASTM F477. EACH BELL SHALL INCLUDE A GASKET INSTALLED IN PLACE. COL Warehouse #473020415 155 61N PVC PIPE PLUG FITTINGS SHALL BE MADE FROM VIRGIN PVC COMPOUNDS CON- EA 20 �O FORMING TO MATERIAL REQUIREMENTS OF ASTM 1784, CELL CLASSIFICATION • 12454-B. FITTINGS SHALL MEET REQUIREMENTS OF ASTM D 3034. FITTINGS SHALL BE COMPATIBLE WITH SDR-35 GRAVITY SEWER PIPE AND SHALL NOT DEFLECT MORE THAN THE PIPE WHEN BEDDED AND LOADED IN THE SAME MANNER. GASKETS SHALL BE MOLDED OR EXTRUDED AND SPLICED FROM HIGH GRADE PROPERLY VULCANIZED ELASTOMERIC COMPOUND CONSISTING OF EITHER SYNTHETIC OR NATURAL RUBBER BASED POLYMER. GASKETS SHALL MEET THE REQUIREMENTS OF ASTM F 477. EACH BELL SHALL INCLUDE A GASKET INSTALLED IN PLACE. COL Warehouse # 473020416 156 81N PVC PIPE PLUG FITTINGS SHALL BE MADE FROM VIRGIN PVC COMPOUNDS CON - FORMING TO MATERIAL REQUIREMENTS OF ASTM 1784, CELL CLASSIFICATION EA 10 r1• ll 12454-B. FITTINGS SHALL MEET REQUIREMENTS OF ASTM D 3034. FITTINGS SHALL BE COMPATIBLE WITH SDR-35 GRAVITY SEWER PIPE AND SHALL NOT DEFLECT MORE THAN THE PIPE WHEN BEDDED AND LOADED IN THE SAME MANNER. GASKETS SHALL BE MOLDED OR EXTRUDED AND SPLICED FROM HIGH GRADE PROPERLY VULCANIZED ELASTOMERIC COMPOUND CONSISTING OF EITHER SYNTHETIC OR NATURAL RUBBER BASED POLYMER. GASKETS SHALL MEET THE REQUIREMENTS OF ASTM F 477. EACH BELL SHALL INCLUDE A GASKET INSTALLED IN PLACE. COL Warehouse #473020417 ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price _ _ 8 IN.X 20 IN. FULL CIRCLE REPAIR CLAMP--O.D. RANGE 8.99 TO 9.79--ROCKWELL EA Annual Usage 2 157 1Ar-p �l� _ NO. 227-09052000 , FORD F2-979-20 OR APPROVED EQUAL �l COL Warehouse #473020419 158 2" X 3" BRASS NIPPLE EA 14 N . u COL Warehouse #473020433 159 1 1/2" X 3" BRASS NIPPLE. TO BE THREADED ON BOTH ENDS EA 4 3• ;3�' 13 COL Warehouse #473020434 163 _ 4" X 3/4" SERVICE SADDLE SHALL HAVE A DUCTILE IRON BODY,DOUBLE STRAP AND 30 f 3 �O-7 5 A . IC) � 3/4" AWWA CORPORATION STOP THREADS. CLAMP TO HAVE A NEOPRENE, OR OTHER APPROVED MATERIAL GASKET. STRAP SHOULD BE CORRISON RESISTANT. SADDLES TO BE USED OB CLASS 150 ROUGH BARREL ASBETOS CEMENT PIPE, CLASS 150 DUCTILE IRON PIPE AND C900 PVC PIPE. O.D. RANGE SHALL BE AT LEAST 4.80 TO 5.27. COL Warehouse #473020444 200-03/DCAddend.doc ITB #200-0310C, Addendum 1i1 Item # Description U/M Estimated Unit Price Extended Price Annual Usa e 164 4" X 1" DOUBLE STRAP SERVICE SADDLE, DUCTILE IRON BODY TO BE TAPPED 1" EA 760 AWWA CORPORATION STOP THREADS. TO BE USED ON 4" CLASS 150 PIPE. CLAMP IS TO HAVE A NEOPRENE GASKET AND THE STRAP IS TO BE PLATED. O.D. RANGE 4.74 TO 5.63 ROCKWELL NO. 313-056309-000 OR APPROVED EQUAL. COL Warehouse #473020446 165 4" SDR 35 SEWER CAP:: ASTM D3034 WITH GASKET EA 8 �' 7q �' 3� COL Warehouse #473020461 166 3 X 4 REDUCER DRESSER COUPLING EA 12 ,� '?) (fO.3 b q COL