HomeMy WebLinkAboutResolution - 2477 - Certificate Of Substantial Completeon-Lee Lewis-Terminal Building Phase II, LIA - 12_11_1986Resolution #2477 December 11. 1986 Agenda Item #21 MH:dw RESOLUTION BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF LUBBOCK: THAT the Mayor of the City of Lubbock BE and is hereby authorized and directed to execute for and on behalf of the City of Lubbock, a Certificate of Substantial Completion for the Lubbock International Airport Building Phase II, attached herewith, which shall be spread upon the minutes of the Council and as spread upon the minutes of this Council shall constitute and be a part of this Resolution as if fully copied herein in detail Passed by the City Council this j-th day of December , 1986. B. C. MCMINN, MAYOR ATTEST: i�Aette Boyd, City Secretary APPROVED AS TO CONTENT: Marvin Coffee, 15W&tor of Aviation APPROVED AS TO FORM: Michele Hart, Assistant City Attorney CERTIFICATE OF SUBSTANTIAL COMPLETION AIA DOCUMENT C704 Distribution to: OWNER ❑ ARCHITECT ❑ CONTRACTOR ❑ FIELD ❑ OTHER ❑ PROJECT: Lubbock International Airport (name, address) Terminal Building - Phase II Lubbock, Texas TO (Owner) : F City of Lubbock Lubbock, Texas ARCHITECT: Whitaker McQueen Jones & Associates ARCHITECT'S PROJECT NUMBER: 82-07-01 CONTRACTOR: Lee Lewis General Contractor CONTRACT FOR: General Construction L I CONTRACT DATE: June 14, 1984 DATE OF ISSUANCE: October 15, 1986 — PROJECT OR DESIGNATED PORTION SHALL INCLUDE: Total Project The Work performed under this Contract has been reviewed and found to be substantially complete. The Date of Substantial Completion of the Project or portion thereof designated above is hereby established as September 10, 1986 which is also the date of commencement of applicable warranties required by the Contract Documents, except as stated below. DEFINITION OF DATE OF SUBSTANTIAL COMPLETION The Date of Substantial Completion of the Work or designated portion thereof is the Date certified by the Architect when construction is sufficiently complete, in accordance with the Contract Documents, so the Owner can occupy or utilize the Work or designated portion thereof for the use for which it is intended, as expressed in the Contract Documents. A list of items to be completed or corrected, prepared by the Contractor and verified and amended by the Architect, is attached hereto. The failure to include any items on such list does not alter the responsibility of the Contractor to complete all Work' in accordance with the Contract Documents. The date of commencement of warranties for items on the attached list will be the date of final payment unless otherwise agreed to in writing; ~� Whitaker McQueen Jones & Associates ARCHITECT The Contractor will complete or correct the Work on from the above Date of Substantial Completion. Lee Lewis General Contractor CONTRACTOR l 116 DA E i0) days DATE The Owner accepts the Work or designated portion thereof as substantially complete and will assume ful posse Sion thereof at : (tl e) on a&y) APPROVED AS TO C0NTENT: ;�,f� APPROVED AS TO FORM: ��npc 11, 1986 OWNER _( , BY MAYOR DATE The responsibilities of the Owner and the Contractor for security, maintenance, heat, utilities, damage to the Work and insurance shall be as follows: (Note —Owner's and Contractor's legal_and insurance counsel should determine and review insurance requirements and coverage; Contractor shall secure consent of surety company, if any.) Owner shall assume responsibility for security, maintenance, heat, utilities, damage to the work and insurance as of 12:01 A.M., September 11, 1986. AIA DOCUMENT G704 - CERTIFICATE OF SUBSTANTIAL COMPLETION - APRIL 1978 EDITION - AIA® © 1978 - THE AMERICAN INSTITUTE OF ARCHITECTS, 1735 NEW YORK AVE., N.W., WASHINGTON, D.C. 20006 G704 — 1978 August 7, 1986 LIAX - FINAL INSPECTION Bill Hoffman Don Reed Yancey Jones 1. SOUTH BAGGAGE TOILETS - MEN'S A. Clean lite fixture lenses B. Caulk at corners where tile grout is cracked 2. SOUTH BAGGAGE TOILET - WOMEN A. Same as 1/B B. Relocate misaligned tilet partitions C. Caulk above cover plate in lavatory space. 