HomeMy WebLinkAboutResolution - 1393 - Contract-Cyclone Fence Sales-Fencing, LP&L Substation At Municipal Dr & Guava St - 05_12_1983RESOLUTION 1393 - 5/12/83 Bid 7349 jT DGV:cl RESOLUTION BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF LUBBOCK: THAT the Mayor of the City of Lubbock BE and is hereby authorized and directed to execute for and on behalf of the City of Lubbock a Contract with Cyclone Fence Sales for a substation fence, as per specification number SE0001- 9-033183, pursuant to Bid Number 7349, said contract to be entered into by and between said City as the prospective owner and Cyclone Fence Sales as the contractor for such construction. The stated amount for such contract is $8,260.00, attached herewith which shall be spread upon the minutes of the Council and as spread upon the minutes of this Council shall constitute and be a part of this Resolution as if fully copied herein in detail. Passed by the City Council this 12th day of M'I V 1983. _ v ALA HENRY , MAYOR 0 TEN1 ATTEST: E elyn Ga ga, City Secr ry-Treasurer APPROVED AS TO CONTENT: C Carroll McDonald, Director of Electric Utilities APPROVED AS TO FORM: Vandiv`ir, First Assistant City Attorney RESOLUTION 1393.- 5/12/83 CONTRACT AGREEMENT , 1 (EQUIPMENT) THIS AGREEMENT, made and entered into this 12th day of May 19 83 , by and between The City of Lubbock, Texas acting through its Mayor and City Council thereunto duly authorized so to do, Party of the First Part, and hereinafter called the Purchaser, and Cyclone Fence Sales a corporation of Texas , Party of the Second Part, and hereinafter called the Contractor. WITNESSETH: THAT WHEREAS, the Purchaser has caused to be prepared, in accordance with law, specifications, plans, and other contract documents for the work herein described, and has approved and adopted said documents, and has caused to be published, in the manner and for the time required by law, an advertisement for and in connection with acquiring Substation Fence in accordance with the terms of this Contract; and WHEREAS, the said Contractor, in response to such advertisement, has submitted to the Purchaser, in the manner and at the time specified, a sealed proposal in accordance with the terms of said advertisement; and WHEREAS, the Purchaser, in the manner prescribed by law, has publicly opened, examined, and canvassed the proposals submitted in response to the published invitation therefor, and as a result of such canvass has determined and declared the aforesaid Contractor to be the best bidder for the said work and has duly awarded to the said Contractor a contract therefor, for the sum or sums named in the Contractor's proposal, a copy thereof being attached to and made a part of this Contract. NOW THEREFORE, in consideration of the compensation to be paid to the Contractor and of the mutual agreements herein contained, the Parties to these presents have agreed and hereby agree, the Purchaser for itself and its successors, and the Contractor for itself, himself, or themselves, -or its, his, or their successors and assigns, or its, his, or their executors and administrators, as follows: ARTICLE I. That the Contractor shall (a) Furnish all materials,. supplies, and equipment specified and required to be incorporated in and form a permanent part of the completed work; (b) Provide and perform all necessary work; and, in a good, substantial, and workmanlike manner and in accordance with the provisions of the General Conditions, and the Instructions to Bidders, (which are attached hereto and made a part hereof) and in conformity with the Specifications Number SE-0001-9-033183 (c) Execute and complete all work included in and covered by the Purchaser's official award of this Contract to the said Contractor, such award being based on the acceptance by the Purchaser of the Contractor's proposal, or part thereof, as follows: Substation Fence l.r.� 1lLt 11. i }gat Lhe :: rc} user small pay to the Contractor for the performance of the work embraced in this Contract, and the Contractor will accept as full compensation therfor, the sum (subject to adjustment as pro- vided by the Contract) of _ Eight thousand two hundred sixty dollars ($ 8,260.00 ) for all work covered by and included in the Contract award and designated in the foregoing Article I. ARTICLE III.