Warehouse #473020462 168 THE SADDLE SHALL BE A FLEXIBLE SADDLE TO BE USED ON SEWER LINES UP TO 121N EA 150 al 3� 7L` INSIDE DIAMETER. TO BE MANUFACTURED OUT OF ELASTOMETRIC POLY VINYL ,�3 , CHLORIDE WITH MOLDED INSERTS AND A SKIRT TO AID IN THE SEALING PROCESS. THE BANDS SHALL BE STAINLESS STEEL AND SHALL HAVE WIGGLE TAIL CONNECTIONS. ALL MATERIALS SHALL BE TOTALLY RESISTANT TO CORROSION. INLET RANGE SHALL INCLUDE BOTH SDR 35 AND SCH 40. COL Warehouse #473020465 169 THE SADDLE SHALL BE A FLEXIBLE SADDLE TO BE USED ON SEWER LINES UP TO 121N EA 12317cX INSIDE DIAMETER. TO BE MANUFACTURED OUT OF ELASTOMETRIC POLY VINYL -� CHLORIDE WITH MOLDED INSERTS AND A SKIRT TO AID IN THE SEALING PROCESS. THE BANDS SHALL BE STAINLESS STEEL AND SHALL HAVE WIGGLE TAIL CONNECTIONS. ALL MATERIALS SHALL BE TOTALLY RESISTANT TO CORROSION. INLET RANGE SHALL INCLUDE BOTH SDR 35 AND SCH 40. COL Warehouse #473020467 171 4" PVC 90 DEG ELBOW LONG RADIUS SOLVENT WELD STANDARD RADIUS DRAIN EA 900 . �✓� nn Ot a$(D. QQ WASTE FITTINGS COL Warehouse #473020480 200-031DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 174 3" RT DRESSER COUPLING WITH O.D. UP TO 4.29 FOR OVERSIZE PIPE FOR CLASS 200 AC PIPE. EA 4 32 • Q p�Q •'7 COL Warehouse #473020487 175 4" OVERSIZE DRESSER COUPLING O.P. RANGE 4.97-5.57 EA 2 3�j• 2j • "fist COL Warehouse #473020490 176 1 INCH 90 DEGREE BRASS ADPATERS MALE IRON PIPE THREAD TO COPPER SERVICE EA 40 (p % p� �Jg •gam PIPE COUPLING. JAMES JONES#J-1550 MUELLER #H-15530 OR EQUAL TO BE . APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473620491 179 1" X 1 1!2" METER COUPLING EA 72 �f,�p ��,T� COL Warehouse #473020505 180 6X3/4 DOUBLE STRAP TAPPING SADDLE O.D. 6.84-7.60 MITH-GLAIR OR EQUAL. EA 8 1 fp•Q7 �� ,?� COL Warehouse #473020516 181 61N. X 11N. SERVICE SADDLE, DUCTILE IRON BODY, DOUBLE STRAP, TAPPED 1" EA 1,000 �(Q, �(n/, QQ AWWA CC THREADS. TO BE USED ON 6" CLASS 150 ROUGH BARREL ASBESTOS CEMENT PIPE. CLAMP TO HAVE NEOPRENE GASKET. STRAP TO BE PLATED. O.D. , RANGE 6.84 TO 7.60 COL Warehouse #473020518 :185 3" X 12" FULL CIRCLE CLAMP. BOLTS TO BE ALLOY AND NOT LESS THAN 1 /2" EA 30 n 3�j • Q DIAMETER. TO BE USED ON 3" CLASS 150 PIPE WITH OUTSIDE DIAMETER OF 3.49- �• 0�� 4.29. ROCKWELL 227-035012-000 OR APPROVED EQUAL. NOTE: NOTE TAPER GASKET ONLY COL Warehouse #473020522 186 4" X 12" FULL CIRCLE CLAMP. BOLTS TO BE LOW ALLOY AND NOT LESS THAN 1 /2" EA 16 •� 7 , a 3a n DIAMETER. TO BE USED ON 4" CLASS 150 PIPE. O.D. RANGE 4.74-5.57. ROCKWELL /• NO. 227-048012-000 NOTE: TAPER GASKET ONLY. FORD F2-557-12-5 OR APPROVED EQUAL. COL Warehouse #473020523 .187 4" RESTRAINER FORD SERIES 1300 EA 2 1+,•�� `1 '�a COL Warehouse #473020524 p�� 188 6" RESTRAINER FORD SERIES 1300 EA 6 �7• 7 ! a3 �a COL Warehouse #473020525 • 189 8" RESTRAINER FORD SERIES 1300 EA 2 COL Warehouse #473020526 1 190 10"RESTRAINER FORD SERIES 1300 EA 2 (a ?J • t��, g(� COL Warehouse #473020527 ITB #200-03/DC. Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 191 6" RESTRAINER FORD SERIES 1350 EA 3 rr��/� ��,,pp7� Aq•v 87-AL/ COL Warehouse #473020530 192 8" RESTRAINER FORD SERIES 1350 EA 2 '7 3. l 54 COL Warehouse #473020531 OO. 193 12"RESTRAINER FORD SERIES 1350 EA 2 $�.?Jt� 1 &,Y , a Q D COL Warehouse #473020533 194 1" FEMALE COPPER THREAD X 3/4 FLAIR COPPER WITH COPPER GASKET. FORD EA 100 5-s3 JS�J•� CO2-43 OR EQUAL TO BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #473020534 199 2" IPS TRANSITION GASKET FOR M.J. COL Warehouse #473020539 EA 100I.q()1gt). CC 201 SADDLE CLAMP DFW 33S248 EA 40 3 �� 1.�0 COL Warehouse #473020541 202 12" PVC MEGALUGS EA 20 5,1• qq l Qgg.gO COL Warehouse #473020542 l 203 81N UNIFLANGE (OR E-Z FLANGE) ADAPTER NO. 1008 WITH 8 SET SCREWS AND EA 1 RUBBER GASKET.FORD UFA 200-C-8 ��•�) ��•gl COL Warehouse #473030002 204 61N UNIFLANGE (OR E-Z) FLANGE WITH 8 SET SCREWS AND RUBBER GASKET CUM EA 1 OD 6.90 PLUS OR MINUS .06. TO BE A JCM 305 CAST FLANGE ADAPTER FORD UFA 20006 OR APPROVED EQUAL. EQUAL TO BE APPROVED BY WATER DEPT ENGINEER. COL Warehouse #473030004 231 4 X 4 IN. STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA 1 � q 1 f.l, 7� 21-7, W COL Warehouse #473030083 232 6 X 4 IN. STAINLESS STEEL TAPPING SLEEVE FOR 6 IN. CAST IRON CLASS 150 PIPE. EA 12 •a� $ 3� 5�` COL Warehouse #473030084 Ori t - 233 6"X6" STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA $ N q COL Warehouse #473030085 234 81N X 41N STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON EA 4 CLASS 150 PIPE. aaa•LID `'t • �Q� COL Warehouse #473030086 Q 235 81N X 61N STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA 7 3 �• 60 I-,�i,�.c'JO COL Warehouse #473030087 236 8IN X 81N STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON EA 2 CLASS 150 PIPE. �"�. `3 (� J4. al (� r Ol wnrnh^tico fte7zn!nnRR ITB #200-03/DC. Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 237 11OPE•X 41N STAINLESS STEEL TAPPING SLEEVE FOR 10 IN. CAST IRON CLASS 150 EA 1 ; L f q. qtg ajTn•q� COL Warehouse #473030089 238 101N X 61N STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS. 150 PIPE. EA 1 5'Cq 0'7 COL Warehouse #473030090 239 101N X SIN STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA 1 3� �• �3 3 ��✓ COL Warehouse #473030091 240 121N X 41N STAINLESS STEEL TAPPING SLEEVE FOR 12 IN. CAST IRON CLASS 150 EA 1 PIPE. 1 COL Warehouse 473030092 241 121N X 61N STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA 2 �� �.10 01 COL Warehouse #473030093 242 12"X8" STAINLESS STEEL TAPPING SLEEVE FOR CAST IRON CLASS 150 PIPE. EA 1 335-07 335•0-7 COL Warehouse #473030094 243 61N X 41N STAINLESS STEEL TAPPING SLEEVE FOR 6 IN. CLASS 150 ROUGH