3. SOUTH BAGGAGE AREA A. Finish clean up, floor, walls, windows, etc. B. Fill in crack at beam and grille. Col Line 18 C. Patch and paint bulkhead [clg] at Col Line 18 D. Replace 2 stained ceiling tiles at Col Line 18. E. Caulk or cover shim space at window heads on landside F. Complete installation of vinyl base. 15.1/D G. Caulk at covers against exposed AGG surfaces. H. Clean trash etc. off horizontal chase at clearstory windows. I. Fill floor void at 18/B J. Clean exhaust black off glass block wall and point up hole in mortor. 18/17/B K. Caulk left side of firehose cabinet L. Replace ceiling tile near 16/B. M. Caulk at vinyl/glass head at glass wall. Right of 16/B N. Complete and clean elec. room. 0. Install cover plate near 15/C. 4. SOUTH BAGGAGE OFFICE A. Complete clean up B. Complete caulk at window sill C. Paint/caulk at door trim 5. ENTRY #4 A. Secure loose bricks and point up mortor at each side of area where auto. doors were removed. [ledge brick] B. Improve hole patch on exposed AGG wall. [near 15/C] C. Align ceiling grid at west wall near auto exit door. [ I a n d s i d e ] D. Tooth in floor brick at new exp. AGG wall. [West side] 6. GATE #9 AREA A. Complete cleanup - brick ledge, windows and frames, horizontal chase, carpet, etc. 1 B. Tighten all thresh, plate screws at Boarding Bridge. C. Clean over spray off near ceiling at Eastend of stairwell. [West end also] D. Clean light fixture reflectors. E. Paint exposed steel angle near Boarding Bridge Entrance. F. Fill in gaps at R/A grille G. Clean Col. 18.7/B [Drywall mud] 7. BAY 17/18 BOARDING LOUNGE A. Same as 6A B. Adjacent Bay — finish and clean drinking fountain. C. Install clock at Col 18/B D. Caulk vinyl/glass joint around glass wall. E. Touch—up paint roof drain chase F. Same as 6/D 8. BAY 16/17 BOARDING LOUNGE A. Same as 6A B. Same as 6D C. Same as 7D D. Caulk around Firehose Cabinet. E. Clean Firehose Cabinet. 9. BAY 15/16 [GATE #81 BOARDING LOUNGE A. Same as 6A B. Same as 6D C. Same as 7D D. Clean ceiling members [low roof] affected by temporary contruction partition. E. Repair N/W brick ledge. F. Caulk west PC sill members. G. Replace stained carpet along Col Line A. H. Align and install existing light fixture line. I. Complete installation of floor grilles. *J. Point up holes in mortor at glass block walls. K. Fill void at vinyl/exp. AGG joint over glass block wall. 10. BAY 14/15 — BOARDING LOUNGE A. Col. 15/A, repair cracked roof member area near col. B. Same as 9D — high and low roof members. C. Paint black reveal at bulkhead. D. Patch plaster hole at upper SW corner at Col 15/B. 11. WOMEN'S RESTROOM BAY 14/15 A. Adjust access panel lock. B. Caulk gap below and above napkin accessories. C. Recaulk around Handicap lavatory at wall D. Caulk around flush plate in stall #2. *E. Replace ceiling tile and clean up elec. rooms. F. Same as 1B 12. MEN'S RESTROOM- BAY 14/15 A. Caulk at flush plate at 3rd urinal. B. Complete installation of toilet partitions. C. Install floor drain cover D. Complete tile work below access door. E. Complete cleaning of total area. 0) F. Same as 1B. 13. AREA 11/14 C/D7 [TICKETING LOUNGE] A. Complete fire alarm installation Col. 14/D. B. Trim at vinyl/precast joint also clean off old caulk. C. Clean new brick floors, tar and surface mortor. D. Finish clean-up, windows, brick sill frames, etc. E. Replace irregular brick areas along expansion joint. Approx. 