- The Contractor shall proceed with the work to be performed under the provisions of this Contract on, or within ten (10) days following, the date of public acceptance.of the Contractor's proposal by the Purchaser. Contractor shall not'delay the start of the work to be performed under the provisions of this Contract except by written order from the Purchaser. Contractor shall complete said work by July 1st, 1983 IN WITNESS WHEREOF, the Parties hereto have executed this Contract as of day and year first written. CITY OF LUBBOCK BY: x/r, �/✓ ATTEST: UMMMMM, 7 ALAN HENRY Evelyn Ga fga, City4S46c ary-Treasurer APPROVED AS TO CONTENT: APPROVED AS TO FORM: DONALD G. VANDIVER, Assistant':Clty:Attor ney PARTY OF THE SECOND PART (CONTRACTOR) ATTEST: Secretary BY: Signature of Officer Title NOTE: This Contract must be signed by the President or Vice President of the Contractor's firm and attested by the Secretary of the firm. If the Contract is to be signed by any person other than the President or Vice President, then a Board Resolution authorizing said person to sign and bind the firm must be included with each copy of the Contract. STANDARD CHAIN LINK FENCE SPECIFICATIONS I. STYLE FENCE Chain link fence with three strands of barbed wire on 450 extension arms. Fence to be nine (9) feet high overall when erec'fed. 11. FABRIC ' Steel wire to be ninety-six (96) inches high, #9 gauge woven in a two (2) inch mesh with barbed selvages top and bottom. The wire pickets shall stand a minimum tensile strength -of 80,000 PSI based on a cross sectional area of wire. 111. PROTECTIVE COATING The chain link fabric shall be either galvanized after weaving or aluminum coated. Galvanizing shall be 2 oz. per sq. ft. of area in accordance with ASTM A392 Class 11. Aluminum coating shall be .40 oz. per sq. ft. of area in accordance with ASTM A491-63-T. IV. BOTTOM TENSION WIRE E BARBED WIRE Steel barbed wire to be of 4 point pattern composed of two strands of 121 gauge line wires with 14 gauge barbs spaced on approximately five (5) inch centers. Bottom tension wire shall be No. 7 gauge spring coil tension wire, fastened to chain link fabric with No. 11 gauge hog rings on twenty-four (24) inch centers. Coating shall match coating of fabric furnished. V. TOP RAIL 1-5/8" OD Schedule 40 galvanized pipe, or 1-5/8" x 4" galvanized roll section. Fabric to be tied to top rail every 24" with #9 gauge aluminum tie wires. VI. BRACES Same material as top rail and trussed from line post back to terminal post with 3/8" galvanized rod complete with truss tightener. VII. LINE POSTS Galvanized Hi Carbon 1.875" H-Column or 2-3/8" OD Schedule 40 pipe, spaced on centers not to exceed ten (10) feet. Post equipped with #6 gauge gal- vanized clips on. fourteen (14) inch centers. -111. EXTENSION ARMS Line post extension arms to withstand a minimum pull down weight of 450 lbs. from end of arm and are to be made of pressed steel or malleable iron base - 1 - with pressed steel extension riveted and galvanized after assembly. IX. TERMINAL POSTS End, corner, and pull posts to be 2-7/8" OD Schedule 40 galvanized pipe, or 31" x 31" galvanized roll formed section. Fabric to be attached to terminal posts by use of T' x 3/4" tension bars laced to post every 14" with•11 gauge 1" wide steel bands and 3/8" diameter bolts and nuts, or by integrally weav- ing wire to post in formed lock loops. Pipe posts -to have cast iron or , pressed steel top of manufacturer's standard design. X. GATE POSTS Maximum opening 6' single or 12' double - 277/8" OD Schedule 40 galvanized pipe, or 31" x 31" galvanized roll section. Maximum opening 12' single or 24' double - 4" OD galvanized pipe weight 9.11#1 per ft. Maximum' opening 18' single or 36' double - 6-5/8" OD galvanized pipe weight 18.971 per ft. Over 18' single or 36' double - 8-5/8" OD galvanized pipe weight. XI. GATES Frame to be 2" OD galvanized pipe with pressed steel or malleable .iron corner ells riveted with 4 rivets per corner. Internal