ASBESTOS EA 2 CEMENT. ��,�•�� ��• %�'' COL Warehouse #473030098 244 61N X 61N STAINLESS STEEL TAPPING SLEEVE FOR 6 IN. CLASS 150 ROUGH ASBESTOS EA 1 CEMENT. ,�i a I, . Owl �L l l COL Warehouse #473030099 245 8"X4" STAINLESS STEEL TAPPING SLEEVE FOR 8" ROUGH BARREL AC CLASS 150 PIPE. EA 2 3a L�(� Lt COL Warehouse #473030100 •�(� •� 246 BIN X 61N STAINLESS STEEL TAPPING SLEEVE FOR 8 IN. CLASS 150 ROUGH ASBESTOS EA 2 CEMENT. QJn' 3. � `i Li $ � • OD COL Warehouse #473030101 247 8"X8" STAINLESS STEEL TAPPING SLEEVE FOR 8" ROUGH BARREL CLASS 150 AC PIPE. EA 1�� 2J ��,�- COL Warehouse #473030102 125 248 101N X 61N STAINLESS STEEL TAPPING SLEEVE FOR 10 IN. CLASS 150 ROUGH ASBESTOS CEMENT. EA 2 a.�� 5 �. COL Warehouse #473030104 200-03/DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 249 101N X 81N STAINLESS STEEL TAPPING SLEEVE FOR 10 IN. CLASS 150 ROUGH EA 2 311>03 Waa• oc� ASBESTOS CEMENT. COL Warehouse #473030105 250 121N X 41N STAINLESS STEEL TAPPING SLEEVE FOR 12 IN. CLASS 150 ROUGH EA 1 a (.� .$ �(,Q •$ ASBESTOS CEMENT. COL Warehouse #473030106 251 12"X6" STAINLESS STEEL TAPPING SLEEVE FOR 12" ROUGH BARREL AC PIPE. EA 1 MOD Al/A) COL Warehouse #473030107 252 121N X 81N STAINLESS STEEL.TAPPING SLEEVE FOR 12 IN. CLASS 150 ROUGH 1 �,�+ �.r✓•�7 ���� ASBESTOS CEMENT. COL Warehouse #473030108 253 4"X4" STAINLESS STEEL TAPPING SLEEVE FOR ROUGH BARREL AC CLASS 150 PIPE. EA 2 �? • `T'� . / �•4Q COL Warehouse #473030111 264 31N FLANGED COUPLING ADAPTER OD RANGE 3.88-3.98 ROCKWELL NO. 912- EA 1 039603-000 OR APPROVED EQUAL �I •/�3 ���, 4�J COL Warehouse #473030132 265 4 IN. E-Z FLANGE WITH 4 SET SCREWS Et EZ GASKET. EBBA 1004 FORD UFA 200-C-4 EA 2 OR APPROVED EQUAL l ? . d 9 36, o4 COL Warehouse #473030133 266 31N UNI OR E-Z FLANGE ADAPTER NO. 1003 WITH 4 SET SCREWS Et UNI-FLANGE EA 2 GASKET. EBBA , FORD UPA 2000, TO BE APPROVED BY WATER DEPT ENGINEER, J O COL Warehouse #473030134 200-03/DCAddend.doc ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 27i 3/4 IN. CURB STOP: 3/4 IN. FULL PORT BALL VALVE, FIP X FIP, BRASS, AWWA C- EA 340 13 DD9-� 05a 800 SPECIFICATION, 360 DEGREE TURN WITH LOCK WINGS. WATER TIGHT BOTH ) , DIRECTIONS, FLUROCARBON COATED BALL; TOP MUST HAVE BLOW OUT PROOF STEM DESIGN. MUELLER NO. B-20200-3, HAYS NO.4300 WR, FORD NO. B-11-333 WR, JONES NO. J-1900 W LESS STOP, MC DONALD NO. 6111 W , APPROVED EQUAL. CURBSTOP MUST BE CAPABLE OF BEING LOCKED WITH A REGULAR PAD LOCK AND THE "F" SERIES BROOKS BARREL LOCK EQUAL TO BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #482020004 278 N. CURB STOP; I IN. FULL 0RT BALL VALVE, FIP X COPPER 2,200 a?