5 areas. F. Adjust linear grille G. Complete trim at east end of drapery pocket. H. Clean off East PC panel I. Repair trim at bulkhead and beam joint at Col. Line 14. J. Clean angle trim at bulkhead and complete painting at east end. 14. AREA 11/14 B/C NEW TICKETING AREA A. Clean-up area - leave temporary coverings over con- veyor openings. B. Replace missing ceiling tile. C. Install door closer cover on west door. 15. ENTRY RAMP AND AREA #3 A. Secure side ledge brick at top of ramp [west] 16. SCREENING AREA #2 A. Replace missing ceiling tile. B. Secure sliding door track. C. Clean cement dust off AGG, wall [east area] D. Rework east wall [elec. clos] to match west wall exp. AGG. E. Complete work and clean up elec. closet. 17. GRID 8/9 "BAR" AREA A. Same as 9/1) B. Same as 9/H C. Install missing ceiling tile. D. Complete installation of floor grilles. *E. Complete carpet installation. *F. Complete installation of VWC. *G. Install vinyl base. H. Clean PC panels each side I. Repair water damage at bulkhead. J. Align and tighten wood rail. K. Complete clean-up of brick ledge, windows and frames. *Items with asterisk hold for credit. 18. ELEVATOR/STAIR AREA A. Clean and touch-up exterior of elevator shaft includ- ing door and frame. [conduct trial touch-up]. B. Clean lite reflectors under landing. C. Secure carpet at first raiser. D. Paint reveal at wood/exp. AGG line on stringer flat black. E. Clean lite fixtures on elevator shaft. F. Remove dark paint from handrail. G. Pull outside stringer trim back in line. 3 H. Complete gasket installation at upper window and complete clean—up of windows and frames. I. Clean stairs and handrail. J. Complete patch and paint at roof channels. K. Complete upper window trim at beam. L. Complete plaster trim at head of stair. [outside stringer] 19. RENT CAR LOBBY A. Clean floor near wood wall B. Align and level linear floor grille. C. Neatly grout or replace spalled brick. D. Same as 9/D E. Trim out channel support plates. F. Stain finish panel trim at Security Office. 20. ENTRY RAMP #2 A.Secure brick each side at top of ramp. 21. EAST TICKETING FOYER A. Complete painting of drapery pocket. B. Complete cleaning of window frames. 22. BAY 1/2 [NEW GATE #31 A. Same as 9/D [temp. wall] B. Clean off chanel legs at old window wall. [caulking] paint as required. C. Caulk at jambs and head of glass block wall at vinyl. D. Clean floor grilles. E. Clean the dirty lite reflector. F. Install connection covers where possible. G. Complete clean—up. H. Caulk PC sill joints at N/E corner. I. Secure loose brick and caulk expansion joint at 1/A. J. Touch up paint bottom of channel leg at horizontal chase. 23. BAY 0/1 BOARDING LOUNGE A. Complete clean—up. B. Correct trim/caulk at upper right north window. C. Same as 22/C. D. Straighten caulking line on large windows. 24. BAY 101/0 A. Complete cleaning of brick sill, linear grilles window frames, etc. *B. Clean off lens of large ceiling lites. LIAX FINAL INSPECTION CONTINUED September 3, 1986 25. BAY 0/101 — Clean caulking off south ledge. 26. COL B/101 — Complete elec. items. 4 27. COL. A/101 - Fill behind cover plate. *28.Complete window and frame cleaning. *29.Clean light fixture enclosures at north horizontal chase 30. BAY 101/102 A. Caulk at upper SW corner B. Tighten wood rail support bracket C. Provide transition strip at exit door sill D. Adjust exit door. *31.Activate all alarmed exit hardware. *32.Complete final cleanup *33.Clean construction debris off floor grilles/registers 34. COL B/104 - Fill in around conv. outlet. 35. BOARDING GATE AREAS NO. 2 - BAY 104/105 A. Patch PC conc. at floor [2 places] and at ceiling above EXIT sign. B. Complete installation of telephone. C. Adjust door holder at jetway door. D. Tighten threshold at jetway E. Clean mortor, caulk, etc. off PC panel [west] F. Clean dark caulk off brick ledge. G. Clean brick stairs and landing. H. Touch-up paint at gate hinge. I. Rework and patch floor grille opening. 