bracing shall be 1-3/8" OD pipe with 3/8" adjustable truss rods. Gate shall be complete with padlocking device, center rest and semi -automatic catch to secure drive gate in open position. XII. TOLERANCE Standard Mill Tolerances on all framework members and chainilink fabric apply. XIII. ERECTION Fence to be installed by skilled and experienced fence erectors and on lines and grades furnished by owner. All line posts to be set in concrete founda- tion a minimum of 9" diameter and a minimum of 30" deep. Gate posts shall be set in concrete foundation a minimum of 3 times the diameter of the post 1-2-4 concrete mixture. - 2 - PROPOSED CHAIN LINK FENCE LUBBOCK, TEXAS 3125183 N.E.B. /"= 60' DWG. NO. SD - 0001 - 9-033183 DATE DRAWN APPROVED SCALE SECTION_CORNER �: f SECTION LINE N 89040'E (I I/Z PIPE i 160' so. 0 37.5' 260�. X .. — X— —it 89055 9CP05' a _ I PROPOSED GATE S x EXISTING I I CITY WELL I NO. 32 I 3 o� z I 44 X J PROPOSED I CHAIN LINK FENCE NORMPROPOSED GATE I p C W 11500638" a cn i X • = EXISTING 1/2" REBAR x �X gi, _ 6405922" X/ Y / x RESOLUTION 4491 5/12/83 Cal T Y RFTARY-TREASURER IDGV:cl I IBE IT RESOLVED BY THE CITY COUNCIL OF THE CI' THAT the Mayor of the City of Lubbock B: directed to execute for and on behalf of the !Cyclone Fence Sales for a substation fence, , I9-033183, pursuant to Bid Number 7349, said (between said City as the prospective owner ai contractor for such construction. The state. $8,260.00, attached herewith which shall be Council and as spread upon the minutes of th a part of this Resolution as if fully copied (Passed by the City Council this 12th day o ALAW HE ATTEST: ti Evelyn Ga ga, City Secr ary-Treasurer APPROVED AS TO CONTENT: C Carroll McDonald, Director of Electric Utilities APPROVED AS TO FORM: . D&r Vandiv%f, First. Assistant City Attorney RESOLUTION 139 1- 5/12/83 CONTRACT AGREEMENT (EQUIPMENT) THIS AGREEMENT, made and entered into this 12th day of May 19 83 , by and between The City of Lubbock, Texas acting through its Mayor and City Council thereunto duly authorized so to do, Party of the First Part, and hereinafter called the Purchaser, and _ Cyclone Fence Sales , a corporation of Texas Party of the Second Part, and hereinafter called the Contractor. WITNESSETH: THAT WHEREAS, the Purchaser has caused to be prepared, in accordance with law, specifications, plans, and other contract documents for the work herein described, and has approved and adopted said documents, and has caused to be published, in the manner and for the time required by law, an advertisement for and in connection with acquiring Substation Fence in accordance with the terms of this Contract; and WHEREAS, the said Contractor, in response to such advertisement, has submitted to the Purchaser, in the manner and at the time specified, a sealed proposal in accordance with the terms of said advertisement; and WHEREAS, the Purchaser, in the manner prescribed by law, has publicly opened, examined, and canvassed the proposals submitted in response to the published invitation therefor, and as a result of such canvass has determined and declared the aforesaid Contractor to be the best bidder for the said work and has duly awarded to the said Contractor a contract therefor, for the sum or sums named in the Contractor's proposal, a copy thereof being attached to and made a part of this Contract. NOW THEREFORE, in consideration of the compensation to be paid to the Contractor and of the mutual agreements herein contained, the Parties to these presents have agreed and hereby agree, the Purchaser for itself and its successors, and the Contractor for itself, himself, or themselves, or its, his, or their successors and assigns, or its, his, or their executors and administrators, as follows: ARTICLE I. That the Contractor shall (a) Furnish all materials, supplies, and equipment specified and required to be incorporated in and'form a permanent part of the completed work; (b) Provide and perform all necessary work; and, in a good, substantial, and workmanlike manner and in accordance with the provisions of the General Conditions, and the Instructions to Bidders, (which are attached