� Q7 5a, �3�•0� AWWA C 800 PECIFICATIONS,360 DEGREE TURN WITH WINGS, WATER TIGHT BOTH DIRECTIONS, FLUROCARBON COATED BALL, TOP MUST HAVE BLOW OUT PROOF STEM DESIGN. MUELLER NO. B-25166-3, HAYS NO.4302-WR, FORD NO. B-21- 444-WR, JONES NO. J-1901 W LESS STOP, MC DONALD #6112W OR APPROVED EQUAL.CURBSTOP MUST BE CAPABLE OF BEING LOCKED WITH A REGULAR PAD LOCK AND THE "F" SERIES BROOKS BARREL LOCK. EQUAL TO BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #482020005 279 3/4 IN. CURB STOP; 3/4 IN. FULL PORT BALL VALVE, FIP X COPPER SERVICE PIPE, EA 70 17.26 A 207 BRASS AWWA C-800 SPECIFICATIONS, 360 DEGREE TURN WITH LOCKWINGS, WATER .,050 TIGHT BOTH DIRECTIONS; FLUROCARBON COATED BALL, TOP MUST HAVE BLOW OUT PROOF STEM DESIGN. MUELLER NO. B-25166-3, HAYS NO.4302-WR, JONES NO.J-1901W LESS STOP, MC DONALD NO. 6102 W LESS CHECK, FORD NO. B-21-333- WR OR EQUAL TO BE APPROVED BY PAUL NOLEN AT WATER UTILITIES. COL Warehouse #482020006 280 1 INCH CURB STOP; 1 IN. FULL PORT BALL VALVE, FIP X FIP BRASS, AWWA C-800 EA 60 n36 C`''� �T� '�� SPECIFICATION, 360 DEGREE TURN WITH LOCKWINGS, WATER TIGHT BOTH DIRECTIONS; FLUROCARBON COATED BALL. TOP MUST HAVE BLOW OUT PROOF STEM DESIGN. MUELLER NO.B-20200-3, HAYS NO. 4300-WR, FORD NO.B-11-444WR, JONES NO. J-1900 W LESS STOP, MC DONALD NO.6111 OR APPROVED EQUAL.CURBSTOP MUST BE CAPABLE OF BEING LOCKED WITH A REGULAR PAD LOCK AND THE "F" SERIES BROOKS BARREL LOCK EQUAL TO BE APPROVED BY PAUL Id AI CM AT \A/ATCD i rim ITICC rf%l 0A0•fA•fAAA9 ITB #200-03/DC, Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 295 GATE VALVE, 3 IN. MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 6 l 96 .,7A �� 174,3p- MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA- C500, MUELLER, M & H, DARLING OR CLOW. DD OR RS. WITH ACCESSORIES CONSISTING OF 8 T-HEAD BOLTS 5/8 X 3 WITH NUTS, TWO 3" M.J. GLANDS AND TWO 3" M.J. RUBBERS TO BE PACKAGED SEPARATELY WITH EACH ITEM. AMERICAN AVK COMPANY TYLER DRS 250 RESILIENT SEAT GATE VALVES OR APPROVED EQUAL. COL Warehouse #482030031 296 GATE VALVE, 4 IN., MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 25 ��,. 37 MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT, OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA-0500, MUELLER, M & H, DARLING, CLOW AMERICAN AVK COMPANY, TYLER DRS 250, OR APPROVED EQUAL. TO BE SHIPPED WITH ACCESSORIES CONSISTING OF 8 THEAD BOLTS 3/4 X 3 1 /2 WITH NUTS, TWO 4" GLANDS, AND TWO 4" M.J. RUBBERS TOBE PACKAGED SEPERATELY WITH EACH ITEM. COL Warehouse #482030032 297 GATE VALVE, 6 IN., MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 70�? ,p, ,I'Tad� 7 MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT, OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA-0500, MUELLER, M & H , DARLING OR CLOW. DD OR RS. TO INCLUDE 12 TEE -HEAD BOLTS 3/4 X 3 1 /2 WITH NUTS, TWO 6" M.J. GLANDS AND TWO 6" M.J. RUBBERS TO BE PACKAGED SEPERATELY WITH EACH ITEM.AMERICAN AVK COMPANY, TYLER DRS 250 RESILIENT SEAT GATE VALVES OR APPROVED EQUAL. COL Warehouse #482030033 298 GATE