36. BETWEEN A & Al AT 105 - Touch up at leak area on PC channel. A. Touch-up paint at caulk joints this area at beam. 37. BAY 105/106 A. Finish base at brick ledge *B. Clean-up jamb caulking at upper window units. C. Secure rubber glazing gasket at southeast corner. 38. Col. Line 106 - Al/A Clean-up water stain on ceiling structure. *39.Tighten all loose rail sections. [wood hand rail] 40. BAY 106/107 A. Clean stains off south ledge B. Complete base at brick ledge C. Col. Line 107 - touch up water stain and channel end at beam. D. Touch-up scratches on vertical mills - north windows 41. BAY 107/108 A. Fill gap above black reveal on south wall. B. Clean brick stairs/landing C. Clean spots off precast. D. Secure carpet at elec. floor outlets. E. Adjust door [Jetway] closer and alignment. 5 UPPER LEVEL 1. COMPLETE ELEC. A. Bay 9/10 - install panel covers, outlet covers, com- plete demo and termination of existing telephone equipment lines, etc. B. Touch-up paint after this work. C. Improve trim above East door. D. Trim out reversed door frames on south wall. E. Install all missing or burned out bulbs. F. Install transition piece to trim out linear floor grille. G. Install thermostat covers. H. Clean chalk off Col. B/9 2. BAY 8/9 A. Complete caulk at window frame and beam. NW corner. B. Install cap at floor grille [west] and transition trim [east] C. Patch and touch-up PC panels [at lifting eyes, etc.] D. Turn all ceiling tile correctly. E. Clean lite cans. F. Clean existing caulking off Cols. and beams. G. Clean off battery stain [alarmed exit door, also adjust closer] H. Adjust East door. I. Women's Toilet - Secure door stile at first stall. J. Caulk around flusher plate in first stall. K. Adjust grille over back stall. 3. MEN'S TOILET AREA A. Elevator Foyer - clean off base adhesive at elev. door jambs. B. Caulk wall tile near flush valve. C. Secure flushing apparatus at toilet stall. D. Adjust ceiling grille over urinal. E. Caulk above lite switch. 4. BAY 7/8 A. Install all ceiling tile consistently. B. Replace all missing or burned out bulbs. 5. ELEVATOR - Needs to be prepared for inspection. APRON LEVEL 1. STAIR NO. 5 [6A STAIR] A. At upper landing caulk CMU joint upper N/E corner. B. Replace all damaged, stained, missing ceiling tile. C. Clean lite fixture lens! D. Caulk PC joints at lower landing area. E. Turn keying over on north door. A 2. STORAGE ROOM - GATE 9 A. Clean out storage room. B. Complete elec. work. 3. GATE STAIR NO. 9 A. Complete cleanup B. Clean all stains off brick stairs and landing. C. Complete caulking under stair and paint. D. Clean up PC panel at landing. 4. BAGGAGE HANDLING NO. 2 [WEST] A. Remove plywood forms from above. B. Leaks in overhead lines? C. Seal conc. floors. D. Remove temporary power line? at B/16 E. Replace emergency release on center door. F. Replace broken lites in 0/4 doors. G. Complete painting of OH doors [edges] and trim. 5. TELEPHONE PANEL ROOM A. Complete clean-up. 6. COMMUNICATION EQUIPMENT ROOM A. Complete common work and clean-up. 7. OLD EMER. GEN. ROOM A. Patch CMU walls at Mech. penetrations. 8. OLD SOUTHWEST OFFICES A. Caulk around gaps at cover plates B. Replace damaged ceiling the C. Complete clean-up. *9. PAINT PATCHES at Mech penetration if walls were origin- ally painted. 10. BAGGAGE HANDLING NO. 1 [EAST] A. Seal above south west door. 11. APRON STORAGE AT GATE 1 A. Grout joints in CMU. 12. BOARDING STAIR NO. 1 A. Clean lite fixture B. Replace ceiling tile C. Caulk at stair/stringer and wall 13. BOARDING STAIR STORAGE NO. 2 A. Clean out storage room. 14. BOARDING STAIR #2 A. Caulk joint in floor at door [also at stair #11. 15. EMERGENCY STAIR AT BAGGAGE CALIM #1 [EAST] A. Paint handrail B. Clean up construction debris. *16.General Note - either seal mech. penetrations with wall material or cover with escutcheons. 