hereto and made a part hereof) and in conformity with the Specifications Number SE-0001-9-033183 (c) Execute and complete all work included in and covered by the Purchaser's official award of this Contract to the said Contractor, such award being based on the acceptance by the Purchaser of the Contractor's proposal, or part thereof, as follows: Substation Fence ARTICLE II. That the Purchaser shall pay to the Contractor for the }yerformance of the work embraced in this Contract, and the Contractor will accept as full compensation therfor, the sum (subject to adjustment as pro- vided by the Contract) of _Eight thousand two hundred sixty dollars ($ 8.260.00 ) for all work covered by and included in the Contract award and designated in the foregoing Article I. ARTICLE III.- The Contractor shall proceed with the work to be performed under the provisions of.this Contract on, or within ten (10) days following, the date of public acceptance of the Contractor's proposal by the Purchaser. Contractor shall not delay the start of the work to be performed under the provisions of this Contract except by written order from the Purchaser. Contractor shall complete said work by. July 1st, 1983 IN WITNESS -WHEREOF, the Parties hereto have executed this. Contract as of day and year first written. CITY OF LUBBOCK BY: ATTEST: Evelyn Ga fga, City S c ary-Treasurer APPROVED AS TO CONTENT: G� �i�"lc�lCic� APPROVED AS TO FORM: I}ONA G..VANDIVER,--Assistant City -Attorney PARTY OF THE SECOND PART (CONTRACTOR) BY: ATTEST: Signature of Officer CO-21thcrI mew 14 A.'uA, G6-2t Secretary Title NOTE: This Contract must be signed by the President or Vice President of the Contractor's firm and attested by the Secretary of the firm. If the Contract is to be signed by any person other than the President or lice President, then a Board Resolution authorizing said person to sign and bind the firm must be included with each copy of the Contract. i, Donald C. Anderson , Assistant Secretary of United States Steel Corporation, a Delaware corporation, do hereby certify that the following is a true and correct copy of a resolution adopted by the Corporate Policy Committee of said United States Steel Corporation on the 22nd day of December, 1980,.and that said resolution is in full force and effect at this date: RESOLVED: That the Managing Director and any Sales Manager of Manufactured Wire Products; the General Manager of Electrical Cable; the General Manager and any Manager -Sales, Area Sales Manager, Sales Representative and Service Representative of Wire Rope; the General Manager, the Manager and any Sales, District, Assistant District and Contracting Manager of Cyclone Fence, be, and each of them hereby is, authorized and empowered for and on behalf of this Corporation to execute any and all tenders, proposals, order acceptances, contracts and other documents relating to the sale of products or services of this Corporation within their respective commercial responsibilities. Witness my hand and seal of the Corporation this day of 19 Assistant Secretary STANDARD CHAIN LINK FENCE SPECIFICATIONS 9 1. STYLE FENCE Chain link fence with three strands of barbed wire on 450 extension arms. Fence to be nine (9) feet high overall when erected. 11. FABRIC Steel wire to be ninety-six (96) inches high, #9 gauge woven in a two (2) inch mesh with barbed selvages top and bottom. The wire pickets shall stand a minimum tensile strength of 80,000 PSI based on a cross sectional area of wire. 111. PROTECTIVE COATING The chain link fabric shall be either galvanized after weaving or aluminum coated. Galvanizing shall be 2 oz. per sq. ft. of area in accordance with ASTM A392 Class II. Aluminum coating shall be .40 oz. per sq. ft. of area in accordance with ASTM A491-63-T. IV. BOTTOM TENSION WIRE S BARBED WIRE Steel barbed wire to be of 4 point pattern composed of two strands of 121 ^, gauge line wires with 14 gauge barbs spaced on approximately five (5) inch centers. Bottom tension wire shall be No. 7 gauge spring coil tension wire, fastened to chain link fabric with No. 11 gauge hog rings on twenty-four (24) inch centers. Coating shall