VALVE, 8 IN., MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 40 � it 7� J7 7 7� �.C7(] MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT, OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA-0500, MUELLER, M 6t H, DARLING OR CLOW. DD OD RS.WITH ACCESSORIES CONSISTING OF 12 TEE HEAD BOLTS 3/4 X 4 WITH NUTS, TWO 8" M.J. GLANDS AND TWO M.J. RUBBERS TO BE PACKAGED SEPERATELY WITH EACH ITEM. AMERCIAN AVK COMPANY, TYLER DRS 250 REILIENT SEAT GATE VALVES. AVK- 25-200-00 MJ X MJ-8" OR APPROVED EQUAL. COL Warehouse #482030034 200-03/DCAddend.doc ITS #200-03/DC. Addendum #1 Item # Description U/M Estimated Unit Price Extended Price Annual Usage 299 GATE VALVE, 10 IN., MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 7 & 75',qO � 7�-7 g� ` , MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT, OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA- C500, MUELLER, M Tt H , DARLING OR CLOW. DD OR RS WITH ACCESSORIES CONSISTING OF 16 T-HEAD BOLTS 3/4 X 4 WITH NUTS, TWO 10" M.J. GLANDS AND TWO 10" M.J. RUBBER TO BE PACKAGED SEPERATELY WITH EACH ITEM. AMERCIAN AVKCOMPANY, TYLER DRS 250 REILIENT SEAT GATE VALVES OR APPROVED EQUAL. COL Warehouse #482030035 300 GATE VALVE, 12 IN., MECHANICAL JOINT CAST OR DUCTILE IRON BODY, BRONZE EA 7 O T MOUNTED, NON -RISING STEM, 2 IN. OPERATING NUT, OPEN TO LEFT (COUNTER- CLOCKWISE) AWWA-0500, MUELLER, M e H, DARLING OR CLOW. DD OR RS. WITH ACCESSORIES CONSISTING OF 16 T-HEAD BOLTS 3/4 X 4 WITH NUTS, TWO 12" M.J. GLANDS AND TWO 12" M.J. RUBBER TO BE PACKAGED SEPERATELY WITH EACH ITEM. AMERCIAN AVK COMPANY, TYLER DRS 250 REILIENT SEAT GATE VALVES OR APPROVED EQUAL. COL Warehouse #482030036 TAPPING VALVE, 4 IN. MJ, CAST OR DUCTILE IRON BODY, BRONZE MOUNTED, NON - 301 EA 35 RISING STEM, 2" OPERATING NUT, OPEN TO LEFT (COUNTER -CLOCKWISE) AWWA- C500, MUELLER, MftH, DARLING OR CLOW. DD OR RS W/ FULL OPENING ACCESSORIES CONSISTING OF 8 BOLTS 5/8 X 3 WITH NUTS, AND 1 FLANGED END GASKET ON THE TAPPING SIDE. THE M.J. SIDE SHOULD HAVE 4 TEE -HEAD BOLTS 3/4 X 3-1/2 WITH NUTS, ONE 4" M.J. GLAND AND ONE 4" M.J. RUBBER. ALL ACCESSORIES ARE TO BE PACKAGED SEPERATELY WITH EACH ITEM. I.D. OF VALVE MUST BE AT LEAST 4". AMERICAN AVK COMPANY IS ALSO APPROVED TYLER DRS 250 REILIENT SEAT GATE VALVES IS ALSO APPROVED MUELLER T236016,MEtH 4751-01 COL Warehouse #482030037 j 302 TAPPING VALVE,6 IN. MJ, CAST OR DUCTILE IRON BODY, BRONZE MOUNTED,. NOW EA 32 RISING STEM, 2" OPERATING NUT, OPEN TO LEFT (COUNTER -CLOCKWISE) AWWA- 0500, MUELLER, MttH, DARLING OR CLOW. DD OR RS WITH ACCESSORIES CON- SISTING OF 8 BOLTS 3/4 X 3 WITH NUTS, AND ONE 6" FLANGED END GASKET ON THE TAPPING SIDE.THE ACCESSORIES ON THE MJ SIDE SHOULD INCLUDE 6 T- HEAD BOLTS 3/4 X 3 1 /2 WITH NUTS, ONE 6" M.J. GLAND AND ONE 6" M.J. RUBBER. ALL ACCESSORIES ARE TO BE PACKAGED SEPERATELY WITH EACH ITEM. AMERICAN AVK COMPANY, TYLER DRS 250 RESILIENT SEAT GATE VALVE OR APPROVED EQUAL. 