7 17. Replace ceiling in American Airlines engine repair shop. EXTERIOR - APRONSIDE 1. COMPLETE CLEAN-UP OF GROUNDS A. Around cooling tower B. At south construction entrance and stack areas in- side and outside fence. C. Reshape south ditch to drain and regrade south slope to drain. 2. COOLING TOWER - PAINT EXPOSED ELEC. CONDUIT AND BOXES A. Clean-up pump room. B. Caulk around pumproom door. 3. South Exterior [End] Upper left corner - clean black off PC. 4. Paint metal trim at plaster soffit at Col. Line 16 thru 19. 5. Caulk hole at bottom panel adjoining stairwell #9. *6. Paint access doors. *7. Caulk around personnel doors [inside and out] 8. Back side of Boarding Gate No. 8 - clean off elec. burn on PC. 9. Boarding Stair #9 - Clean off plaster on PC [East Side] 10. Touch up paint at OH door caulking. 11. Repair water damaged area at plaster soffit between Col Line 8 and 9 12. Col 9/Al - Clean conc. off existing Col. 13. Caulk and paint at soffit plaster bead - Col. Line 8/9 *14.Caulk around soffit lights. 15. Col. A/2 - Paint exposed conc. due to construction drilling. 16. Repair water damaged soffit at Col. Lines 1/2 17. Complete soffit para at Col. Line 1/2. 18. Cover gap at soffit reveal at Col. Line 1 19. Install missing plug at soffit [damper control] between Col. Lines 0/1. 20. Caulk or repair hole in bottom of P/C spandrel. [Col. Lines 0/11 21. Cover gap at plaster soffit reveal at Col. Line 104 22. Repair cracked soffit area near Item 21. 23. Recaulk west vert. MULL at stair windows [Boarding Stair #2] *24. General Note — set all door hinge pins. 25. Bay 105/106 — Remove anchor bolts in apron near wall. 26. Paint trim strip at upper spandrel Col. Line 106. LIAR Exterior — Cont'd LANDSIDE 27. Clean east screenwall PC panel. 28. Secure soffit reveal — SE corner 29. Col B/107 — Fill void below PC spandrel. 30. Caulk hole at PC at Col B/106 [2nd spandrel panel] 31. Caulk PC joint above louver [Col. Line 105/106] 32. Caulk vertical joint at sides of louvers and Cols. B/105 and B/106 33. Clean overspray [cement or plaster] off metal panels. 34. Clean mortor off PC screen panel — Bay 103/104 35. Fill in behind new approach curbing Bay 102/103 36. Clean stains off upper spandrel panel Bay 102/103 37. Straighten fence fabric Bay 102/103 38. Complete cleanup of east end access and stack area. Complete fill and grade uniformly to drain. 39. Caulk around conv. outlet at back of Boarding Stair #1 and #2. 40. Adjust east OH door at shop to close top gap. 41. Clean stain off wall at fence posts. 42. Secure fence post at Col. C/101 43. Touch—up paint wall at Bay 0/101 E 44. Patch hole at bottom of spandrel panel near Col D/0 45. Caulk CMU wall joint at Col. Line 0 and 0.1 46. Complete painting of foundation wall at Col. Line 2 47. Remove temporary fence pole near Col. Line 2 48. Caulk and paint end of PC panel exposed at wall. Col. Line 2 49. Remove temporary stairs at mech. room door - Bay 2/3. 50. Caulk all joints showing daylight in transformer vault. 51. Install damper control plugs in soffit bays 9-12 52. Fill around soffit light fixtures 53. Fill gap at soffit reveal and Col. Line 18. LIAX FINAL INSPECTION LANDSIDE - EXTERIOR, Cont'd 1. Upper PC panel aabove D/18 and E/18 - clean off mortor stain. 2. Upper spandrel beam at Entry #4 - clean PC panels. 3. Clean loose aggregate off sill near Col. D/15. *4. Paint structural strap reinforcing. 5. Caulk gap at head trim over window in Bay 12/13 and hole in upper left at windows in Bay 11/12. 6. Caulk all joints of PC top to transformer vault. 7. Work earthfill evenly at top of transformer vault. 8. Repair damaged aggregate surface at large beam Col. Line 10. 9. Rework fill at landscape slopes to fill in around column depressions. 10. Clean mortor off lower spandrel panel at Bay 4/5. 11. Grade fill even at landscape area Bay 1/2. 