match coating of fabric furnished. V. TOP RAIL 1-5/8" OD Schedule 40 galvanized pipe, or 1-5/8" x 4" galvanized roll section. Fabric to be tied to top rail every 24" with #i9 gauge aluminum tie wires. VI. BRACES Same material as top rail and trussed from line post back to terminal post with 3/8" galvanized rod complete with truss tightener. VII. LINE POSTS Galvanized Hi Carbon 1.875" H-Column or 2-3/8" OD Schedule 40 pipe, spaced on centers not to exceed ten (10) feet. Post equipped with #6 gauge gal- vanized clips on- fourteen (14) inch centers. EXTENSION ARMS Line post extension arms to withstand a minimum pull down weight of 450 lbs. from end of arm and are to be made of pressed steel or malleable iron base - 1 - with pressed steel extension riveted and galvanized after assembly. Y IX. TERMINAL POSTS End, corner, and pull posts to be 2-7/8" OD Schedule 40 galvanized pipe, or 3}" x 31" galvanized roll formed section. Fabric to be attached to terminal posts by use of 4" x 3/4" tension bars laced to post every 14" with•11 gauge 1" wide steel bands and 3/8" diameter bolts and nuts, or by integrally weav- ing wire to post in formed lock loops. Pipe posts -to have cast iron or pressed steel top of manufacturer's standard design. X. GATE POSTS Maximum opening 6' single or 12' double - 277/8" OD Schedule 40 galvanized pipe, or 31" x 31" galvanized roll section. Maximum opening 12' single or 24' double - 4" OD galvanized pipe weight 9.11# per ft. Maximum opening 18' single or 36' double - 6-5/8" OD galvanized pipe weight 18.97# per ft. Over 18' single or 36' double - 8-5/8" OD galvanized pipe weight. XI. GATES Frame to be 2" OD galvanized pipe with pressed steel or malleable .iron corner ells riveted with 4 rivets per corner. Internal bracing shall be 1-3/8" OD pipe with 3/8" adjustable truss rods. Gate shall be complete with padlocking device, center rest and semi -automatic catch to secure drive gate in open position. XII. TOLERANCE Standard Mill Tolerances on all framework members and chainilink fabric apply. XIII. ERECTION Fence to be installed by skilled and experienced fence erectors and on lines and grades furnished by owner. All line posts to be set in concrete founda- tion a minimum of 9" diameter and a minimum of 30" deep. Gate posts shall be set in concrete foundation a minimum of 3 times the diameter of the post 1-2-4 concrete mixture. 2 - ` Mr— 00001/41 IVIN PROPOSED CHAIN LINK FENCE LUWlUU rr% rvYVCli Cl LIU r LUBBOCK, TEXAS 3125163 N.E.B. 1 = 60 DWG. NO. SD — 0001 — 9—033183 DATE DRAWN APPROVED SCALE SECTIQN CORNER SECTION LINE N 89040'E ( 1 1/2� PIPE) 160� 0 -- X -- X X' .. — X — X-11 x890 55' 90°05� a I � PROPOSED GATE ( x EXISTING CITY WELL IX NO. 32 I I ti X oS X 44 I (—PROPOSED CHAIN LINK FENCE NORTH PROPOSED GATE �'i1 X c I 11500C 38" aoc-i Iiir X • o EXISTING 1/2" RESAR x /X / X• 2e6 '` eFVk x 64059�22" X� .(0711 NOTICE TO BIDDERS Sealed proposals addressed to Gene Eads, Director of Purchasing, City of Lubbock, Texas, will be received at the office of the Purchasing Agent until 4:00 P.M. on April 25, 1983 , for furnishing and installing all necessary materials, machinery, equipment, superintendence, and labor for construction of a substation fence in accordance with the attached specifications. The City Council will consider bids on May 12, 1983 at the City Hall, subject to the right to reject any or all bids and to waive formalities. Bids may not be withdrawn after they are submitted. Bidders are required to submit a cashier's or certified check or bid bond in the amount of 5% of the total bid and the successful bidder shall provide bond in the full amount of the contract price executed by a surety company authorized to do business in Texas. CITY OF LUBBOCK, TEXAS M. Gene Eads Director of Purchasing CERTIFICATE OF INSURANCE TO: CITY OF LUBBOCK Date Type of Lubbock, Texas Project: THIS IS TO CERTIFY THAT (Name and Address of Insured) is, at the date of this certificate, insured by this Company with respect to the business operations hereinafter described, for the types of insurance and in accordance with the provisions of the standard policies used by this Company, and further hereinafter des- cribed. Exceptions to standard policy noted on reverse side hereof. ' TYPE OF INSURANCE ,. Policy No. Effective Expires Limits of Liability Workmen's Compensation Contractor's Protec- 1 person $ tive Contingent 1 accident $ Liability Property Damage $ Builder's . Risk Automobile 1 person $ 1 accident $ Other Property Damage $ The foregoing Policies (do) (do not) cover all sub -contractors. 