1 COL Warehouse #482030038 ti C 200-03/DCAddend.doc ITB #200-03/DC, Addendum #2 Item # Description U/M Estimated Unit Price Extended Price Annual Usa e 303 TAPPING VALVE,8 IN MJ, CAST OR DUCTILE IRON BODY, BRONZE MOUNTED, NOW EA 15 rj5� • SIv �i - �� RISING STEM, 2-OPERATING NUT, OPEN TO LEFT (COUNTER -CLOCKWISE) AWWA C500, MUELLER, M&H, DARLING OR CLOW. DD OR RS W/FULL OPENING TAPPING SIDE TO INCLUDE 8 NUTS AND 8 BOLTS 3/4 X 3-1/2, AND 1 FLANGED END GASKET. M.J. SIDE TO INCLUDE 6 TEE -HEAD BOLTS 3/4 X 4 AND 6 NUTS, 1 M.J. RUBBER, AND 1 M.J. GLAND. ALL ACCESSORIES ARE TO BE PACKAGED SEPERATELY WITH EACH ITEM. AMERICAN AVK COMPANY, TYLER DRS 250 RESILIENT SEAT GATE VALVES MUELLER OR APPROVED EQUAL COL Warehouse #482030039 304 TAPPING VALVE, 10 IN. MJ, CAST OR DUCTILE IRON BODY, BRONZE MOUNTED, EA 1 g3a.3S g3a -'� NON -RISING STEM, 2" OPERATING NUT, OPEN TO LEFT (COUNTER -CLOCKWISE) AWWA-0500, MUELLER, M&H, DARLING OR CLOW. DO OR RS. WITH ACCESSORIES CONSISTING OF 12 BOLTS 7/8 X 3 1-1/2 WITH NUTS AND ONE 10" FLANGED END GASKET ON THE TAPPING SIDE. THE ACCESSORIES ON THE M.J. SIDE SHOULD BE 8 T-HEAD BOLTS 3/4 X 4 WITH NUTS, ONE 10" M.J. GLAND AND ONE 10" M.J. RUBBER. ALL ACCESSORIES SHOULD BE PACKAGED SEPERATELY WITH EACH ITEM. COL Warehouse #482030040 305 121N. MECHANICAL JOINT TAPPING VALVE. MUELLER NO. H-667 OR APPROVED EA 2 EQUAL. TO BE ORDERED WITH SLEEVES. GATE VALVE MAY BE EITHER DO OR RS. AMERICAN AVK COMPANY IS ALSO APPROVED TYLER DRS 250 REILIENT SEAT GATE VALVES IS ALSO APPROVED TO BE SHIPPED WITH ACCESSORIES CONSISTING OF 12 BOLTS 7/8 X 3 1 /2 WITH NUTS AND 1 FLANGED END GASKET ON THE TAPPING SIDE. THE MJ SIDE SHOULD HAVE 8 TEE -HEAD BOLTS 3/4 X 4 WITH NUTS AND 1-12" MJ GLAND AND 1-12" MJ RUBBER. ALL ACCESSORIES ARE TO BE PACKAGED SEPERATELY WITH EACH ITEM. COL Warehouse #482030041 306 FIRE HYDRANT OPERATING WRENCH.MUELLER NO A-311 FIRE HYDRANT EA 15 15 WRENCH....... LARGE END IS 2 15/16" FLAT TO FLAT CTAGON AND SMALL END IS 1 1 /21N. POINT TO FLAT PENTAGON. ALSO REFERRED TO AS A HOLD DOWN NUT WRENCH OR AN OPERATING AND DISASSEMBLY WRENCH. DOMESTIC ONLY. COL Warehouse #512010063 -PRICE: F.O.B. City of Lubbock "Days After Receipt of Order (ARO) i h 200-03/DCAddend2.doc PAYMENT TERMS AND DISCOUNTS - Bidder offers a prompt payment discount of _0 _%, net calendar days. Discounts will not be considered In determining low bid. Unless otherwise indicated on the Bid Form, payment terms will be NET THIRTY DAYS. The City will pay the successful bidder within thirty days after the receipt of a correct Invoice or after the date of acceptance, whichever event occurs later. Discounts for prompt payment requiring payment by the City within a stipulated number of days