12. Clean mortor stains of spandrel panel on Col. Line 2 over Entry #1. 13. Paint exposed structural connect at roof and Col. D/2. 10 x14.Replace missing connection covers. Note: A preleminary inspection of the roof area revealed incomplete and faulty work as follows: 1. Incomplete caulking 2. Incomplete and improper window installations. 3. Faulty areas relative to roof flashing. The above conditions were noted after inspecting approxi— mately 25 — 30% of the project's roof. Due to the number of items observed, the contractors representative was instruc— ted to remedy these conditions over the entire roof, after which the Final Inspection will continue. 11 LUBBOCK AIRPORT TERMINAL BUILDING ADDITION ELECTRICAL PUNCHLIST ITEMS Room 204 - 1. Light fixture lens is broken. 2. Lamps should be same color. Room 205 - Lamps should be same color. Roof - 1. One Lighting Protection air terminal is missing. Some rods are not securely attached. 2. Some bends of roof cable on the lighting system are too sharp. The minimum bending radius is eight (8) inches. Ticketing 133 - The noala microphone is not installed. Baggage Claim 105 - 1. Several fluorescent fixtures located above the baggage handlers are partially covered. These fixtures should be relocated to clear the equipment. 2. One HPS fixture near the southeast corner needs cleaning on interior. Electrical Room 106 - 1. The circuit directory inside Panel "LM-7" has the incorrect panel name. 2. Clean all unused electrical materials and trash from room. 3. Panel "ELM-3" needs a typewritten circuit directory. 4. Seal around all conduit floor and wall penetrations. 5. The heat detector needs relocating so as not to interfere with the light fixture. 6. The housing on one contactor needs a conduit knockout filler. 7. The ground connection for the dry -type transformer is not made. Make the connection and install a bonding jumper from the conduit to the ground electrode. Office 107 - Light fixture louvers need cleaning. Boarding Lounge 101 and Circulation 102 - 1. Several HPS fixtures need cleaning on the interior. 2. One fire alarm horn does not cover the wall opening. 3. One of the column - mounted receptacles needs a box extension and several of the receptacle plates do not adequately cover the wall opening. Circulation 127 - 1. Clock is not installed. 2. Light fixtures in adjacent restrooms need cleaning. Electrical Room 135 - 1. Panel "LM-8" needs nameplate. 2. One contactor housing needs a conduit knockout filler. 3. Panel "RM-6" needs typewritten circuit directory. 4. Patch all unused openings in floor. 5. Seal around all conduit penetrations. Toilets 139 & 140 - Clean light fixture lenses. Baggage Claim 137 - 1. Several fluorescent fixtures located above the baggage handlers are partially covered by the baggage handling equipment. These should be relocated to clear the equipment. 2. One of the telephone outlets should receive a blank coverplate if a phone is not installed at the location. 3. One HPS fixture.is not operating. 4. Several HPS fixtures need cleaning on the interior. Circulation 130 - Replace the northeast fluorescent fixture with a new fixture. Ticketing 129 - The lamps in parabolic fixtures should all be same color (warm white). Security 117 - 1. In fire alarm panel, each zone should be labeled on the face to identify each zone by building area description. 2. The control panel indicates a "trouble" condition. Locate and correct. 3. The engine/generator annunciator panel is not giving the proper status indications. 4. The red lamp annunciator above the fire alarm panel needs a label. Chiller Room - 1. One of the Honeywell boxes needs a cover. 2. Motor Control Center "MA-7" needs a partial front cover. Baggage Handling 015 - At the east conveyor, strap the conduit at the floor better. Mechanical 016 - 1. Additional conduit supports are needed at the air handling units. 