'Locations Covered: DESCRIPTIO14 of Operations Covered The above policies either _in the body thereof or by appropriate endorsement provide that they nay not be changed or cancelled by the insurer' in less than the legal time required after the insured has received written notice of such change or cancellation, or in case there is no legal requirement, in less than five days after the insured has received such written notice. FIVE COPIES OF THIS CERTIFICATE. MUST En SENT TO THE OWNER By Title (Name of insurer) TABLE OF CONTENTS Notice To Bidders Certificate of Insurance Contract Agreement Specifications P. 0. Box 5466 USS Cyclone Fence Arlington, Texas 76011 VWUd IWa SW cffpr" [ 817 ] 261-6206 TOj City of Lubbock Purchasing Department P. 0. Box 2000 Lubbock, Texas 79457 sUBJECTs Lubbock Power & Light Sub Station Please process/review the enclosed item[s] [ ] Proposal [ ] Proposal for your signature [ ] Confirmation of verbal Quotation [ ] Confirmation of your verbal order [ ] Confirmation of your Purchase Order No, ( ] Acknowledgement copy of your P.O. No. [XM Signed contracts and insurance REMARKSs Yours truly, Eddie Cromwell cc$ [ ] CycloneTM General Catalog [ ] Aluminum Coated Fabric Data [ ] CycloneTM Drawings] [ ] Electric Gate Operator Data We want to work for you. LTerminal Post I Line Post C Line Post C Line Post 13 Rail , NAME AND ADDRESS OF AGENCY COMPANIES AFFORDING ,.,,}1�� LpE`-�� ^ LJ1 11�'.,/ Marsh 6 •McLennan, Inc. COVERAGES t./ V Suite 5500 COMPANY %� LETTER A Employers Casualty Company 600 Grant Street COMPANY LETTER B Insurance Company of North America Pittsburgh, PA 15219 NAME ANq ADDRESS OF INSURED e Cyclone Fence COMPANY LETTER Manufactured Wire Products Division United States Steel Corporation PA ETtER"Y Post Office Box 7310 Chicago, Illinois 60680 LEETTERNY E This is to certify that policies of insurance listed below have been Issued to the insured named above and are in force at this time. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms_ exclusions and conditions of such policies. Limits o L a it n Thousands COMPANY LETTER TYPE OF INSURANCE POLICY NUMBER POLICY EXPIRATION DATE EACH OCCURRENCE -AGGREGATE GENERAL LIABILITY BODILY INJURY s s A ®COMPREHENSIVE FORM CGL 573881 5/l/86 EIPREMISES—OPERATIONS PROPERTY DAMAGE s Z: ' ®EXPLOSION AND COLLAPSE. HAZARD ® UNDERGROUND HAZARD ® PRODUCTS/COMPLETED OPERATIONS HAZARD ® CONTRACTUAL INSURANCE -. BODILY INJURY AND PROPERTY DAMAGE s5,000 s5,000 BROAD FORM PROPERTY COMBINED DAMAGE ® INDEPENDENT CONTRACTORS _ PERSONAL INJURY $ S , OOO - ® PERSONAL INJURY AUTOMOBILE LIABILITY BODILY INJURY $ - B ® SRL 706 5/l/86 (EACH PERSON) COMPREHENSIVE FORM BODILY INJURY $ ® (EACH ACCIDENT) OWNED PROPERTY DAMAGE S ® HIRED BODILY INJURY AND ® NON -OWNED PROPERTY DAMAGE $ 5,000 COMBINED EXCESS LIABILITY BODILY INJURY AND ❑ UMBRELLA FORM PROPERTY DAMAGE s $ ❑ OTHER THAN UMBRELLA COMBINED FORM WORKERS' COMPENSATION Various STATUTORY A and Idaho, New Mexico, Texas l/l/86 : 100 EMPLOYERS' LIABILITY tCACN.COOIN OTHER DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES ± Cyclone Office Location: Fort Worth furnish and install chain link fencing at Lubbock Power and Light Substation, Municipal Drive & Guava St., Lubbock, Tx., USS#519-3-00246 Cancellation:- Should any of the above described policies be cancelled before the expiration date thereof, the issuing com- pany will endeavor to mail P days written notice to the below named certificate holder, but failure to mail such notice shall impose no obligation or liability of any kind upon the company. NAME AND ADDRESS OF CERTIFICATE HOLDER: City of Lubbock L P. 0. Box 2000 Lubbock, Texas 79457 DATE ISSUED May 23 1983 AUTHORIZED REPRESENTATIVE ACORD 25 (1-79)