will be interpreted as applying within the stipulated number of calendar days after the date of receipt by the City of a correct Invoke or after the date of acceptance that meets contract requirements, whichever event occurs later. Discounts for payment In less than ten days will not be considered. INTERLOCAL PURCHASING (optfonoi): The City desires to make available to other local governmental entities of the State of Texas, by mutual agreement with the successful bidder, and properly authorized interlocal purchasing agreements as provided for by the Interlocal Cooperation Act (Chapter 791, Government Code), the right to purchase the same services, at the prices quoted, for the period of this contract. Each bidder shall indicate on the Bid Form in the space provided below if he/she will honor Political Subdivision orders in addition to orders from the City of Lubbock. Should these other governmental entities decide to participate in this contract, would you (the bidder) agree that all terms, conditions, specifications, and pricing would apply? Other governmental entities that might have interests In this contract are Frenship Independent School District, Lubbock Housing Authority, Lubbock County. Lubbock County Hospital District, Lubbock Independent School District, South Plains Association of Governments, City of Texarkana, Texas Tech University, West Texas.Munklpal Power Agency, Lynn County, and City of Wolff�o/rth. YES • NO /l • If you (the bidder) checked YES, the following will apply: Governmental entitle$. utilizing Interlocal Agreements for Cooperative Purchasing with the City of Lubbock will be eligible, but not obligated, to purchase materials/services under the contract(s) awarded as a result of this solicitation. All purchases by governmental entities other than the City of Lubbock will be billed directly to that governmental entity and paid by that governmental entity. City of Lubbock will not be responsible for another governmental entity's debts. Each governmental entity will order their own materials/service as needed. 200-03/DCAddend.doc ITB #200-03/DC, Addendum fit THIS BID IS SUBMITTED BA/ej� �104ratlon organized under the laws of the State of 4 S , or a partnership consisting Of or an individual trading as of the City of � u D 1 o E Address:_ _ i% _ , / A i n/ e-- City:_ �L , j b b as. lc, State: ^ Zip 7 f 41 l S— M/WBE Finn: LLI Woman I I Black American I I Native American ) Other Authbrized Representative - must sign by hand Officer Name and Title: /� i An C 4 r. i 'r , Please Print Business Telephone Number 8 0 G - 7 t'r " Q-f / / FAX: 80G - 7 6 S— - 70 70 FOR MY USE ONLY Bid Form Item Number(s) Awarded to Above Named Firm/individual: Date of Award by City Council (for bids over S25,000): Date P.O. /Contract Issued: Cl ,3nn_nmr)f'AA .na a—