2. At the transformer ground connection, bond the conduit to the grounding electrode. 3. The telephone outlet on exterior to Storage 017 has a plate which does not adequately cover the wall opening. Cooling Tower - 1. Label all disconnects. 2. The disconnect housing for the exhaust fan needs a conduit knockout filler. Mechanical 008 - Clean trash and unused materials from interior of automatic transfer switch. Mechanical 003 - 1. Panel "ELM-5" needs nameplate. 2. The receptacle on the east wall is broken. 3. Conduits at AHU #3 need additional supports. General Items - 1. Where circuits have been changed or added to existing panels, update the circuit directories to indicate the proper loads. 2. Several of the fluorescent lamps appear to have a phospher deterioration inside the lamps. Have the manufacturer's representative inspect the lamps for manufacturing defects and replace as necessary. 3. The installation of the sound system is incomplete. Complete the installation, provide the owner with the training specified and provide the documentation as specified on page 16750-8 of the Specifications. 4. Furnish the training and documentation to the owner as specified for the clock system. 5. For the fire alarm system, provide the owner with the training and documentation specified along with the state certification. Make the final adjustments necessary and demonstrate the system. 6. For the emergency generator, have the manufacturer's representative perform the final adjustments, demonstrate the proper operation of the system, provide the training for the owner, set the exercise clock, and provide the specified documentation. 7. Provide accurate "As -Built" drawings, manufacturer's guarantees and operating manuals as specified. LUBBOCK AIRPORT FINAL INSPECTION SEPTEMBER 3, 1986 1. Men's 205: Install a new seat on water closet, electrical rough -in for flush valve is the wrong location, lavatories are to have new faucets. 2. Women's 204: Install new seats on water closets, lavatories to have new faucets. 3. Roof: Repair rain cap on engine generator exhaust outlet. 4. Circulation 114: Replace floor grilles with bent bars. 5. Baggage Claim 103: Replace or straighten bent bars in floor grille. 6. Men's 103: Tighten gooseneck faucet on lavatories, install bolt caps on water closet. 7. Women's 104: Install bolt caps on water closets. 8. Men's 111: Install bolt caps on water closets. 9. Women's 109: Install bolt caps on water closets, electrical connection to new water closet needs repair work, washer under lavatory faucet lever is coming out. 10. Circulation 102: Clean all floor grilles, install handle on fire hose cabinet door. Clean fire hose cabinet. 11. Circulation 101: Clean all floor grilles, install handle on fire hose cabinet door. Repair bent bar on floor grille at northeast corner. 12. Concession Area 118: Install six floor grilles. 13. Men's 132: Repair wiring to water closet flush valve. 14. Women's 133: Automatic flush valve on west water closet does not operate, install bolt caps on water closets. 15. Circulation 134: Clean all floor grilles, reattach duct connection on several floor grilles along the east wall, there is no water to the electric water cooler. 16. Men's 140: Install bolt caps on water closets, automatic flush valve on one water closet does not work. 17. Baggage Claim 137: Clean fire hose cabinets, push bar on electric water cooler hangs open. 18. Women'.s 139: Install bolt caps on water closets. 19. Office 124: Install thermostat for existing multi -zone air unit. 20. Office 122: Install thermostat for existing multi -zone air unit. 21. Security Office: Install bolt caps on water closet. 22. Mechanical Room 003: The ammeter on the Honeywell panel does not work, vapor seal insulation at evaporator connections, the flow meters on the condenser water pump and condenser do not operate, install escutcheon on cold water pipes entering the room, complete the stenciling of the piping with flow direction arrows, vapor seal insulation at secondary chilled water pump connections and primary chilled water pump connections, extend drain from chilled water pump bases to drain. 23. Existing Boiler Room: Provide escutcheons on all domestic water pipe wall penetrations. 24. Apron Level along Column Line 12: The chilled water pipe insulation is torn and needs to be repaired. 25. Existing Mechanical Room 014: Replace duct insulation on outside air ductwork. 26. Apron Level on Grid Line 14: Hot water pipe connections to existing system have fittings that are uninsulated. 27. Apron Level along the north side of Column 14: The 4" chilled water supply return stub outs need to have the insulation vapor sealed. 28. Baggage 015: Vapor seal the chilled water piping insulation as it enters the north wall, vapor seal chilled water pipe insulation at the south wall, apply "Fire Hose" decal to fire hose cabinets. 29. Mechanical Room 016: Apply "Fire Hose" decal to fire hose cabinet, insure operation of all chilled water and heating water flow meters, remove 2X4 from between condensed water lines above fan section of Air Unit No. 5, vapor seal around gage cocks and thermometer wells at the air handling unit connections. Provide handle on Air Unit No. 4 fan section door. Provide vapor seal at all air handling unit connections, Air Unit No. 4 has a break in the seal at the bottom of the chilled water inlet connection. Provide tag at each flow measuring device. 30. Mechanical Room beneath the Cooling Tower: Install fan guard on vent fan, motor is burned out on vent fan, verify installation and operation of cooling tower sump heater and fan vibration switch. 31. Mechanical Room 008: Replace 1" fiberglass filters at generator intake lever with Farr 30/30 equivalent, at Air Unit No. 6 replace all -thread rod support at air handling unit filter box with spring isolator, vapor seal all insulation and finish raw edges of all insulation. 32. Mechanical Room 004: Apply "Fire Hose" decal to fire hose cabinet door, seal around duct penetrations of concrete wall. 33. Office 101 and Breakroom 102: Install thermostats on fan coil units to cycle fan, insulate drops to diffusers. 34. Work Area 104: Install filters in fan coil units. Vapor seal chilled water insulation at wall penetrations. Install pipe shields under heating water piping. 35. Mechanical Room 003: Install "Fire Hose" decal on fire hose cabinet, on Air Unit No. 1 vapor seal chilled water pipe connections, install handle on access door to coil compartment on Air Unit No. 2. Vapor seal all insulation. Flow measuring meters are not operating. 36. Exterior on the east end: The underground fire hydrant has not been installed. 37. General Notes: All supply air ductwork shall be sealed, clean all equipment, apply glass cloth jacket on all exposed pipe insulation, finish raw edges of all insulation, insulate and vapor seal all chilled water stub -out, submit "As Built" drawings, submit manufacturer's guarantees, submit operating manuals, submit Test and Balance Report, complete marking of pipe, tag all valves, instruct Owner's personnel in operations of systems including temperature controls and water treatment. Remove trash from behind all floor grilles. Balance hot water circulating lines to all toilets, clean all floor grilles. Provide finished ends to all piped insulation. Provide shields at all pipe hangers with insulation. Clean all grease from pipe and floor at mechanical joint couplings. Install a full size vent on AHU side of drain pan p-traps to allow drainage. 38. Odor Control Filters: Filters were not accessible during walk-thru. Contractor to provide access to each for inspection.